The influence of diffusion fluxes on the detection limit of the jalpaite copper ion-selective electrode

被引:0
|
作者
Zirino, A
De Marco, R
Rivera, I
Pejcic, B
机构
[1] Curtin Univ Technol, Sch Appl Chem, Perth, WA 6845, Australia
[2] SPAWAR Syst Ctr, San Diego, CA 95152 USA
关键词
copper ion-selective electrode; rotating disk electrode; electrode dissolution; diffusion flux; seawater;
D O I
10.1002/1521-4109(200204)14:7/8<493::AID-ELAN493>3.0.CO;2-C
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It has been suggested that electrode dissolution and the concomitant saturation of the electrode's diffusion layer restricts the detection limit of the jalpaite Cu ion-selective electrode (ISE) to samples with total Cu levels above 10(-6) mol dm(-3) [1, 2]. This article will use rotating disk electrode (RDE) data for San Diego Bay seawater and Fick's law of diffusion to demonstrate that the static commercial Orion Cu ISE (employing a jalpaite membrane) produces a background level of contamination of (2.0 +/- 0.5) x 10(-8) mol dm(-3) total Cu, and the reduced thickness of the Orion Cu ISE's diffusion layer in the presence of hydrodynamic flow [e.g., at an RDE, or in continuous flow analysis (CFA)] lowers the background contamination of Cu to <10(-9) mol dm(-3). Furthermore, the RDE Cu ISE employing an electrode fabricated using jalpaite precipitated in 80% excess Na2S, so as to minimize the presence of occluded and leachable Cu2+ salts and extraneous phases such as silver sulfide [3 - 5], reveals an improvement in the lower limit of detection compared to the commercial Orion Cu ISE.
引用
收藏
页码:493 / 498
页数:6
相关论文
共 50 条
  • [21] ION-SELECTIVE ELECTRODE
    KARSELIS, TC
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1979, 71 (04) : 481 - 481
  • [22] Detection of Bromide Ions in Water Samples with a Nanomolar Detection Limit using a Potentiometric Ion-selective Electrode
    Kou, Lijuan
    Liang, Rongning
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (02): : 1601 - 1609
  • [23] Lowering the detection limit of solvent polymeric ion-selective electrodes. 1. Modeling the influence of steady-state ion fluxes
    Sokalski, T
    Zwickl, T
    Bakker, E
    Pretsch, E
    ANALYTICAL CHEMISTRY, 1999, 71 (06) : 1204 - 1209
  • [24] DETERMINATION OF COPPER IN WATER BY MEANS OF CHALCOCITE COPPER ION-SELECTIVE ELECTRODE
    HULANICKI, A
    TROJANOWICZ, M
    KRAWCZYK, TKV
    WATER RESEARCH, 1977, 11 (08) : 627 - 630
  • [25] DETERMINATION OF COPPER IN TECHNICAL ZINC ELECTROLYTE WITH THE COPPER ION-SELECTIVE ELECTRODE
    GEISSLER, M
    KUNZE, R
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1984, 318 (01): : 15 - 18
  • [26] ION-SELECTIVE ELECTRODE POTENTIOMETRIC DETECTION IN ION-CHROMATOGRAPHY
    ISILDAK, I
    COVINGTON, AK
    ELECTROANALYSIS, 1993, 5 (9-10) : 815 - 824
  • [27] ION-SELECTIVE ELECTRODE FOR THE DETECTION OF COBALT IN CYANIDE SOLUTIONS
    PADARAUSKAS, AV
    KAZLAUSKAS, RM
    PETRUKHIN, OM
    KAREIVA, AA
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII KHIMIYA I KHIMICHESKAYA TEKHNOLOGIYA, 1989, 32 (02): : 47 - 50
  • [28] LEAD POISONING IN CHILDREN - DETECTION BY ION-SELECTIVE ELECTRODE
    RECHNITZ, GA
    SCIENCE, 1969, 166 (3904) : 532 - &
  • [29] Development and Optimization of an Ion-selective Electrode for Serotonin Detection
    Bliem, Christina
    Fruhmann, Philipp
    Stoica, Anca-Iulia
    Kleber, Christoph
    ELECTROANALYSIS, 2017, 29 (06) : 1635 - 1642
  • [30] ION-SELECTIVE ELECTRODE STUDY OF COPPER(I) COMPLEXES IN ACETONITRILE
    HEERMAN, LF
    RECHNITZ, GA
    ANALYTICAL CHEMISTRY, 1972, 44 (09) : 1655 - &