The influence of diffusion fluxes on the detection limit of the jalpaite copper ion-selective electrode

被引:0
|
作者
Zirino, A
De Marco, R
Rivera, I
Pejcic, B
机构
[1] Curtin Univ Technol, Sch Appl Chem, Perth, WA 6845, Australia
[2] SPAWAR Syst Ctr, San Diego, CA 95152 USA
关键词
copper ion-selective electrode; rotating disk electrode; electrode dissolution; diffusion flux; seawater;
D O I
10.1002/1521-4109(200204)14:7/8<493::AID-ELAN493>3.0.CO;2-C
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It has been suggested that electrode dissolution and the concomitant saturation of the electrode's diffusion layer restricts the detection limit of the jalpaite Cu ion-selective electrode (ISE) to samples with total Cu levels above 10(-6) mol dm(-3) [1, 2]. This article will use rotating disk electrode (RDE) data for San Diego Bay seawater and Fick's law of diffusion to demonstrate that the static commercial Orion Cu ISE (employing a jalpaite membrane) produces a background level of contamination of (2.0 +/- 0.5) x 10(-8) mol dm(-3) total Cu, and the reduced thickness of the Orion Cu ISE's diffusion layer in the presence of hydrodynamic flow [e.g., at an RDE, or in continuous flow analysis (CFA)] lowers the background contamination of Cu to <10(-9) mol dm(-3). Furthermore, the RDE Cu ISE employing an electrode fabricated using jalpaite precipitated in 80% excess Na2S, so as to minimize the presence of occluded and leachable Cu2+ salts and extraneous phases such as silver sulfide [3 - 5], reveals an improvement in the lower limit of detection compared to the commercial Orion Cu ISE.
引用
收藏
页码:493 / 498
页数:6
相关论文
共 50 条
  • [1] Response of the jalpaite membrane copper(II) ion-selective electrode in marine waters
    DeMarco, R
    Mackey, DJ
    Zirino, A
    ELECTROANALYSIS, 1997, 9 (04) : 330 - 334
  • [2] Surface studies of the jalpaite-based copper(II) ion-selective electrode membrane in seawater
    School of Applied Chemistry, Curtin University of Technology, G.P.O. Box U 1987, Perth, WA 6001, Australia
    MAR. CHEM., 1600, 3-4 (389-398):
  • [3] Surface studies of the jalpaite-based copper(II) ion-selective electrode membrane in seawater
    DeMarco, R
    MARINE CHEMISTRY, 1996, 55 (3-4) : 389 - 398
  • [4] DETECTION LIMIT OF ORION IODIDE-SILVER ION-SELECTIVE ELECTRODE
    KONTOYANNAKOS, J
    MOODY, GJ
    THOMAS, JDR
    ANALYTICA CHIMICA ACTA, 1976, 85 (01) : 47 - 53
  • [5] ION-SELECTIVE MEMBRANE ELECTRODE FOR COPPER (II)
    PICK, J
    KEMIAI KOZLEMENYEK, 1973, 39 (01): : 19 - 33
  • [6] ION-SELECTIVE ELECTRODE TO DETERMINE COPPER(I)
    KHOLMOVOI, YP
    PETRUKHIN, OM
    RUB, LM
    ANNAPOLSKII, VI
    INDUSTRIAL LABORATORY, 1983, 49 (06): : 563 - 566
  • [7] A new approach for decreasing the detection limit for a ketamine(I) ion-selective electrode
    Abu Shawish, Hazem M.
    Tamous, Hassan
    Saadeh, Salman M.
    Abed-Almonem, Khalid I.
    Al Khalili, Osama
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 49 : 445 - 451
  • [8] DETECTION LIMIT OF PRECIPITATE-BASED CU(II) ION-SELECTIVE ELECTRODE
    UMEZAWA, Y
    UEMASU, I
    WATANABE, M
    DENKI KAGAKU, 1982, 50 (01): : 109 - 110
  • [9] INVESTIGATION OF A COPPER ION-SELECTIVE MEMBRANE ELECTRODE
    SAVVIN, NI
    SHTERMAN, VS
    SYRCHENK.AY
    GORDIEVS.AV
    INDUSTRIAL LABORATORY, 1971, 37 (09): : 1297 - &
  • [10] Direct measurement of Cu(II)aq in seawater at pH 8 with the jalpaite ion-selective electrode
    Zirino, A
    VanderWeele, DA
    Belli, SL
    DeMarco, R
    Mackey, DJ
    MARINE CHEMISTRY, 1998, 61 (3-4) : 173 - 184