摘要
Mathematical model for evaluation of the multilayer heterogeneous biocatalytic system has been elaborated. The model consists of nonlinear system of partial differential equations with initial values and boundary conditions. An algorithm for computing the numerical solution of the mathematical model has been applied. Two cases: when product diffuses out of the biosensor and when the outer membrane is impermeable for product (product is trapped inside the biosensor) have been dealt with by adjusting boundary conditions in the mathematical model. Profiles of the impact of the substrate and product degradation rates on the biosensor response have been constructed in both cases. Value of the degradation impact has been analyzed as a function of the outer membrane thickness. The initial substrate concentration also affects influence of the degradation rates on the biosensor response. Analytical formulae, defining approximate values of relationships between the degradation rates and the outer membrane thickness or the initial substrate concentration, have been obtained. These formulae can be employed for monitoring of the biosensor response.
引用
收藏
页码:2491 / 2502
页数:12
相关论文
共 13 条
[1]   Computational modelling of the behaviour of potentiometric membrane biosensors [J].
Baronas, R. ;
Ivanauskas, F. ;
Kulys, J. .
JOURNAL OF MATHEMATICAL CHEMISTRY, 2007, 42 (03) :321-336
[2]   Modelling amperometric enzyme electrode with substrate cyclic conversion [J].
Baronas, R ;
Kulys, J ;
Ivanauskas, F .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (08) :915-922
[3]   Modelling of amperometric biosensors with rough surface of the enzyme membrane [J].
Baronas, R ;
Ivanauskas, F ;
Kulys, J ;
Sapagovas, M .
JOURNAL OF MATHEMATICAL CHEMISTRY, 2003, 34 (3-4) :227-242
[4]   Modelling dynamics of amperometric biosensors in batch and flow injection analysis [J].
Baronas, R ;
Ivanauskas, F ;
Kulys, J .
JOURNAL OF MATHEMATICAL CHEMISTRY, 2002, 32 (02) :225-237
[5]  
Baronas R, 2010, SPRINGER SER CHEM SE, V9, P9, DOI 10.1007/978-90-481-3243-0_2
[6]  
Britz D., 2005, LECT NOTES PHYS, V666
[7]   Functionalization of poly-SNS-anchored carboxylic acid with Lys and PAMAM: surface modifications for biomolecule immobilization/stabilization and bio-sensing applications [J].
Demirci, Sema ;
Emre, Fatma Bilge ;
Ekiz, Fulya ;
Oguzkaya, Funda ;
Timur, Suna ;
Tanyeli, Cihangir ;
Toppare, Levent .
ANALYST, 2012, 137 (18) :4254-4261
[8]  
Fraser D.M, 1997, Wiley Series in Biomaterials Science and Engineering
[9]  
LAURINAVICIUS VA, 1989, BIOMED BIOCHIM ACTA, V48, P905
[10]   Cauliflower polyaniline/multiwalled carbon nanotube electrode and its applications to hydrogen peroxide and glucose detection [J].
Poorahong, Sujittra ;
Thammakhet, Chongdee ;
Thavarungkul, Panote ;
Kanatharana, Proespichaya .
PURE AND APPLIED CHEMISTRY, 2012, 84 (10) :2055-2063