A robust image analysis technique for the study of horizontal air-water plug flow

被引:21
|
作者
Kong, Ran [1 ]
Rau, Adam [2 ]
Kim, Seungjin [1 ]
Bajorek, Stephen [3 ]
Tien, Kirk [3 ]
Hoxie, Chris [3 ]
机构
[1] Purdue Univ, Sch Nucl Engn, Nucl Engn Bldg,400 Cent Dr, W Lafayette, IN 47907 USA
[2] Penn State Univ, Dept Mech & Nucl Engn, Reber Bldg, University Pk, PA 16082 USA
[3] US Nucl Regulatory Commiss, 11555 Rockville Pike, Rockville, MD 20852 USA
关键词
Image analysis; Horizontal plug flow; Interface detection; Interface tracking; Bubble segmentation; Plug bubble reconstruction; 2-PHASE FLOW; CONDUCTIVITY PROBE; PROCESSING TECHNIQUE; TRANSITION; SENSITIVITY; PIPES;
D O I
10.1016/j.expthermflusci.2018.12.001
中图分类号
O414.1 [热力学];
学科分类号
摘要
The current work develops a robust image analysis technique for quantitative measurements in horizontal plug flow. To do this, experiments are performed to capture high-speed videos for horizontal air-water plug flow for two test conditions in a 38.1 mm ID pipe. A visualization block-mirror system is designed and fabricated to allow the simultaneous visualization of two-phase flow from both top and side views using a single camera. To obtain images of high quality for analysis, the angle and position of the camera relative to the visualization block are verified. With the obtained images, an algorithm is developed to detect and track the interface of plug bubbles. Due to the existence of contacting or overlapping small bubbles, additional algorithms are developed to segment the interfaces of plug bubble from those of small bubbles, including distance checking, interface breakpoints detection, and convex curvature segmentation. As a result, the nose position, local time-averaged axial velocity, and area-averaged time-averaged void fraction for plug bubbles can be obtained with this newly developed image analysis technique. To benchmark the newly developed image analysis code, local four-sensor conductivity probe measurements are performed. The axial velocity for plug bubbles generally agrees within +/- 10% between image analysis technique and the four-sensor conductivity probe measurement technique, while the plug bubble reconstruction approach can generate an area-averaged void fraction within +/- 10% of the probe measured value.
引用
收藏
页码:245 / 260
页数:16
相关论文
共 50 条
  • [22] Experimental study on air-water countercurrent flow limitation in horizontal pipes with different types of obstructions
    Zhu, Xixi
    Xu, Chende
    Gu, Mingzhou
    Tang, Shuai
    Wang, Naihua
    PROGRESS IN NUCLEAR ENERGY, 2024, 169
  • [23] Analysis of air-water flow pattern in parallel microchannels: A visualization study
    Barreto, E. X.
    Oliveira, J. L. G.
    Passos, J. C.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2015, 63 : 1 - 8
  • [24] Flow disturbances induced by an orifice plate in a horizontal air-water flow in the slug regime
    Maidana, Nathan da Costa
    Rosa, Eugenio Spano
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2018, 94 : 59 - 76
  • [25] Visualization Study in the Transition Flow Pattern of Stratified to Slug Flow of Air-Water Two Phase Flow in a Horizontal Pipe
    Rahmandhika, Andinusa
    Dinaryanto, Okto
    Widyatama, Arif
    Hudaya, Akhmad Zidni
    Indarto
    Deendarlianto
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON THERMOFLUIDS 2017 (THERMOFLUID 2017), 2018, 2001
  • [26] Experimental Study on The Characteristics of Flow Pattern Transitions of Air-Water Two-Phase Flow in A Horizontal Pipe
    Humami, Faris
    Dinaryanto, Okto
    Hudaya, Aldunad Zidni
    Widyatama, Arif
    Indarto
    Deendarlianto
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON THERMOFLUIDS 2017 (THERMOFLUID 2017), 2018, 2001
  • [27] Fluctuation of air-water two-phase flow in horizontal and inclined water pipelines
    Kabiri-Samani, A. R.
    Borghei, S. M.
    Saidi, M. H.
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2007, 129 (01): : 1 - 14
  • [28] Measurement technique for air-water disperse system study
    Ciocan, G.D., 1600, Politechnica University of Bucharest, Splaiul Independentei 313 - Sector 6, Bucharest, 77206, Romania (74):
  • [29] HEAT-TRANSFER TO AIR WATER PLUG SLUG FLOW IN HORIZONTAL PIPES
    DESHPANDE, SD
    BISHOP, AA
    KARANDIKAR, BM
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1991, 30 (09) : 2172 - 2180
  • [30] DETERMINING AVERAGE HOLDUP AND PHASE-VELOCITY IN A HORIZONTAL AIR-WATER FLOW
    EBNER, L
    WIEDEMANN, K
    ZAHRADNIK, J
    DRAHOS, J
    CHEMISCHE TECHNIK, 1988, 40 (07): : 314 - 314