Quantitative analysis of the breath-holding half-Fourier acquisition single-shot turbo spin-echo technique in abdominal MRI

被引:0
作者
Dong, Kyung-Rae [1 ,2 ]
Goo, Eun-Hoe [3 ]
Lee, Jae-Seung [4 ]
Chung, Woon-Kwan [2 ]
机构
[1] Gwangju Hlth Coll Univ, Dept Radiol Technol, Kwangju 501701, South Korea
[2] Chosun Univ, Dept Nucl Engn, Kwangju 501759, South Korea
[3] Cheong Ju Univ, Dept Radiol Sci, Chonju 360764, South Korea
[4] Dong Eui Univ, Dept Radiol Sci, Pusan 614714, South Korea
关键词
HASTE; Hepatobiliary tract; MIP; MRI; SEQUENCE; LIVER; MRCP; CHOLANGIOGRAPHY; ERCP;
D O I
10.3938/jkps.62.350
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A consecutive series of 50 patients (28 males and 22 females) who underwent hepatic magnetic resonance imaging (MRI) from August to December 2011 were enrolled in this study. The appropriate parameters for abdominal MRI scans were determined by comparing the images (TE = 90 and 128 msec) produced using the half-Fourier acquisition single-shot turbo spin-echo (HASTE) technique at different signal acquisition times. The patients consisted of 15 normal patients, 25 patients with a hepatoma and 10 patients with a hemangioma. The TE in a single patient was set to either 90 msec or 128 msec. This was followed by measurements using the four normal rendering methods of the biliary tract system and the background signal intensity using the maximal signal intensity techniques in the liver, spleen, pancreas, gallbladder, fat, muscles and hemangioma. The signal-to-noise and the contrast-to-noise ratios were obtained. The image quality was assessed subjectively, and the results were compared. The signal-to-noise and the contrast-to-noise ratios were significantly higher at TE = 128 msec than at TE = 90 when diseases of the liver, spleen, pancreas, gallbladder, and fat and muscles, hepatocellular carcinomas and hemangiomas, and rendering the hepatobiliary tract system based on the maximum signal intensity technique were involved (p < 0.05). In addition, the presence of artifacts, the image clarity and the overall image quality were excellent at TE = 128 msec (p < 0.05). In abdominal MRI, the breath-hold half-Fourier acquisition single-shot turbo spin-echo (HASTE) was found to be effective in illustrating the abdominal organs for TE = 128 msec. Overall, the image quality at TE = 128 msec was better than that at TE = 90 msec due to the improved signal-to-noise (SNR) and contrast-to-noise (CNR) ratios. Overall, the HASTE technique for abdominal MRI based on a high-magnetic field (3.0 T) at a TE of 128 msec can provide useful data.
引用
收藏
页码:350 / 357
页数:8
相关论文
共 37 条
  • [31] Can a single-shot black-blood T2-weighted spin-echo echo-planar imaging sequence with sensitivity encoding replace the respiratory-triggered turbo spin-echo sequence for the liver? An optimization and feasibility study
    Hussain, SM
    De Becker, J
    Hop, WCJ
    Dwarkasing, S
    Wielopolski, PA
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (03) : 219 - 229
  • [32] Comparison of DWI Methods in the Pediatric Brain: PROPELLER Turbo Spin-Echo Imaging Versus Readout-Segmented Echo-Planar Imaging Versus Single-Shot Echo-Planar Imaging
    Kim, Tae-Hyung
    Baek, Moon-Young
    Park, Ji Eun
    Ryu, Young Jin
    Cheon, Jung-Eun
    Kim, In-One
    Choi, Young Hun
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (06) : 1352 - 1358
  • [33] Accurate brain volumetry with diffusion-weighted spin-echo single-shot echo-planar-imaging and dual-clustering segmentation: Comparison with volumetry-validated quantitative magnetic resonance imaging
    Watanabe, Memi
    Sakai, Osamu
    Norbash, Alexander M.
    Jara, Hernan
    MEDICAL PHYSICS, 2010, 37 (03) : 1183 - 1190
  • [34] Breath-hold black blood quantitative T1rho imaging of liver using single shot fast spin echo acquisition
    Chen, Weitian
    Chan, Queenie
    Wang, Yi-Xiang J.
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2016, 6 (02) : 168 - 177
  • [35] Turbo Spin-echo Diffusion-weighted Imaging Compared with Single-shot Echo-planar Diffusion-weighted Imaging: Image Quality and Diagnostic Performance When Differentiating between Ductal Carcinoma in situ and Invasive Ductal Carcinoma
    Mori, Naoko
    Mugikura, Shunji
    Miyashita, Minoru
    Mori, Yu
    Maekawa, Yui
    Nagasaka, Tatsuo
    Takase, Kei
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2021, 20 (01) : 60 - 68
  • [36] Clinical feasibility of an abdominal thin-slice breath-hold single-shot fast spin echo sequence processed using a deep learning-based noise-reduction approach
    Tajima, Taku
    Akai, Hiroyuki
    Yasaka, Koichiro
    Kunimatsu, Akira
    Akahane, Masaaki
    Yoshioka, Naoki
    Abe, Osamu
    Ohtomo, Kuni
    Kiryu, Shigeru
    MAGNETIC RESONANCE IMAGING, 2022, 90 : 76 - 83
  • [37] Hepatic malignant tumour versus cavernous haemangioma: Differentiation on multiple breath-hold turbo spin-echo MRI sequences with different T2-weighting and T2-relaxation time measurements on a single slice multi-echo sequence
    Chan, YL
    Lee, SF
    Yu, SCH
    Lai, P
    Ching, ASC