Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

被引:7
作者
Lundqvist, Eva [1 ]
Segelsjo, Monica [1 ]
Andersson, Anna [2 ]
Magnusson, Anders [1 ]
Biglarnia, Ali-Reza [2 ]
机构
[1] Uppsala Univ, Dept Radiol Oncol & Radiat Sci, Sect Radiol, Uppsala, Sweden
[2] Univ Uppsala Hosp, Dept Surg Sci, Sect Transplantat Surg, Uppsala, Sweden
关键词
Computed tomography; volumetry; pancreas transplantation; observer variation; contrast media; KIDNEY; LIVER;
D O I
10.1258/ar.2012.120317
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose: To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods: CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results: The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion: CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume.
引用
收藏
页码:966 / 972
页数:7
相关论文
共 50 条
  • [41] Inter-observer agreement in identifying traction bronchiectasis on computed tomography: its improvement with the use of the additional criteria for chronic fibrosing interstitial pneumonia
    Junya Tominaga
    Alexander A. Bankier
    Kyung Soo Lee
    Ann N. Leung
    Martine Remy-Jardin
    Masanori Akira
    Hiroaki Arakawa
    Phillip M. Boiselle
    Tomás Franquet
    Kiminori Fujimoto
    Pierre Alain Gevenois
    Jin Mo Goo
    Philippe A. Grenier
    Hiroto Hatabu
    Kazuya Ichikado
    Jung-Gi Im
    Takeshi Johkoh
    Ki-Nam Lee
    David A. Lynch
    Satoshi Noma
    Jae-Woo Song
    Fumikazu Sakai
    Yukihiko Sugiyama
    Japanese Journal of Radiology, 2019, 37 : 773 - 780
  • [42] Inter-observer agreement in identifying traction bronchiectasis on computed tomography: its improvement with the use of the additional criteria for chronic fibrosing interstitial pneumonia
    Tominaga, Junya
    Bankier, Alexander A.
    Lee, Kyung Soo
    Leung, Ann N.
    Remy-Jardin, Martine
    Akira, Masanori
    Arakawa, Hiroaki
    Boiselle, Phillip M.
    Franquet, Tomas
    Fujimoto, Kiminori
    Gevenois, Pierre Alain
    Goo, Jin Mo
    Grenier, Philippe A.
    Hatabu, Hiroto
    Ichikado, Kazuya
    Im, Jung-Gi
    Johkoh, Takeshi
    Lee, Ki-Nam
    Lynch, David A.
    Noma, Satoshi
    Song, Jae-Woo
    Sakai, Fumikazu
    Sugiyama, Yukihiko
    JAPANESE JOURNAL OF RADIOLOGY, 2019, 37 (11) : 773 - 780
  • [43] Intra- and interobserver variability in the measurements of abdominal aortic and common iliac artery diameter with computed tomography. The Tromso study
    Singh, K
    Jacobsen, BK
    Solberg, S
    Bonaa, KH
    Kumar, S
    Bajic, R
    Arnesen, E
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2003, 25 (05) : 399 - 407
  • [44] Reduction of inter-observer variability using MRI and CT fusion in delineating of primary tumor for radiotherapy in lung cancer with atelectasis
    Zhang, Hongjiao
    Fu, Chengrui
    Fan, Min
    Lu, Liyong
    Chen, Yiru
    Liu, Chengxin
    Sun, Hongfu
    Zhao, Qian
    Han, Dan
    Li, Baosheng
    Huang, Wei
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [45] Inter-observer variations of the tumor bed delineation for patients after breast conserving surgery in preoperative magnetic resonance and computed tomography scan fusion
    Jie Jiang
    Jinhu Chen
    Wanhu Li
    Yongqing Li
    Yiru Chen
    Zicheng Zhang
    Chengxin Liu
    Dan Han
    Hongfu Sun
    Baosheng Li
    Wei Huang
    BMC Cancer, 21
  • [46] Inter-observer variations of the tumor bed delineation for patients after breast conserving surgery in preoperative magnetic resonance and computed tomography scan fusion
    Jiang, Jie
    Chen, Jinhu
    Li, Wanhu
    Li, Yongqing
    Chen, Yiru
    Zhang, Zicheng
    Liu, Chengxin
    Han, Dan
    Sun, Hongfu
    Li, Baosheng
    Huang, Wei
    BMC CANCER, 2021, 21 (01)
  • [47] Inter- and Intra-observer Variability of a Cervical OPLL Classification Using Reconstructed CT Images
    Chang, Han
    Kong, Chae-Gwan
    Won, Ho-Yeon
    Kim, Ju-Hwan
    Park, Jong-Beom
    CLINICS IN ORTHOPEDIC SURGERY, 2010, 2 (01) : 8 - 12
  • [48] Impact of structured report on the quality of preoperative CT staging of pancreatic ductal adenocarcinoma: assessment of intra- and inter-reader variability
    Dimarco, Mariangela
    Cannella, Roberto
    Pellegrino, Silvia
    Iadicola, Dario
    Tutino, Roberta
    Allegra, Francesco
    Castiglione, Davide
    Salvaggio, Giuseppe
    Midiri, Massimo
    Brancatelli, Giuseppe
    Vernuccio, Federica
    ABDOMINAL RADIOLOGY, 2020, 45 (02) : 437 - 448
  • [49] Impact of structured report on the quality of preoperative CT staging of pancreatic ductal adenocarcinoma: assessment of intra- and inter-reader variability
    Mariangela Dimarco
    Roberto Cannella
    Silvia Pellegrino
    Dario Iadicola
    Roberta Tutino
    Francesco Allegra
    Davide Castiglione
    Giuseppe Salvaggio
    Massimo Midiri
    Giuseppe Brancatelli
    Federica Vernuccio
    Abdominal Radiology, 2020, 45 : 437 - 448
  • [50] Intra-observer and interobserver reliability of the ‘Pico’ computed tomography method for quantification of glenoid bone defect in anterior shoulder instability
    Nicola Magarelli
    Giuseppe Milano
    Pietro Sergio
    Domenico A. Santagada
    Carlo Fabbriciani
    Lorenzo Bonomo
    Skeletal Radiology, 2009, 38 : 1071 - 1075