Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

被引:7
|
作者
Lundqvist, Eva [1 ]
Segelsjo, Monica [1 ]
Andersson, Anna [2 ]
Magnusson, Anders [1 ]
Biglarnia, Ali-Reza [2 ]
机构
[1] Uppsala Univ, Dept Radiol Oncol & Radiat Sci, Sect Radiol, Uppsala, Sweden
[2] Univ Uppsala Hosp, Dept Surg Sci, Sect Transplantat Surg, Uppsala, Sweden
关键词
Computed tomography; volumetry; pancreas transplantation; observer variation; contrast media; KIDNEY; LIVER;
D O I
10.1258/ar.2012.120317
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose: To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods: CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results: The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion: CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume.
引用
收藏
页码:966 / 972
页数:7
相关论文
共 50 条
  • [21] Inter-Observer Variability in MR-Based Target Volume Delineation of Uveal Melanoma
    Jaarsma-Coes, Myriam G.
    Klaassen, Lisa
    Verbist, Berit M.
    Vu, T. H. Khanh
    Klaver, Yvonne L. B.
    Rodrigues, Myra F.
    Nabarro, Claire
    Luyten, Gregorius P. M.
    Rasch, Coen R. N.
    van Herk, Marcel
    Beenakker, Jan-Willem M.
    ADVANCES IN RADIATION ONCOLOGY, 2023, 8 (03)
  • [22] Inter-Observer and Intra-Observer Variability in Gross Tumor Volume Delineation of Primary Esophageal Carcinomas Based on Different Combinations of Diagnostic Multimodal Images
    Li, Fengxiang
    Li, Yankang
    Wang, Xue
    Zhang, Yingjie
    Liu, Xijun
    Liu, Shanshan
    Wang, Wei
    Wang, Jinzhi
    Guo, Yanluan
    Xu, Min
    Li, Jianbin
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [23] Intra-observer and inter-observer agreements for the measurement of dual-input whole tumor computed tomography perfusion in patients with lung cancer: Influences of the size and inner-air density of tumors
    Wang, Qingle
    Zhang, Zhiyong
    Shan, Fei
    Shi, Yuxin
    Xing, Wei
    Shi, Liangrong
    Zhang, Xingwei
    THORACIC CANCER, 2017, 8 (05) : 427 - 435
  • [24] Intra-observer and inter-observer errors in CT measurement of torsional profiles of lower limbs: a retrospective comparative study
    Panou, Artemisia
    Stanitski, Dedorah Faith
    Stanitski, Carl
    Peccati, Andrea
    Portinaro, Nicola Marcello
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2015, 10
  • [25] INTRA-OBSERVER AND DEVICE-DEPENDENT INTER-OBSERVER RELIABILITY OF CONTRAST-ENHANCED ULTRASOUND FOR MUSCLE PERFUSION QUANTIFICATION
    Kunz, Pierre
    Kiesl, Sophia
    Gro, Sascha
    Kauczor, Hans-Ulrich
    Schmidmaier, Gerhard
    Fischer, Christian
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (02): : 275 - 285
  • [26] Size measurement of lung nodules on CT: which diameter is most stable to inter-observer variability?
    Bianconi, Francesco
    Fravolini, Mario Luca
    Palumbo, Barbara
    CLINICAL IMAGING, 2023, 99 : 38 - 40
  • [27] Comparing the inter-observer reliability of the Tada formula among neurosurgeons while estimating the intracerebral haematoma volume
    Gong, Kai
    Shi, Tao
    Zhao, Lizheng
    Xu, Zhong
    Wang, Zhanxiang
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2021, 205
  • [28] Chest Magnetic Resonance Imaging Decreases Inter-observer Variability of Gross Target Volume for Lung Tumors
    Basson, Laurent
    Jarraya, Hajer
    Escande, Alexandre
    Cordoba, Abel
    Daghistani, Rayyan
    Pasquier, David
    Lacornerie, Thomas
    Lartigau, Eric
    Mirabel, Xavier
    FRONTIERS IN ONCOLOGY, 2019, 9
  • [29] Inter- and intra-observer variability of radiography and computed tomography for evaluation of Zurich cementless acetabular cup placement ex vivo
    Leasure, Jessica O.
    Peck, Jeffrey N.
    Villamil, Armando
    Fiore, Kara L.
    Tano, Cheryl A.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2016, 29 (06) : 507 - 514
  • [30] Intra- and Interobserver Variability of Aortic Aneurysm Volume Measurement With Fast CTA Postprocessing Software
    van Prehn, Joffrey
    van der Wal, Martijn B. A.
    Vincken, Koen
    Bartels, Lambertus W.
    Moll, Frans L.
    van Herwaarden, Joost A.
    JOURNAL OF ENDOVASCULAR THERAPY, 2008, 15 (05) : 504 - 510