Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

被引:7
|
作者
Lundqvist, Eva [1 ]
Segelsjo, Monica [1 ]
Andersson, Anna [2 ]
Magnusson, Anders [1 ]
Biglarnia, Ali-Reza [2 ]
机构
[1] Uppsala Univ, Dept Radiol Oncol & Radiat Sci, Sect Radiol, Uppsala, Sweden
[2] Univ Uppsala Hosp, Dept Surg Sci, Sect Transplantat Surg, Uppsala, Sweden
关键词
Computed tomography; volumetry; pancreas transplantation; observer variation; contrast media; KIDNEY; LIVER;
D O I
10.1258/ar.2012.120317
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose: To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods: CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results: The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion: CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume.
引用
收藏
页码:966 / 972
页数:7
相关论文
共 50 条
  • [1] Diaphragm Thickness Measurement in Computed Tomography: Intra- and Inter-Observer Agreement
    Ufuk, Furkan
    Cakmak, Pinar
    Sagtas, Ergin
    Herek, Duygu
    Arslan, Muhammet
    Yagci, Ahmet Baki
    ISTANBUL MEDICAL JOURNAL, 2019, 20 (02): : 101 - 106
  • [2] Computed tomography improves intra-observer reliability, but not the inter-observer reliability of the Eaton-Glickel classification
    Hansen, T. B.
    Sorensen, O. G.
    Kirkeby, L.
    Homilius, M.
    Amstrup, A. L.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2013, 38E (02) : 187 - 191
  • [3] Intra- inter-observer repeatability in liver computed tomography volumetry in patients undergoing radioembolization simulation
    Andrea Masperi
    Valerio Cubadda
    Luca Bombelli
    Roberto Labruna
    Vincenzo Bagnardi
    Cristiana Iuliana Fodor
    Eleonora Pagan
    Guido Bonomo
    Franco Orsi
    Abdominal Radiology, 2021, 46 : 3448 - 3455
  • [4] Intra- inter-observer repeatability in liver computed tomography volumetry in patients undergoing radioembolization simulation
    Masperi, Andrea
    Cubadda, Valerio
    Bombelli, Luca
    Labruna, Roberto
    Bagnardi, Vincenzo
    Fodor, Cristiana Iuliana
    Pagan, Eleonora
    Bonomo, Guido
    Orsi, Franco
    ABDOMINAL RADIOLOGY, 2021, 46 (07) : 3448 - 3455
  • [5] Intra- and inter-observer variability of functional MR urography (fMRU) assessment in children
    Dmitry Khrichenko
    David Saul
    Melkamu Adeb
    Camilo Jaimes
    Khalil N. Betts
    Stephanie M. Barron
    J. Christopher Edgar
    Sarah M. Lambert
    Pasquale Casale
    Kassa Darge
    Pediatric Radiology, 2016, 46 : 666 - 673
  • [6] Intra- and inter-observer variability of functional MR urography (fMRU) assessment in children
    Khrichenko, Dmitry
    Saul, David
    Adeb, Melkamu
    Jaimes, Camilo
    Betts, Khalil N.
    Barron, Stephanie M.
    Edgar, J. Christopher
    Lambert, Sarah M.
    Casale, Pasquale
    Darge, Kassa
    PEDIATRIC RADIOLOGY, 2016, 46 (05) : 666 - 673
  • [7] Inter-observer and inter-examination variability of manual vertebral bone attenuation measurements on computed tomography
    Pompe, Esther
    de Jong, Pim A.
    de Jong, Werner U.
    Takx, Richard A. P.
    Eikendal, Anouk L. M.
    Willemink, Martin J.
    Oudkerk, Matthijs
    Budde, Ricardo P. J.
    Lammers, Jan-Willem J.
    Hoesein, Firdaus A. A. Mohamed
    EUROPEAN RADIOLOGY, 2016, 26 (09) : 3046 - 3053
  • [8] Inter-observer and inter-examination variability of manual vertebral bone attenuation measurements on computed tomography
    Esther Pompe
    Pim A. de Jong
    Werner U. de Jong
    Richard A. P. Takx
    Anouk L. M. Eikendal
    Martin J. Willemink
    Matthijs Oudkerk
    Ricardo P. J. Budde
    Jan-Willem J. Lammers
    Firdaus A. A. Mohamed Hoesein
    European Radiology, 2016, 26 : 3046 - 3053
  • [9] INTRA- AND INTER-OBSERVER AGREEMENT OF PROXIMAL HUMERAL FRACTURES CLASSIFICATIONS IN ADULTS
    Diaz, Luis Eduardo Plumacher
    Neto, Francisco Dada
    Lofrano, Lucas
    Garcia, Joao Vitor da Cruz
    Santana, Marcos Vinicius Felix
    Dobashi, Eiffel Tsuyoshi
    ACTA ORTOPEDICA BRASILEIRA, 2022, 30 (06):
  • [10] Cardiac valve calcifications on low-dose unenhanced ungated chest computed tomography: inter-observer and inter-examination reliability, agreement and variability
    van Hamersvelt, Robbert W.
    Willemink, Martin J.
    Takx, Richard A. P.
    Eikendal, Anouk L. M.
    Budde, Ricardo P. J.
    Leiner, Tim
    Mol, Christian P.
    Isgum, Ivana
    de Jong, Pim A.
    EUROPEAN RADIOLOGY, 2014, 24 (07) : 1557 - 1564