A method for refractive index measurement of a liquid in a suspended core fiber using Brillouin dynamic grating

被引:1
|
作者
Jouybari, Soodabeh Nouri [1 ]
Latifi, Hamid [1 ]
Vahid, Shahraam Afshar [2 ]
机构
[1] Shahid Beheshti Univ, Laser & Plasma Res Inst, Tehran 1983963113, Iran
[2] Univ Adelaide, Inst Photon & Adv Sensing, Adelaide, SA 5005, Australia
关键词
microstructured fiber; refractive index; dynamic grating; Brillouin scattering; OPTICAL-FIBER; SCATTERING; SENSOR; RESOLUTION; STRAIN;
D O I
10.1080/09500340.2013.775370
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A novel method is proposed to measure the refractive index change of a liquid around a fiber using a dynamic grating generated by stimulated Brillouin scattering. Two pump waves are used to generate a dynamic grating along a polarization-maintaining fiber. The grating is then read by a probe wave. It is shown numerically that the frequency deviation of the pump and probe waves depends on the refractive index of liquid around the fiber. We consider three- and four-hole suspended core fibers, in which one or two holes are filled with liquid, and investigate the change in the birefringence and the frequency deviation of the Brillouin dynamic grating due to the variation of the refractive index of liquid. The effects of fiber parameters on the sensitivity of frequency deviation as a function of liquid refractive index are discussed. We predict that a resolution of can be obtained using this method.
引用
收藏
页码:342 / 349
页数:8
相关论文
共 50 条
  • [1] Sinusoidal-Core Long Period Fiber Grating for Refractive Index Measurement
    Ma, Yiwei
    Su, Chunbo
    Dai, Zizhao
    Tian, Tian
    Yang, Xinghua
    Geng, Tao
    Yuan, Libo
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2022, 40 (14) : 4903 - 4910
  • [2] Simultaneous measurement of refractive index and temperature based on tapered no-core fiber cascaded with a fiber Bragg grating
    Liu, Yushan
    Xie, Song
    Zheng, Yuanyuan
    Yang, Xiaozhan
    RESULTS IN OPTICS, 2022, 9
  • [3] Liquid Core Fiber Interferometer for Simultaneous Measurement of Refractive Index and Temperature
    Liu, Shuhui
    Zhang, Hailiang
    Li, Litong
    Xiong, Liangming
    Shum, Perry Ping
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2019, 31 (02) : 189 - 192
  • [4] Refractive Index Sensor Based on Fiber Bragg Grating in Hollow Suspended-Core Fiber
    Tian, Peixuan
    Zhu, Zheng
    Wang, Mingjie
    Ye, Peng
    Yang, Jing
    Shi, Jinhui
    Yang, Jun
    Guan, Chunying
    Yuan, Libo
    IEEE SENSORS JOURNAL, 2019, 19 (24) : 11961 - 11964
  • [5] Refractive index measurement based on fiber Bragg grating connected with a multimode fiber core
    Shao, Min
    Qiao, Xueguang
    Jiasurname, Zhenan
    Fusurname, Haiwei
    Liu, Yinggang
    Li, Huidong
    Zhao, Xue
    OPTICS COMMUNICATIONS, 2015, 351 : 70 - 74
  • [6] Highly Sensitive Fiber Optic Sensor for Simultaneous Refractive Index and Temperature Measurement Using Suspended Core Fiber
    Zhang, Xindi
    Zhou, Xue
    Zhang, Yanan
    Nguyen, Linh Viet
    Zhao, Yong
    Warren-Smith, Stephen C.
    Li, Xuegang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74
  • [7] OTDR based on Brillouin dynamic grating in an e-core two-mode fiber for simultaneous measurement of strain and temperature distribution
    Kim, Yong Hyun
    Song, Kwang Yong
    2017 25TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS (OFS), 2017, 10323
  • [8] Simultaneous Measurement of Temperature and Refractive Index of Liquid Using Cladding-Etched Double-Core Fiber Bragg Grating
    Kim, Kwang Taek
    Kim, In Soo
    FIBER AND INTEGRATED OPTICS, 2013, 32 (03) : 145 - 152
  • [9] Simultaneous measurement of liquid level and surrounding refractive index using tilted fiber Bragg grating
    Jiang, Qi
    Hu, Debo
    Yang, Meng
    SENSORS AND ACTUATORS A-PHYSICAL, 2011, 170 (1-2) : 62 - 65
  • [10] Hybrid Long-Period Fiber Grating with Multimode Fiber Core for Refractive Index Measurement
    Shao, Min
    Qiao, Xue-Guang
    Ren, Xue-Liang
    Yang, De-Xing
    CHINESE PHYSICS LETTERS, 2017, 34 (11)