Sensitive ionization of non-volatile analytes using protein solutions as spray liquid in desorption electrospray ionization mass spectrometry

被引:6
|
作者
Zhu, Zhiqiang [1 ]
Han, Jing [2 ]
Zhang, Yan [1 ]
Zhou, Yafei [1 ]
Xu, Ning [1 ]
Zhang, Bo [2 ]
Gu, Haiwei [1 ]
Chen, Huanwen [1 ]
机构
[1] E China Inst Technol, Jiangxi Key Lab Mass Spectrometry & Instrumentat, Nanchang 330013, Jiangxi, Peoples R China
[2] Xiamen Univ, Dept Chem, Xiamen 361005, Fujian Province, Peoples R China
基金
中国国家自然科学基金;
关键词
ASSISTED LASER DESORPTION/IONIZATION; NUCLEAR-MAGNETIC-RESONANCE; AMBIENT CONDITIONS; AQUEOUS-SOLUTION; MILK-PRODUCTS; URINE SAMPLES; EESI-MS; METABOLOMICS; CHROMATOGRAPHY; EXPLOSIVES;
D O I
10.1002/rcm.6387
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RATIONALE Desorption electrospray ionization (DESI) is the most popular ambient ionization technique for direct analysis of complex samples without sample pretreatment. However, for many applications, especially for trace analysis, it is of interest to improve the sensitivity of DESI-mass spectrometry (MS). METHODS In traditional DESI-MS, a mixture of methanol/water/acetic acid is usually used to generate the primary ions. In this article, dilute protein solutions were electrosprayed in the DESI method to create multiply charged primary ions for the desorption ionization of trace analytes on various surfaces (e.g., filter paper, glass, Al-foil) without any sample pretreatment. The analyte ions were then detected and structurally characterized using a LTQ XL mass spectrometer. RESULTS Compared with the methanol/water/acetic acid (49:49:2, v/v/v) solution, protein solutions significantly increased the signal levels of non-volatile compounds such as benzoic acid, TNT, o-toluidine, peptide and insulin in either positive or negative ion detection mode. For all the analytes tested, the limits of detection (LODs) were reduced to about half of the original values which were obtained using traditional DESI. The results showed that the signal enhancement is highly correlated with the molecular weight of the proteins and the selected solid surfaces. CONCLUSIONS The proposed DESI method is a universal strategy for rapid and sensitive detection of trace amounts of strongly bound and/or non-volatile analytes, including explosives, peptides, and proteins. The results indicate that the sensitivity of DESI can be further improved by selecting larger proteins and appropriate solid surfaces. Copyright (C) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:2770 / 2776
页数:7
相关论文
共 50 条
  • [1] Development and Applications of Liquid Sample Desorption Electrospray Ionization Mass Spectrometry
    Zheng, Qiuling
    Chen, Hao
    ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 9, 2016, 9 : 411 - 448
  • [2] Protein analysis by desorption electrospray ionization mass spectrometry and related methods
    Douglass, Kevin Aart
    Venter, Andre R.
    JOURNAL OF MASS SPECTROMETRY, 2013, 48 (05): : 553 - 560
  • [3] Synchronized Inductive Desorption Electrospray Ionization Mass Spectrometry
    Huang, Guangming
    Li, Guangtao
    Ducan, Jason
    Ouyang, Zheng
    Cooks, R. Graham
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2011, 50 (11) : 2503 - 2506
  • [4] Ion suppression effect in desorption electrospray ionization and electrospray ionization mass spectrometry
    Wang, Zheng
    Zhu, Haijing
    Huang, Guangming
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2017, 31 (23) : 1957 - 1962
  • [5] Measuring Protein-Ligand Interactions Using Liquid Sample Desorption Electrospray Ionization Mass Spectrometry
    Liu, Pengyuan
    Zhang, Jiang
    Ferguson, Carly N.
    Chen, Hao
    Loo, Joseph A.
    ANALYTICAL CHEMISTRY, 2013, 85 (24) : 11966 - 11972
  • [6] Ambient Mass Spectrometry Imaging: A Comparison of Desorption Ionization by Sonic Spray and Electrospray
    Janfelt, Christian
    Norgaard, Asger W.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (10) : 1670 - 1678
  • [7] Coupling of liquid chromatography with mass spectrometry by desorption electrospray ionization (DESI)
    Zhang, Yun
    Yuan, Zongqian
    Dewald, Howard D.
    Chen, Hao
    CHEMICAL COMMUNICATIONS, 2011, 47 (14) : 4171 - 4173
  • [8] Desorption Electrospray Ionization Mass Spectrometry of Glycosaminoglycans and Their Protein Noncovalent Complex
    Przybylski, C.
    Gonnet, F.
    Hersant, Y.
    Bonnaffe, D.
    Lortat-Jacob, H.
    Daniel, R.
    ANALYTICAL CHEMISTRY, 2010, 82 (22) : 9225 - 9233
  • [9] Trace detection of non-uniformly distributed analytes on surfaces using mass transfer and large-area desorption electrospray ionization (DESI) mass spectrometry
    Soparawalla, Santosh
    Salazar, Gary A.
    Sokol, Ewa
    Perry, Richard H.
    Cooks, R. Graham
    ANALYST, 2010, 135 (08) : 1953 - 1960
  • [10] Synchronized Desorption Electrospray Ionization Mass Spectrometry Imaging
    Comi, Troy J.
    Ryu, Seung Woo
    Perry, Richard H.
    ANALYTICAL CHEMISTRY, 2016, 88 (02) : 1169 - 1175