The CarboMedics "Top-Hat" supraannular prosthesis

被引:17
|
作者
Bernal, JM [1 ]
Martin-Duran, R
Rabasa, JM
Revuelta, JM
机构
[1] Univ Cantabria, Hosp Univ Valdecilla, Dept Cardiovasc Surg, Santander 39008, Spain
[2] Univ Cantabria, Hosp Univ Valdecilla, Dept Echocardiog, Santander 39008, Spain
来源
ANNALS OF THORACIC SURGERY | 1999年 / 67卷 / 05期
关键词
D O I
10.1016/S0003-4975(99)00170-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The CarboMedics "Top-Hat" supraannular prosthesis was designed to permit the implantation of a larger prosthesis. Methods. Between June 1993 and November 1996, 127 patients (average age, 61.8 +/- 10.2 years) received a CarboMedics "Top-Hat" supraannular aortic prosthesis. The average follow-up was 15.7 months, and all surviving patients underwent echocardiographic study. This group is compared with 656 patients in whom a standard CarboMedics prosthesis was implanted and also with 2,927 patients who received other aortic prostheses. Results. Using the standard and the supraannular sizers, there was an average increase of one size in favor of the supraannular prosthesis: 18.9 +/- 2.8 mm standard versus 20.8 +/- 2.6 mm supraannular (p < 0.005). For each prosthesis size (19 to 23 mm), the body surface area of the patients in whom a CarboMedics supraannular prosthesis was implanted was significantly smaller than that in those who received a CarboMedics standard prosthesis or any other model. Hospital mortality was 3.9%, and late mortality was 5.5%. The actuarial survival was 86.5% +/- 3.9% at 42 months. Conclusions. Using the CarboMedics supraannular prosthesis allows implantation of a larger prosthesis compared with the standard CarboMedics prosthesis or other models. This advantage is especially important in patients with a small aortic root. (Ann Thorac Surg 1999;67:1299-303) (C) 1999 by The Society of Thoracic Surgeons.
引用
收藏
页码:1299 / 1303
页数:5
相关论文
共 50 条
  • [31] Detection of microcalcification with top-hat transform and the Gibbs random fields
    Bharadwaj, Akshay S.
    Celenk, Mehmet
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 6382 - 6385
  • [32] The Top-Hat Flap: A New Technique for Segmental Nailbed Reconstruction
    Ecker, Jeff
    Andrijich, Courtney
    Smith, Nicholas W. S.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2024, 154 (03) : 514e - 516e
  • [33] JOINT AND ASSEMBLE OF HUGE COMPOSITE TOP-HAT STIFFENED HULLS
    Zhang, Jifeng
    Zhou, Limin
    20TH INTERNATIONAL CONFERENCE ON COMPOSITE MATERIALS, 2015,
  • [34] tip of the hat: Hollow top-hat DOE shaping for improving BER in laser communications
    Li, M.
    Chen, Y.
    Yu, J.
    Chen, M.
    Song, Y.
    Electronics Letters, 2020, 56 (16):
  • [35] Flexural behaviour of top-hat stiffened GFRP plate panels
    Eksik, O
    Shenoi, RA
    Moy, SSJ
    Jeong, HK
    PROCEEDINGS OF THE ACMC/SAMPE CONFERENCE ON MARINE COMPOSITES, 2003, : 163 - 173
  • [36] Top-Hat Monopole Antenna for Conical-Beam Radiation
    Shen, Zhongxiang
    Wang, Jianpeng
    IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2011, 10 : 396 - 398
  • [37] Spherical top-hat collapse of a viscous unified dark fluid
    Li, Wei
    Xu, Lixin
    EUROPEAN PHYSICAL JOURNAL C, 2014, 74 (05): : 1 - 7
  • [38] ELECTRIC TOP-HAT FURNACE REDUCES STRESS RELIEVING COSTS
    不详
    MACHINERY AND PRODUCTION ENGINEERING, 1971, 119 (3083): : 885 - &
  • [39] Z-SCAN TECHNIQUE USING TOP-HAT BEAMS
    ZHAO, W
    PALFFYMUHORAY, P
    APPLIED PHYSICS LETTERS, 1993, 63 (12) : 1613 - 1615
  • [40] Spherical top-hat collapse of a viscous unified dark fluid
    Wei Li
    Lixin Xu
    The European Physical Journal C, 2014, 74