The CarboMedics "Top-Hat" supraannular prosthesis

被引:17
|
作者
Bernal, JM [1 ]
Martin-Duran, R
Rabasa, JM
Revuelta, JM
机构
[1] Univ Cantabria, Hosp Univ Valdecilla, Dept Cardiovasc Surg, Santander 39008, Spain
[2] Univ Cantabria, Hosp Univ Valdecilla, Dept Echocardiog, Santander 39008, Spain
来源
ANNALS OF THORACIC SURGERY | 1999年 / 67卷 / 05期
关键词
D O I
10.1016/S0003-4975(99)00170-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The CarboMedics "Top-Hat" supraannular prosthesis was designed to permit the implantation of a larger prosthesis. Methods. Between June 1993 and November 1996, 127 patients (average age, 61.8 +/- 10.2 years) received a CarboMedics "Top-Hat" supraannular aortic prosthesis. The average follow-up was 15.7 months, and all surviving patients underwent echocardiographic study. This group is compared with 656 patients in whom a standard CarboMedics prosthesis was implanted and also with 2,927 patients who received other aortic prostheses. Results. Using the standard and the supraannular sizers, there was an average increase of one size in favor of the supraannular prosthesis: 18.9 +/- 2.8 mm standard versus 20.8 +/- 2.6 mm supraannular (p < 0.005). For each prosthesis size (19 to 23 mm), the body surface area of the patients in whom a CarboMedics supraannular prosthesis was implanted was significantly smaller than that in those who received a CarboMedics standard prosthesis or any other model. Hospital mortality was 3.9%, and late mortality was 5.5%. The actuarial survival was 86.5% +/- 3.9% at 42 months. Conclusions. Using the CarboMedics supraannular prosthesis allows implantation of a larger prosthesis compared with the standard CarboMedics prosthesis or other models. This advantage is especially important in patients with a small aortic root. (Ann Thorac Surg 1999;67:1299-303) (C) 1999 by The Society of Thoracic Surgeons.
引用
收藏
页码:1299 / 1303
页数:5
相关论文
共 50 条
  • [1] THE CARBOMEDICS(R) TOP HAT SUPRAANNULAR PROSTHESIS IN THE SMALL AORTIC ROOT
    ROEDLER, S
    MORITZ, A
    WUTTE, M
    HODA, R
    WOLNER, E
    JOURNAL OF CARDIAC SURGERY, 1995, 10 (03) : 198 - 204
  • [2] The CarboMedics supraannular top hat valve improves prosthesis size in the aortic root
    Lundblad, R
    Hagen, OM
    Smith, G
    Kvernebo, K
    JOURNAL OF HEART VALVE DISEASE, 2001, 10 (02): : 196 - 201
  • [3] The CarboMedics 'Top-Hat' aortic valve prosthesis: Short-term results
    Binuani, P
    Baufreton, C
    Subayi, JB
    de Brux, JL
    JOURNAL OF HEART VALVE DISEASE, 2000, 9 (05): : 693 - 696
  • [4] The carbomedics top hat supraannular aortic valve: A multicenter study
    Gillinov, AM
    Blackstone, EH
    Alster, JM
    Craver, JM
    Baumgartner, WA
    Brewster, SA
    Kleinman, LH
    Smedira, NG
    ANNALS OF THORACIC SURGERY, 2003, 75 (04): : 1175 - 1180
  • [5] CONSTRUCT A TOP-HAT
    HOLKEBOER, K
    THEATRE CRAFTS, 1984, 18 (07): : 112 - &
  • [6] Performance at 10 years of the CarboMedics 'Top-Hat' valve.: Postclamping time is a predictor of mortality
    Bernal, JM
    Lorca, J
    Prieto-Salceda, D
    Pulitani, I
    Pontón, A
    García, I
    Revuelta, JM
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2006, 29 (02) : 144 - 149
  • [7] TOP-HAT SET
    STEWART, JB
    BRITISH MEDICAL JOURNAL, 1967, 2 (5548): : 379 - &
  • [8] Analysis of top-hat selection transformation and some modified top-hat transformations
    Bai, Xiangzhi
    Zhou, Fugen
    Liu, Zhaoying
    Xue, Bindang
    Jin, Ting
    OPTIK, 2012, 123 (10): : 892 - 895
  • [9] Improved morphological top-hat
    Jackway, PT
    ELECTRONICS LETTERS, 2000, 36 (14) : 1194 - 1195
  • [10] Doppler-echocardiographic assessment of the CarboMedics supra-annular 'Top-Hat' prosthetic heart valve in the aortic position
    deBrux, JL
    Subayi, JB
    Binuani, P
    Laporte, J
    JOURNAL OF HEART VALVE DISEASE, 1996, 5 : S336 - S338