Electrochemical Detection of Glucose in Beverage Samples Using Poly(3,4-ethylenedioxythiophene)-Modified Electrodes with Immobilized Glucose Oxidase

被引:25
|
作者
Krzyczmonik, Pawe [1 ]
Socha, Ewelina [1 ]
Skrzypek, Slawomira [1 ]
机构
[1] Univ Lodz, Dept Inorgan & Analyt Chem, Ul Tamka 12, PL-91403 Lodz, Poland
关键词
Amperometric sensor; Biosensor; Glucose; Glucose oxidase; PEDOT; FLOW-INJECTION ANALYSIS; ENZYME ELECTRODE; AMPEROMETRIC DETERMINATION; CARBON NANOTUBES; BIOSENSOR; ENTRAPMENT; STABILITY;
D O I
10.1007/s12678-017-0442-2
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We developed two glucose biosensors based on poly(3,4-ethylenedioxythiophene) (PEDOT) and polyacrylic acid (PAA) doped with poly(4-lithium styrenesulfonic acid) (PSSLi) or PEDOT and anthranilic acid (AA) doped with poly(4-styrenesulfonic acid) (PSSH). The first one was already mentioned in literature in similar configurations; however, the second one has not been described before. The glucose oxidase was immobilized by means of covalent bonding, which has been proved by spectrophotometric assay with o-dianisidine. Amperometric measurements were carried out for the determination of glucose in phosphate buffer. The prepared electrodes functioned as first-generation glucose biosensors at applied potential E = + 0.6 V during t = 30 s. The elaborated procedure was validated, and all of the statistical parameters met the requirements for biosensors. The presented method was successfully applied for determination of glucose concentration in food samples, such as grape juice and honey. The activity of the presented biosensors was also studied in the presence of ascorbic acid and uric acid, acting as interfering agents.
引用
收藏
页码:380 / 387
页数:8
相关论文
共 50 条
  • [41] Mercury(II) Extraction Using a Poly(3,4-Ethylenedioxythiophene) Modified Electrode
    Arteaga, G. C.
    del Valle, M. A.
    Antilen, M.
    Faundez, M.
    Gacitua, M. A.
    Diaz, F. R.
    Bernede, J. C.
    Cattin, L.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (11): : 5209 - 5218
  • [42] Spectroelectrochemical characteristics of poly(3,4-ethylenedioxythiophene)/iron hexacyanoferrate film-modified electrodes
    Andrzej P. Nowak
    Monika Wilamowska
    Anna Lisowska-Oleksiak
    Journal of Solid State Electrochemistry, 2010, 14 : 263 - 270
  • [43] Graphene oxide doped poly(3,4-ethylenedioxythiophene) modified with copper nanoparticles for high performance nonenzymatic sensing of glucose
    Hui, Ni
    Wang, Wenting
    Xu, Guiyun
    Luo, Xiliang
    JOURNAL OF MATERIALS CHEMISTRY B, 2015, 3 (04) : 556 - 561
  • [44] Spectroelectrochemical characteristics of poly(3,4-ethylenedioxythiophene)/iron hexacyanoferrate film-modified electrodes
    Nowak, Andrzej P.
    Wilamowska, Monika
    Lisowska-Oleksiak, Anna
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2010, 14 (02) : 263 - 270
  • [45] A glucose biosensor based on modified-enzyme incorporated within electropolymerised poly(3,4-ethylenedioxythiophene) (PEDT) films
    Piro, B
    Dang, LA
    Pham, MC
    Fabiano, S
    Tran-Minh, C
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 512 (1-2) : 101 - 109
  • [46] Electrochemical behaviors of roxithromycin at poly(3,4-ethylenedioxythiophene) modified gold electrode and its electrochemical determination
    Zhang, Long
    Duan, Xuemin
    Wen, Yangping
    Xu, Jingkun
    Yao, Yuanyuan
    Lu, Yao
    Lu, Limin
    Zhang, Cu
    ELECTROCHIMICA ACTA, 2012, 72 : 179 - 185
  • [47] Highly sensitive poly(3,4-ethylenedioxythiophene) modified electrodes by electropolymerisation in deep eutectic solvents
    Prathish, Krishna P.
    Carvalho, Ricardo C.
    Brett, Christopher M. A.
    ELECTROCHEMISTRY COMMUNICATIONS, 2014, 44 : 8 - 11
  • [48] Amperometric sensors based on poly (3,4-ethylenedioxythiophene)-modified electrodes: Discrimination of white wines
    Pigani, L.
    Foca, G.
    Ionescu, K.
    Martina, V.
    Ulrici, A.
    Terzi, F.
    Vignali, M.
    Zanardi, C.
    Seeber, R.
    ANALYTICA CHIMICA ACTA, 2008, 614 (02) : 213 - 222
  • [49] Electrochemistry of sulfur dioxide, polyphenols and ascorbic acid at poly(3,4-ethylenedioxythiophene) modified electrodes
    Tuerke, A.
    Fischer, W. - J.
    Beaumont, N.
    Kilmartin, P. A.
    ELECTROCHIMICA ACTA, 2012, 60 : 184 - 192
  • [50] Glucose sensing electrodes based on a poly(3,4-ethylenedioxythiophene)/Prussian blue bilayer and multi-walled carbon nanotubes
    Chiu, Jing-Yang
    Yu, Chung-Mu
    Yen, Miao-Ju
    Chen, Lin-Chi
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (07): : 2015 - 2020