Effectiveness of Stack Ventilation in a Two-Storey House in Hot and Humid Climate

被引:0
作者
Chindavanig, Thanit [1 ]
机构
[1] Chulalongkorn Univ, Fac Architecture, Dept Architecture, Bangkok 10330, Thailand
来源
3RD WORLD MULTIDISCIPLINARY CIVIL ENGINEERING, ARCHITECTURE, URBAN PLANNING SYMPOSIUM (WMCAUS 2018) | 2019年 / 471卷
关键词
D O I
10.1088/1757-899X/471/6/062008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The objectives of this research were to design stack ventilation and to study its effectiveness in a two-storey house in hot and humid climate of Bangkok, Thailand Envelope openings at the rooftop and the entry door of the house were added to create height difference between inlet and outlet openings. Heat in the attic was utilized to make temperature difference in order to generate buoyancy for stack ventilation. The method of the study was experimentation in two existing houses, which had the same physical and had the most similar environment. The first house without stack ventilation was a base case. The second one was designed to integrate stack ventilation. Scientific instruments were installed in both houses at various positions. Air temperature, relative humidity and wind speed data were collected minutely for a few consecutive days for the evaluation of the experiment. It was founded that the house with stack ventilation had inside air temperature and relative humidity lower than those of the base case. The inside air temperature of the house with stack ventilation could be 0.7 Celsius lower than that of the base case. The relative humidity of the house with stack ventilation could have relative humidity of 12 % lower than that of the base case. Furthermore, the stack ventilation could make 1.06 air changes per hour with only 0.10% effective opening of building area having stack ventilation.
引用
收藏
页数:10
相关论文
共 50 条
[41]   A literature review on the improvement strategies of passive design for the roofing system of the modern house in a hot and humid climate region [J].
Roslan, Qairuniza ;
Ibrahim, Siti Halipah ;
Affandi, Rohaida ;
Nawi, Mohd Nasrun Mohd ;
Baharun, Azhaili .
FRONTIERS OF ARCHITECTURAL RESEARCH, 2016, 5 (01) :126-133
[42]   Passive environmental design of an eco-house in the hot-humid climate of the Middle East: A qualitative approach [J].
Khoukhi, Maatouk ;
Shaaban, Awni K. ;
Al Khatib, Omar .
COGENT ENGINEERING, 2020, 7 (01)
[43]   A literature review on the improvement strategies of passive design for the roofing system of the modern house in a hot and humid climate region [J].
Qairuniza Roslan ;
Siti Halipah Ibrahim ;
Rohaida Affandi ;
Mohd Nasrun Mohd Nawi ;
Azhaili Baharun .
Frontiers of Architectural Research, 2016, 5 (01) :126-133
[44]   Effectiveness of an ultraviolet germicidal irradiation system in enhancing cooling coil energy performance in a hot and humid climate [J].
Wang, Yi ;
Sekhar, Chandra ;
Bahnfleth, William P. ;
Cheong, Kok Wai ;
Firrantello, Joseph .
ENERGY AND BUILDINGS, 2016, 130 :321-329
[45]   Influence of cross-ventilation cooling potential on thermal comfort in high-rise buildings in a hot and humid climate [J].
Stasi, Roberto ;
Ruggiero, Francesco ;
Berardi, Umberto .
BUILDING AND ENVIRONMENT, 2024, 248
[46]   Effectiveness of passive design strategies in responding to future climate change for residential buildings in hot and humid Hong Kong [J].
Liu, Sheng ;
Kwok, Yu Ting ;
Lau, Kevin Ka-Lun ;
Ouyang, Wanlu ;
Ng, Edward .
ENERGY AND BUILDINGS, 2020, 228
[47]   Design configurations analysis of wind-induced natural ventilation tower in hot humid climate using computational fluid dynamics [J].
Lim, Chin Haw ;
Saadatian, Omidreza ;
Sopian, Kamaruzzaman ;
Sulaiman, M. Yusof ;
Mat, Sohif ;
Salleh, Elias ;
Ng, K. C. .
INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2015, 10 (04) :332-346
[48]   Thermal comfort and IAQ assessment of under-floor air distribution system integrated with personalized ventilation in hot and humid climate [J].
Li, Ruixin ;
Sekhar, S. C. ;
Melikov, A. K. .
BUILDING AND ENVIRONMENT, 2010, 45 (09) :1906-1913
[49]   EFFECT OF TWO COOLING FREQUENCIES ON RESPIRATION RATE IN LACTATING DAIRY COWS UNDER HOT AND HUMID CLIMATE CONDITIONS [J].
Pinto, Severino ;
Hoffmann, Gundula ;
Ammon, Christian ;
Heuwieser, Wolfgang ;
Levit, Harel ;
Halachmi, Ilan ;
Amon, Thomas .
ANNALS OF ANIMAL SCIENCE, 2019, 19 (03) :821-834
[50]   Study of an integrated personalized ventilation and local fan-induced active chilled beam air conditioning system in hot and humid climate [J].
Chandra Sekhar ;
Long Zheng .
Building Simulation, 2018, 11 :787-801