Discrimination and quantification of two isomeric antineoplastic drugs by rapid and non-invasive analytical control using a handheld Raman spectrometer

被引:23
作者
Le, L. M. M. [1 ,2 ]
Tfayli, A. [1 ]
Zhou, J. [1 ]
Prognon, P. [1 ,2 ]
Baillet-Guffroy, A. [1 ]
Caudron, E. [1 ,2 ]
机构
[1] Univ Paris Saclay, U Psud, Lip Sys 2, EA7357,UFR Pharm, Chatenay Malabry, France
[2] Hop Europeen Georges Pompidou, AP HP, Dept Pharm, 20 Rue Leblanc, F-75015 Paris, France
关键词
Anthracycline; Raman spectroscopy; Quantification; Discrimination; Handheld device; QUANTITATIVE ANALYTICAL PROCEDURES; NEAR-INFRARED SPECTROSCOPY; QUALITY-CONTROL; CHEMOTHERAPIES PREPARATIONS; ANTICANCER DRUGS; SFSTP PROPOSAL; HARMONIZATION; STRATEGIES; VALIDATION; LIQUID;
D O I
10.1016/j.talanta.2016.07.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Raman spectroscopy is a rapid, non-destructive and non-invasive method that is a promising tool for real-time analytical control of drug concentrations. This study evaluated a handheld Raman device to discriminate and quantify two isomeric drugs used to treat cancer. Doxorubicin (DOXO) and epirubicin (EPIR) samples were analyzed at therapeutic concentrations from 0.1 to 2 mg/mL (n=90) and 0.08-2 mg/mL (n=90) by non-invasive measurements using a portable Raman spectrometer. The discrimination of these two molecules was demonstrated for all concentrations (n=180) by qualitative analysis using partial least square discriminant analysis (PLS-DA) with 100% classification accuracy, sensitivity and specificity and 0% error rate. For each molecule, quantitative analyses were performed using PLS regression. The validity of the model was evaluated using root mean square error of cross validation (RMSECV) and prediction (RMSEP) that furnished 0.05 and 0.02 mg/mL for DOXO and 0.17 and 0.16 mg/mL for EPIR after pretreatment optimization. Based on the accuracy profile, the linearity range was from 1.256 to 2.000 mg/mL for DOXO (R-2=0.9988) and from 0.553 to 2.000 mg/Ml for EPIR (R-2=0.9240) and repeatability (CV% max of 1.8% for DOXO and 3.2% for EPIR) and intermediate precision (CV% max of 2.8% for DOXO and 4.5% for EPIR) were both acceptable. Despite the narrow validated concentration range for quantitative analysis, this study shows the potential of a handheld Raman spectrometer coupled to chemometric approaches for real-time quantification of cytotoxic drugs, as well for discriminating between two drugs with similar UV absorption profiles. Finally, the use of a handheld spectrometer with the possibility of a direct measurement of substances in containers is a potentially valuable tool for combining patient safety with security of healthcare workers. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:320 / 324
页数:5
相关论文
共 22 条
  • [1] Agence Francaise de Securite Sanitaire des Produits de Sante/French Agency for the Safety of Health Products (AFSSAPS), 2009, MED ERR SECT DESCR R
  • [2] Routine application of Raman spectroscopy in the quality control of hospital compounded ganciclovir
    Amin, Alexandre
    Bourget, Philippe
    Vidal, Fabrice
    Ader, Flavie
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2014, 474 (1-2) : 193 - 201
  • [3] Bazin C., 2014, Annales Pharmaceutiques Francaises, V72, P33, DOI 10.1016/j.pharma.2013.09.006
  • [4] Comparative analysis of methods for real-time analytical control of chemotherapies preparations
    Bazin, Christophe
    Cassard, Bruno
    Caudron, Eric
    Prognon, Patrice
    Havard, Laurent
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2015, 494 (01) : 329 - 336
  • [5] The Raman Spectroscopy (RS): A new tool for the analytical quality control of injectable in health settings. Comparison of RS technique versus HPLC and UV/Vis-FTIR, applied to anthracyclines as anticancer drugs
    Bourget, P.
    Amin, A.
    Moriceau, A.
    Cassard, B.
    Vidal, F.
    Clement, R.
    [J]. PATHOLOGIE BIOLOGIE, 2012, 60 (06): : 369 - 379
  • [6] Comparison of Raman spectroscopy vs. high performance liquid chromatography for quality control of complex therapeutic objects: Model of elastomeric portable pumps filled with a fluorouracil solution
    Bourget, Philippe
    Amin, Alexandre
    Vidal, Fabrice
    Merlette, Christophe
    Lagarce, Frederic
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 91 : 176 - 184
  • [7] Non-invasive determination of ethanol, propylene glycol and water in a multi-component pharmaceutical oral liquid by direct measurement through amber plastic bottles using Fourier transform near-infrared spectroscopy
    Broad, NW
    Jee, RD
    Moffat, AC
    Eaves, MJ
    Mann, WC
    Dziki, W
    [J]. ANALYST, 2000, 125 (11) : 2054 - 2058
  • [8] Recent advances in the application of transmission Raman spectroscopy to pharmaceutical analysis
    Buckley, Kevin
    Matousek, Pavel
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 55 (04) : 645 - 652
  • [9] Raman spectroscopy for the process analysis of the manufacturing of a suspension metered dose inhaler
    Butz, James
    de la Cruz, Luis
    DiTonno, Jason
    DeBoyace, Kevin
    Ewing, Gary
    Donovan, Brent
    Medendorp, Joseph
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (05) : 1013 - 1019
  • [10] Near infrared and Raman spectroscopy for the in-process monitoring of pharmaceutical production processes
    De Beer, T.
    Burggraeve, A.
    Fonteyne, M.
    Saerens, L.
    Remon, J. P.
    Vervaet, C.
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2011, 417 (1-2) : 32 - 47