Radial Dilation of Nephrostomy Balloons: A Comparative Analysis

被引:9
作者
Hendlin, Karl [1 ]
Monga, Manoj [1 ]
机构
[1] Univ Minnesota, Dept Urol Surg, VAHCS Minneapolis, Minneapolis, MN 55455 USA
来源
INTERNATIONAL BRAZ J UROL | 2008年 / 34卷 / 05期
关键词
balloon dilation; percutaneous nephrolithotomy; renal calculi;
D O I
10.1590/S1677-55382008000500002
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The dynamics of percutaneous balloon expansion may differ with increasing extrinsic compressive forces and increasing inflation pressures. This study compares the ability of percutaneous balloons to expand under different radial constrictive forces Materials and Methods. Three 30F nephrostomy balloons were tested: Bard X-Force, Boston Scientific Microvasive Amplatz Tractmaster (TM), and Cook Ultraxx (TM) With a super stiff guidewire in place, the balloon tip was secured by elevated vice grips on either side of the balloon. A string was wrapped around the balloon center once, and incremental increases in load were added (2g, 42g, 82g, and 122g) to represent increasing extrinsic compression. The balloon was inflated with a contrast agent and circumference changes were measured at increments of 4 ATM, 10 ATM, and burst pressure Balloons were tested in triplicate for each load. Results. All balloons were unable to reach 90% of their expected diameter with larger constrictive loads (122g) at low (4 ATM) and nominal (10 ATM) inflation pressures Only the Bard and Cook balloons reached at least 90% of the expected diameter with a coefficient of variance (CV) less than 10% at burst pressure under the larger constrictive load (122g), 94.3% +/- 6.7%, CV 7.1% and 96.3% +/- 2 9%, CV 3 0% respectively All balloons performed well under low constriction forces and reached at least 80% of the expected diameter by 10 ATM under all constrictive loads. Conclusions The Bard X-Force and Cook Ultraxx percutaneous nephrostomy balloons achieved the most reliable radial dilation against large constrictive forces simulating fascial or retroperitoneal scar tissue.
引用
收藏
页码:546 / 552
页数:7
相关论文
共 15 条
  • [1] Al-Kandari AM, 2007, UROLOGY, V69, P586, DOI 10.1016/j.urology.2007.01.025
  • [2] [Anonymous], CAMPBELLS UROLOGY
  • [3] PERCUTANEOUS NEPHROSTOMY - ASSESSMENT OF RENAL DAMAGE ASSOCIATED WITH SEMIRIGID (24F)-DILATION AND BALLOON (36F)-DILATION
    CLAYMAN, RV
    ELBERS, J
    MILLER, RP
    WILLIAMSON, J
    MCKEEL, D
    WASSYNGER, W
    [J]. JOURNAL OF UROLOGY, 1987, 138 (01) : 203 - 206
  • [4] Influence of technique of percutaneous tract creation on incidence of renal hemorrhage
    Davidoff, R
    Bellman, GC
    [J]. JOURNAL OF UROLOGY, 1997, 157 (04) : 1229 - 1231
  • [5] Radially expanding single-step nephrostomy tract dilator
    Goharderakhshan, RZ
    Schwartz, BF
    Rudnick, DM
    Irby, PB
    Stoller, ML
    [J]. UROLOGY, 2001, 58 (05) : 693 - 696
  • [6] Radial dilation of ureteral balloons:: Comparative in vitro analysis
    Hendlin, K
    Lund, B
    Dockendorf, K
    Ramani, A
    Monga, M
    [J]. JOURNAL OF ENDOUROLOGY, 2005, 19 (05) : 575 - 578
  • [7] Failed percutaneous balloon dilation for renal access: Incidence and risk factors
    Joel, AB
    Rubenstein, JN
    Hsieh, MH
    Chi, T
    Meng, MV
    Stoller, ML
    [J]. UROLOGY, 2005, 66 (01) : 29 - 32
  • [8] First prize - Factors affecting blood loss during percutaneous nephrolithotomy: Prospective study
    Kukreja, R
    Desai, M
    Patel, S
    Bapat, S
    Desai, M
    [J]. JOURNAL OF ENDOUROLOGY, 2004, 18 (08) : 715 - 722
  • [9] Urologist-acquired renal access for percutaneous renal surgery
    Lashley, DB
    Fuchs, EF
    [J]. UROLOGY, 1998, 51 (06) : 927 - 931
  • [10] Miller NL, 2007, J UROLOGY, V178, P15, DOI 10.1016/j.juro.2007.03.014