Quantification with a dedicated breast PET/CT scanner

被引:11
|
作者
Bowen, Spencer L. [1 ]
Ferrero, Andrea [2 ]
Badawi, Ramsey D. [3 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Athinoula A Martinos Ctr Biomed Imaging, Charlestown, MA 02129 USA
[2] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[3] Univ Calif Davis, Med Ctr, Dept Radiol, Sacramento, CA 95817 USA
基金
美国国家卫生研究院;
关键词
PET/CT; positron emission mammography; dedicated; breast cancer; POSITRON EMISSION MAMMOGRAPHY; COMPONENT-BASED NORMALIZATION; 3D PET; ATTENUATION CORRECTION; IMAGING-SYSTEM; COMPUTED-TOMOGRAPHY; DETECTOR EFFICIENCY; SCATTER CORRECTION; COMPTON SCATTER; CANCER;
D O I
10.1118/1.3703593
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Dedicated breast PET/CT is expected to have utility in local staging, surgical planning, monitoring of therapy response, and detection of residual disease for breast cancer. Quantitative metrics will be integral to several such applications. The authors present a validation of fully 3D data correction schemes for a custom built dedicated breast PET/CT (DbPET/CT) scanner via F-18-FDG phantom scans. Methods: A component-based normalization was implemented, live-time was estimated with a multicomponent model, and a variance reduced randoms estimate was computed from delayed coincidences. Attenuation factors were calculated by using a CT based segmentation scheme while scatter was computed using a Monte Carlo (MC) simulation method. As no performance standard currently exists for breast PET systems, custom performance tests were created based on prior patient imaging results. Count-rate linearity for live-time and randoms corrections was measured with a decay experiment for a solid polyethylene cylinder phantom with an offset line source. A MC simulation was used to validate attenuation correction, a multicompartment phantom with asymmetric activity distribution provided an assessment of scatter correction, and image uniformity after geometric and detector normalization was measured from a high count scan of a uniform cylinder phantom. Raw data were reconstructed with filtered back projection (FBP) after Fourier rebinning. To quantify performance absolute activity concentrations, contrast recovery coefficients and image uniformity were calculated through region of interest analysis. Results: The most significant source of error was attributed to mispositioning of events due to pileup, presenting in count-related axial and transaxial nonuniformities that were not corrected for with the normalization method used here. Within the range of singles counts observed during clinical trials residual error after applying all corrections was comparable to that of a commercial whole body PET/CT system. Conclusions: The results suggest that DbPET/CT is capable of producing quantitative images under the operating conditions expected during patient imaging. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.3703593]
引用
收藏
页码:2694 / 2707
页数:14
相关论文
共 50 条
  • [1] PET characteristics of a dedicated breast PET/CT scanner prototype
    Wu, Yibao
    Bowen, Spencer L.
    Yang, Kai
    Packard, Nathan
    Fu, Lin
    Burkett, George, Jr.
    Qi, Jinyi
    Boone, John M.
    Cherry, Simon R.
    Badawi, Ramsey D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (13): : 4273 - 4287
  • [2] Modular detector for a dedicated PET/CT breast scanner
    Raylman, Raymond
    Majewski, Stan
    Stolin, Alexander
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [3] Characteristics of the PET Component of a Dedicated Breast PET/CT Scanner Prototype
    Wu, Yibao
    Yang, Kai
    Packard, Nathan
    Fu, Lin
    Stickel, Jennifer
    Tran, Vi-Hoa
    Qi, Jinyi
    Boone, John M.
    Cherry, Simon R.
    Badawi, Ramsey D.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2335 - 2339
  • [4] Comparison of Optimized WB PET/CT Breast Imaging Protocol to a Dedicated Breast PET scanner
    Ivanovic, M.
    Yoder, B.
    Khandani, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S414 - S414
  • [5] A dedicated PET scanner for breast cancer
    Freifelder, R
    Karp, JS
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1358 - 1362
  • [6] Initial Characterization of a Dedicated Breast PET/CT Scanner During Human Imaging
    Bowen, Spencer L.
    Wu, Yibao
    Chaudhari, Abhijit J.
    Fu, Lin
    Packard, Nathan J.
    Burkett, George W.
    Yang, Kai
    Lindfors, Karen K.
    Shelton, David K.
    Hagge, Rosalie
    Borowsky, Alexander D.
    Martinez, Steve R.
    Qi, Jinyi
    Boone, John M.
    Cherry, Simon R.
    Badawi, Ramsey D.
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (09) : 1401 - 1408
  • [7] A dedicated breast-PET/CT scanner: Evaluation of basic performance characteristics
    Raylman, Raymond R.
    Van Kampen, Will
    Stolin, Alexander V.
    Gong, Wenbo
    Jaliparthi, Gangadhar
    Martone, Peter F.
    Smith, Mark F.
    Sarment, David
    Clinthorne, Neal H.
    Perna, Mark
    MEDICAL PHYSICS, 2018, 45 (04) : 1603 - 1613
  • [8] Progress in the development of a dedicated breast CT scanner
    Kwan, A
    Shah, N
    Burkett, G
    Seibert, JA
    Lindfors, KK
    Nelson, TR
    Boone, JM
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 304 - 310
  • [9] A dedicated breast-PET/CT scanner: Numerical observer study of lesion detection
    Raylman, Raymond R.
    Stolin, Alexander
    Hays, Savannah
    Johnson, Evan
    Lankas, Sarah
    Mekonnen, Mahder
    Roemer, Kathryn
    MEDICAL PHYSICS, 2022, 49 (12) : 7489 - 7496
  • [10] Performance of PET Imaging in a Dedicated Breast PET-DBT scanner
    Krishnamoorthy, Srilalan
    Morales, Emmanuel
    Ashmanskas, William
    Karp, Joel
    Surti, Suleman
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62