Effect of cone installation in a pleated filter cartridge during pulse-jet cleaning

被引:67
作者
Li, Jianlong [1 ,2 ]
Li, Shihang [1 ,2 ]
Zhou, Fubao [1 ,2 ,3 ]
机构
[1] China Univ Min & Technol, Key Lab Gas & Fire Control Coal Mines, Minist Educ, Xuzhou 221116, Peoples R China
[2] China Univ Min & Technol, Sch Safety Engn, Xuzhou 221116, Peoples R China
[3] China Univ Min & Technol, State Key Lab Coal Resources & Mine Safety, Xuzhou 221116, Peoples R China
关键词
Pleated filter cartridge; Pulse-jet; Transient pressure; Cone; Uniformity; Cleaning; PRESSURE-DROP; FLAT; FLOW;
D O I
10.1016/j.powtec.2015.06.071
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This study investigated the pressure inside a pleated filter cartridge and the dust cleaning efficiency when normal and cylindrical cones were installed in a cartridge during a pulse-jet process. An experimental pulse-jet pleated filter dust collector was designed. The static pressures at three points along the length of the pleated filter cartridge were measured and compared before and after the cartridge was installed with cones. Various parameters, including tank pressure, nozzle diameter and jet distance, were investigated. The pressure drop of the filter cartridge and the dust emission concentration were also studied. This study has demonstrated that the increase in tank pressure improves pulse-jet intensity regardless of the presence of cones in the cartridge. Pulse-jet intensity is also enhanced when the cartridge is installed with either type of cone. Pulse-jet uniformity is reduced for normal cone but increased for cylindrical cone. The effect of cones on pulse-jet pressure is verified by operating performance during dust clogging and cleaning in clean-on-demand mode. The residual pressure drop is decreased, and the peak concentration of dust emission is increased when the normal or cylindrical cone is installed in the cartridge. A cylindrical cone extends the cleaning interval and reduces the dust emission, while the normal cone accomplishes the opposite. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:245 / 252
页数:8
相关论文
共 20 条
[1]   Optimization of nozzle design for pulse cleaning of ceramic filter [J].
Chi Huachang ;
Yu Liang ;
Choi Joo-Hong ;
Ji Zhongli .
CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2008, 16 (02) :306-313
[2]   Modeling instantaneous pressure drop of pleated thin filter media during dust loading [J].
Fotovati, S. ;
Hosseini, S. A. ;
Tafreshi, H. Vahedi ;
Pourdeyhimi, B. .
CHEMICAL ENGINEERING SCIENCE, 2011, 66 (18) :4036-4046
[3]  
Hao W., 2011, BUILD ENERGY ENV, V30, P64
[4]  
Ji ZL, 2003, CHINESE J CHEM ENG, V11, P626
[5]   Influence of Humidity on Clogging of Flat and Pleated HEPA Filters [J].
Joubert, A. ;
Laborde, J. C. ;
Bouilloux, L. ;
Calle-Chazelet, S. ;
Thomas, D. .
AEROSOL SCIENCE AND TECHNOLOGY, 2010, 44 (12) :1065-1076
[6]  
Ju M., 2013, HEAT VENT AIR COND, V43, P123
[7]  
[巨敏 Ju Min], 2013, [环境工程学报, Chinese Journal of Environmental Engineering], V7, P1091
[8]   Time dependency of the pressure drop in a flat type pulse jet fabric filter [J].
Kanaoka, C ;
Yao, YP .
KAGAKU KOGAKU RONBUNSHU, 2003, 29 (02) :267-271
[9]   Numerical study of pleated fabric cartridges during pulse-jet cleaning [J].
Lo, Li-Ming ;
Hu, Shih-Cheng ;
Chen, Da-Ren ;
Pui, David Y. H. .
POWDER TECHNOLOGY, 2010, 198 (01) :75-81
[10]   Experimental study of pleated fabric cartridges in a pulse-jet cleaned dust collector [J].
Lo, Li-Ming ;
Chen, Da-Ren ;
Pui, David Y. H. .
POWDER TECHNOLOGY, 2010, 197 (03) :141-149