Results of an integration study of a diagnostics port plug in ITER

被引:4
作者
Salasca, Sophie [1 ]
Cantone, Bruno [1 ]
Grosman, Andre [1 ]
Esposito, Basilio [2 ]
Moro, Fabio [2 ]
Morocco, Daniele [2 ]
Villari, Rosaria [2 ]
Angelone, Maurizio [2 ]
Rincon, Esther [3 ]
Hidalgo, Carlos [3 ]
Nagy, Daniel [4 ]
Kocsis, Gabor [4 ]
Varela, Paulo [5 ]
Porempovics, Gabor [6 ]
Perrollaz, Guillaume [7 ]
Patel, Kunal [8 ]
Krivchenkov, Yuri [8 ]
Walsh, Michael [9 ]
机构
[1] CEA, IRFM, F-13108 St Paul Les Durance, France
[2] ENEA, CR Frascati, I-00044 Rome, Italy
[3] CIEMAT, E-28040 Madrid, Spain
[4] RMKI, WIGNER RCP, H-1121 Budapest, Hungary
[5] IPFN, IST, P-1049001 Lisbon, Portugal
[6] BME MM, H-1111 Budapest, Hungary
[7] AMETRA, F-13770 Venelles, France
[8] CCFE, Culham Sci Ctr, Abingdon OX14 3DB, Oxon, England
[9] ITER Org, F-13115 St Paul Les Durance, France
基金
英国工程与自然科学研究理事会;
关键词
ITER; Port plugs; Diagnostics; Integration; Shield modules;
D O I
10.1016/j.fusengdes.2013.02.062
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Diagnostics in ITER are mandatory to characterize the parameters of plasma and study its interactions with plasma-facing components. Diagnostics components in the vicinity of the plasma are supported by metallic structures called port plugs. At the tokamak mid-plane, these components are installed in port plugs through intermediate structures called drawers. Apart from hosting the diagnostics, the port plugs act as shielding against neutrons and gammas, in order to limit the nuclear loads in crucial components (such as diagnostics and superconducting coils) as well as the dose levels in the controlled zones of the tokamak. The radiation shielding function of the port plugs is ensured through an optimized mixture of heavy metallic materials and water, forming shielding blocks surrounding the diagnostics and called Diagnostic Shield Modules (DSMs). These DSMs constitute the rear part of the drawers (the front part being composed of the Diagnostic First Wall). This paper presents the main results of a study performed in Europe on the integration of a particular diagnostics port plug, the Equatorial Port Plug 1 (EPP1). The paper first provides the results of the EPPI diagnostics integration analysis. In a second step it focuses on the design of the EPPI DSMs and summarizes the major results of a thorough set of analyses aiming at studying the DSMs behaviour under different loads, suggesting recommendations to improve their current design. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:602 / 606
页数:5
相关论文
共 4 条
[1]   Neutronic analysis of the ITER Equatorial Port Plug 1 [J].
Moro, F. ;
Esposito, B. ;
Brolatti, G. ;
Marocco, D. ;
Villari, R. ;
Salasca, S. ;
Cantone, B. ;
Dapena-Febrer, M. ;
Petrizzi, L. .
FUSION ENGINEERING AND DESIGN, 2012, 87 (7-8) :1224-1229
[2]  
Pitcher C. S., SOFT 2012 IN PRESS
[3]   Concept development for the ITER equatorial port visible/infrared wide angle viewing system [J].
Reichle, R. ;
Beaumont, B. ;
Boilson, D. ;
Bouhamou, R. ;
Direz, M. -F. ;
Encheva, A. ;
Henderson, M. ;
Huxford, R. ;
Kazarian, F. ;
Lamalle, Ph. ;
Lisgo, S. ;
Mitteau, R. ;
Patel, K. M. ;
Pitcher, C. S. ;
Pitts, R. A. ;
Prakash, A. ;
Raffray, R. ;
Schunke, B. ;
Snipes, J. ;
Diaz, A. Suarez ;
Udintsev, V. S. ;
Walker, C. ;
Walsh, M. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10)
[4]   Progress on the Integration of ITER Diagnostics Equatorial Port Plugs in Europe [J].
Salasca, Sophie ;
Cantone, Bruno ;
Dapena, Miguel ;
Joanny, Maryline ;
Aumeunier, Marie-Helene ;
Travere, Jean-Marcel ;
Esposito, Basilio ;
Moro, Fabio ;
Marocco, Daniele ;
Villari, Rosaria ;
Brolatti, Giorgio ;
Rincon, Esther ;
Varela, Paulo ;
Nagy, Daniel ;
Nemeth, Jozsef ;
Zeile, Christian ;
Perrollaz, Guillaume .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2012, 40 (03) :665-672