The Effect of Flow Rate and Size of Water Droplets on the Water Treatment by Pulsed Discharge in Air
被引:4
|
作者:
Sugai, Taichi
论文数: 0引用数: 0
h-index: 0
机构:
Nagaoka Univ Technol, Extreme Energy Dens Inst, Nagaoka, Niigata 9402188, JapanNagaoka Univ Technol, Extreme Energy Dens Inst, Nagaoka, Niigata 9402188, Japan
Sugai, Taichi
[1
]
Phan Trong Nguyen
论文数: 0引用数: 0
h-index: 0
机构:
Nagaoka Univ Technol, Extreme Energy Dens Inst, Nagaoka, Niigata 9402188, JapanNagaoka Univ Technol, Extreme Energy Dens Inst, Nagaoka, Niigata 9402188, Japan
Phan Trong Nguyen
[1
]
Tokuchi, Akira
论文数: 0引用数: 0
h-index: 0
机构:
Nagaoka Univ Technol, Extreme Energy Dens Inst, Nagaoka, Niigata 9402188, Japan
Pulsed Power Japan Lab, Kusatsu 5250032, JapanNagaoka Univ Technol, Extreme Energy Dens Inst, Nagaoka, Niigata 9402188, Japan
Tokuchi, Akira
[1
,2
]
Jiang, Weihua
论文数: 0引用数: 0
h-index: 0
机构:
Nagaoka Univ Technol, Extreme Energy Dens Inst, Nagaoka, Niigata 9402188, JapanNagaoka Univ Technol, Extreme Energy Dens Inst, Nagaoka, Niigata 9402188, Japan
Jiang, Weihua
[1
]
Minamitani, Yasushi
论文数: 0引用数: 0
h-index: 0
机构:
Yamagata Univ, Yonezawa, Yamagata 9928510, JapanNagaoka Univ Technol, Extreme Energy Dens Inst, Nagaoka, Niigata 9402188, Japan
Minamitani, Yasushi
[3
]
机构:
[1] Nagaoka Univ Technol, Extreme Energy Dens Inst, Nagaoka, Niigata 9402188, Japan
[2] Pulsed Power Japan Lab, Kusatsu 5250032, Japan
[3] Yamagata Univ, Yonezawa, Yamagata 9928510, Japan
For a water treatment method that sprays waste water droplets into a pulsed discharge space, the effect of the flow rate and size of water droplets was investigated by experiments to investigate the optimum spraying method. Indigo carmine solution was decomposed at the flow rate of water from 3 to 12 L/min and the decomposition amount for energy consumed in a reactor was measured. When the flow rate was 3 L/min, the energy yield was lower because the amount of water passing through the ozone space was little. When the flow rate was from 6 to 12 L/min, the energy yield was similar because the ozone dissolved in water was saturated. Furthermore, the water treatment was performed by water droplets of different sizes. Size of the water droplets was varied by varying the diameter of holes of a nozzle. Two nozzles that have holes of 0.3 or 1.8 mm in diameter were used for the experiment. When the flow rate was same, the variation of size of the water droplets does not affect the energy efficiency. From this result, it is considered that the concentration of ozone and hydroperoxyl radicals in water does not depend on the diameter of water droplets. Above results show that the flow rate needs to be increased until the saturation of ozone for the treatment of high energy yield.