关键词
Bluetooth Low Energy; performance assessment; mobile communications; tele-monitoring; mobile monitoring; clinical technology; continuous data transmission; performance; Internet of Things; electrocardiogram;
D O I
暂无
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
Bluetooth Low Energy (BLE) is extending Bluetooth technology to devices with lower communication requirements and higher constraints in terms of memory capabilities and power autonomy. Thereby, BLE makes feasible the wireless transmission of information from smart objects such as wearable clinical devices, ambient sensors and actuators. These smart objects are starting to be internet-enabled devices, reaching the so denominated Internet of Things (IoT). Our research work is focused on analyze the capabilities of these technologies for continuous data transmission and integration of clinical sensors in home-care and Ambient Assisted Living environments. For this purpose, this work analyses exhaustively the capabilities from BLE and compare this with the capabilities from Bluetooth 2.1. In addition, it has been considered the communications requirements from different clinical devices such as an electrocardiogram (ECG) and a capnograph. It is concluded that the performance from BLE is lower than Bluetooth Classic (Bluetooth 2.1) for continuous communications, since BLE is based on attributes (datapoints) transfer instead of offering a communication session where can be transmitted as much packets as required, without any size constraint. Therefore, it is necessary to perform data compression/aggregation when the amount of data to send is too large to be stored in a BLE attribute. This work also presents how to apply pre-processing techniques that greatly reduces the transmission overload (performs signal compression) in order to allow the continuous transmission of the ECG and capnograph signal through BLE making so feasible the integration of continuous clinical devices via BLE.
引用
收藏
页码:1219 / 1241
页数:23
相关论文
共 23 条
  • [1] [Anonymous], 2012, AN092 TEX INSTR
  • [2] Bluegiga, 2010, CLASSIC BLUETOOTH VS
  • [3] Bluegiga, 2012, BLE112 BLUETOOTH LOW
  • [4] Using a Communication Model to Collect Measurement Data through Mobile Devices
    Bravo, Jose
    Villarreal, Vladimir
    Hervas, Ramon
    Urzaiz, Gabriel
    [J]. SENSORS, 2012, 12 (07) : 9253 - 9272
  • [5] Campo C, 2006, J UNIVERS COMPUT SCI, V12, P340
  • [6] Continua: An interoperable personal Healthcare ecosystem
    Carroll, Randy
    Cnossen, Rick
    Schnell, Mark
    Simons, David
    [J]. IEEE PERVASIVE COMPUTING, 2007, 6 (04) : 90 - 94
  • [7] Castro M., 2011, 5 INT S UB COMP AMB
  • [8] Choi J.M., 2004, IEMBS 04 26 ANN INT, V2, P23362, DOI [10.1109/IEMBS.2004.1403944, DOI 10.1109/IEMBS.2004.1403944]
  • [9] Istepanian R.S.H., 2010, AMA IEEE MED TECH C
  • [10] Optimal zonal wavelet-based ECG data compression for a mobile telecardiology system
    Istepanian, RSH
    Petrosian, AA
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2000, 4 (03): : 200 - 211