Nickel/Copper nanoparticles modified TiO2 nanotubes for non-enzymatic glucose biosensors

被引:168
|
作者
Li, Xiaoling [2 ]
Yao, Jianyu [2 ]
Liu, Feila [2 ]
He, Huichao [2 ]
Zhou, Ming [2 ]
Mao, Nan [2 ]
Xiao, Peng [1 ,2 ]
Zhang, Yunhuai [2 ]
机构
[1] Chongqing Univ, Coll Phys, Chongqing 400044, Peoples R China
[2] Chongqing Univ, Coll Chem Engn, Chongqing 400044, Peoples R China
关键词
TiO2 nanotube arrays; Ni-Cu nanoparticles; Non-enzymatic glucose biosensor; Electrocatalysis; CU-NI; ELECTROCATALYTIC OXIDATION; ALLOY ELECTRODES; NICKEL-COPPER; SENSOR; PLATINUM; NANOWIRE; CATALYSTS; FILMS;
D O I
10.1016/j.snb.2013.02.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Highly ordered TiO2 nanotube arrays (TiO2NTs) evenly modified by Ni-Cu nanoparticles were successfully prepared by potential step method. Their morphologies, structures, and alloy composition were characterized by FESEM, XRD and EDS, respectively. The as-prepared Ni-Cu/TiO2NTs electrodes were employed for non-enzymatic glucose detection in alkaline electrolyte and showed better electro-catalytic activity compared with Ni/TiO2NTs and Cu/TiO2NTs electrodes. Factors that affected the electrocatalysis of the electrodes were examined and optimized. Consequently, a sensitive amperometric electrode of glucose was achieved under 0.6V vs. Ag/AgCl with a high sensitivity (1590.9 mu A mM(-1) cm(-2)), low detection limit (5 mu M) and wide linear range from 10 mu M to 3.2 mM (R-2 = 0.993). Furthermore, the oxidable species such as ascorbic acid and uric acid showed no significant interference in determination of glucose. The experiment results revealed a very good reproducibility and high stability for the proposed Ni-Cu/TiO2NTs electrodes. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:501 / 508
页数:8
相关论文
共 50 条
  • [31] Phosphomolybdic acid functionalized graphene loading copper nanoparticles modified electrodes for non-enzymatic electrochemical sensing of glucose
    Xu, Jiaoyan
    Cao, Xiyue
    Xia, Jianfei
    Gong, Shida
    Wang, Zonghua
    Lu, Lin
    ANALYTICA CHIMICA ACTA, 2016, 934 : 44 - 51
  • [32] Uniform and dense copper nanoparticles directly modified indium tin oxide electrode for non-enzymatic glucose sensing
    Wei, Chenhuinan
    Liu, Yahua
    Liu, Qiming
    Xiang, Wei
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 835 : 273 - 280
  • [33] Nickel oxide Nanoparticles/Carbon Nanotubes Nanocomposite for Non-enzymatic Determination of Hydrogen Peroxide
    Fernandez, Inigo
    Carinelli, Soledad
    Luis Gonzalez-Mora, Jose
    Villalonga, Reynaldo
    Salazar-Carballo, Pedro A.
    ELECTROANALYSIS, 2023, 35 (02)
  • [34] Non-Enzymatic Glucose Sensors for Sensitive Amperometric Detection Based on Simple Method of Nickel Nanoparticles Decorated on Magnetite Carbon Nanotubes Modified Glassy Carbon Electrode
    Nontawong, Nongyao
    Amatatongchai, Maliwan
    Jarujamrus, Purim
    Tamuang, Suparb
    Chairam, Sanoe
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (02): : 1362 - 1376
  • [35] One-step synthesis of copper-platinum nanoparticles modified electrode for non-enzymatic salivary glucose detection
    Wang, Chunhui
    Yang, Xiutao
    Zhu, Guopeng
    Wang, Tianye
    Yu, Dengbin
    Lu, Yongzheng
    Yu, Hongwen
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2023, 658
  • [36] Photochemical Activation of Non-enzymatic Sensors Based on Cu/TiO2
    Espro, C.
    Leonardi, S. G.
    Marini, S.
    Neri, G.
    Tobaldi, D. M.
    SENSORS AND MICROSYSTEMS, AISEM 2019, 2020, 629 : 195 - 200
  • [37] A Non-Enzymatic Glucose Sensor based on Copper Oxide Nanowires-SingleWall Carbon Nanotubes
    Bao, Jing
    Hou, Changjun
    Zhang, Yuchan
    Li, Qiong
    Huo, Danqun
    Yang, Mei
    Luo, Xiaogang
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2015, 162 (03) : B47 - B51
  • [38] Non-Enzymatic Graphene-Based Biosensors for Continous Glucose Monitoring
    Sakr, Mahmoud A.
    Serry, Mohamed
    2015 IEEE SENSORS, 2015, : 938 - 941
  • [39] Gold nanoparticles directly modified glassy carbon electrode for non-enzymatic detection of glucose
    Chang, Gang
    Shu, Honghui
    Ji, Kai
    Oyama, Munetaka
    Liu, Xiong
    He, Yunbin
    APPLIED SURFACE SCIENCE, 2014, 288 : 524 - 529
  • [40] Carbon nanoparticles based non-enzymatic glucose sensor
    Pulidindi, Indra Neel
    Gedanken, Aharon
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2014, 94 (01) : 28 - 35