The Application of Intermittent Pneumatic Compression Devices for Thromboprophylaxis An observational study found frequent errors in the application of these mechanical devices in ICUs

被引:14
|
作者
Elpern, Ellen [1 ]
Killeen, Kathryn [1 ]
Patel, Gourang [1 ]
Senecal, Pol Andre [1 ]
机构
[1] Rush Univ, Med Ctr, Chicago, IL 60612 USA
关键词
critical care; deep vein thrombosis; intermittent pneumatic compression devices; mechanical ventilation; pulmonary embolism; thromboprophylaxis; venous thromboembolism; DEEP-VEIN THROMBOSIS; CRITICALLY-ILL PATIENTS; VENOUS THROMBOSIS; PULMONARY-EMBOLISM; RISK-FACTORS; PREVENTION; PROPHYLAXIS; THROMBOEMBOLISM; METAANALYSIS; PREVALENCE;
D O I
10.1097/01.NAJ.0000428736.48428.10
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Objective: Because venous thromboembolism (VTE) can be a devastating consequence of critical illness, patients should receive thromboprophylaxis using chemical or mechanical strategies or both. Mechanical strategies such as intermittent pneumatic compression (IPC) devices are in widespread use; this study sought to assess clinicians' adherence to ordered IPC devices in critically ill patients. Methods: A month-long prospective, observational study was conducted in a convenience sample of 108 mechanically ventilated patients in four adult ICUs in an urban academic medical center. Observations of prescribed IPC device applications were made twice daily by nurses using a standardized checklist. Results: Nine hundred sixty-six observations were made of 108 patients, 47 (44%) of whom were ordered to receive thromboprophylaxis with IPC devices alone and 61 (56%) to receive IPC devices in combination with an anticoagulant. Errors in IPC device application were found in 477 (49%) of the observations. Patients received no IPC prophylaxis in 142 (15%) of total observations. In 45 of 342 (13%) of the observations, IPC devices were the only type of thromboprophylaxis ordered. Half of the misapplications related to improper placement of sleeves to legs. Misapplications did not differ in type or frequency between shifts. Implications: The researchers observed frequent misapplications of ordered IPC devices. Future study is necessary to illuminate the consequences of such errors.
引用
收藏
页码:30 / 36
页数:7
相关论文
共 3 条
  • [1] Intermittent pneumatic compression devices combined with anticoagulants for prevention of symptomatic deep vein thrombosis after total knee arthroplasty: a pilot study
    Liu, Pengcheng
    Liu, Junfeng
    Chen, Liyang
    Xia, Kuo
    Wu, Xing
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2017, 13 : 179 - 183
  • [2] Randomized, pilot study of intermittent pneumatic compression devices plus heparin for prevention of venous thromboembolism in patients undergoing craniotomy
    Macdonald, RL
    Amidei, C
    Baron, J
    Weir, B
    Brown, F
    Erickson, RK
    Hekmatpanah, J
    Frim, D
    SURGICAL NEUROLOGY, 2003, 59 (05): : 363 - 374
  • [3] Comparison of Clinical and Physiological Efficacies of Different Intermittent Sequential Pneumatic Compression Devices in Preventing Deep Vein Thrombosis: A Prospective Randomized Study
    Koo, Ki Hyoung
    Choi, Jae-Sung
    Ahn, Ji Hyun
    Kwon, Jae Hyun
    Cho, Keun-Tae
    CLINICS IN ORTHOPEDIC SURGERY, 2014, 6 (04) : 468 - 475