Low-cost hand-held probe for depth-resolved low-coherence interferometry

被引:26
|
作者
Pande, Paritosh [1 ]
Shelton, Ryan L. [1 ]
Monroy, Guillermo L. [1 ,2 ]
Nolan, Ryan M. [1 ]
Boppart, Stephen A. [1 ,2 ,3 ,4 ]
机构
[1] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL USA
[2] Univ Illinois, Dept Bioengn, Urbana, IL USA
[3] Univ Illinois, Dept Elect & Comp Engn, Urbana, IL USA
[4] Univ Illinois, Dept Internal Med, Urbana, IL USA
来源
BIOMEDICAL OPTICS EXPRESS | 2017年 / 8卷 / 01期
关键词
TYMPANIC MEMBRANE; THICKNESS DISTRIBUTION; TOMOGRAPHY SYSTEM; SWEPT SOURCE;
D O I
10.1364/BOE.8.000338
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report on the development of a low-cost hand-held low-coherence interferometric imaging system based on the principle of linear optical coherence tomography (Linear OCT), a technique which was first proposed in the early 2000s as a simpler alternative to the conventional time-domain and Fourier-domain OCT. A bench-top implementation of the proposed technique is first presented and validated. The axial resolution, SNR, and sensitivity roll-of of the system was estimated to be 5.2 mu m and 80 dB, and 3.7 dB over a depth of 0.15 mm, respectively. After validating the bench-top system, two hand-held probe implementations for contact-based imaging and in vivo human tympanic membrane imaging are presented. The performance of the proposed system was compared with a research-grade state-of-the-art Fourier-domain low coherence interferometry (LCI) system by imaging several biological and non-biological samples. The results of this study suggest that the proposed system might be a suitable choice for applications where imaging depth and SNR can be traded for lower cost and simpler optical design. (C) 2016 Optical Society of America
引用
收藏
页码:338 / 348
页数:11
相关论文
共 50 条
  • [31] Light source for low-coherence interferometry and imaging
    Sverdlov, MI
    Akchurin, GG
    Alaverdyan, SA
    Andrushkevich, TA
    Zimnyakov, DA
    Kuznetsova, OA
    Mishin, AA
    Mikaelyan, GT
    Sokolov, SN
    Stepuhovich, AV
    Tuchin, VV
    COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS II, PROCEEDINGS OF, 1998, 3251 : 273 - 277
  • [32] Semiconductor line source for low-coherence interferometry
    Zvyagin, AV
    Garcia-Webb, MG
    Sampson, DD
    APPLIED OPTICS, 2001, 40 (06) : 913 - 915
  • [33] Real-time, micrometer depth-resolved imaging by low-coherence reflectometry and a two-dimensional heterodyne detection technique
    Akiba, M
    Chan, KP
    Tanno, N
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 2000, 39 (11B): : L1194 - L1196
  • [34] MEASUREMENT OF CORNEAL THICKNESS BY LOW-COHERENCE INTERFEROMETRY
    HITZENBERGER, CK
    APPLIED OPTICS, 1992, 31 (31): : 6637 - 6642
  • [35] Self-mixing low-coherence interferometry
    Rovati, L
    Musatti, G
    Docchio, F
    BIOMEDICAL SYSTEMS AND TECHNOLOGIES II, PROCEEDINGS OF, 1998, 3199 : 268 - 272
  • [36] Ultraprecise measurement of low-coherence interferometry spectrum
    Zhang, Xuezhi
    Liu, Tiegen
    Jiang, Junfeng
    Liu, Kun
    2013 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTICAL SENSORS AND APPLICATIONS, 2013, 9044
  • [37] Applications of low-coherence interferometry in fiber optics
    Hlubina, P
    LIGHTMETRY: METROLOGY, SPECTROSCOPY, AND TESTING TECHNIQUES USING LIGHT, 2001, 4517 : 259 - 266
  • [38] Low-coherence optical fibre speckle interferometry
    Balboa, I.
    D Ford, H.
    Tatam, R. P.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (04) : 605 - 616
  • [39] LOW-COHERENCE INTERFEROMETRY IN CORONARY-ARTERIES
    CHORNENKY, VI
    CORONARY ARTERY DISEASE, 1995, 6 (05) : 377 - 380
  • [40] Characterization of random media by low-coherence interferometry
    Thurber, SR
    Brodsky, AM
    Burgess, LW
    APPLIED SPECTROSCOPY, 2000, 54 (10) : 1506 - 1514