共 32 条
Experimental investigation and thermal analysis of a double slope long still: study of heat and mass transfer
被引:1
作者:
Dumka, Pankaj
[1
]
Mishra, Dhananjay R.
[1
]
机构:
[1] Jaypee Univ Engn & Technol, Dept Mech Engn, Guna, India
关键词:
Desalination;
Double slope;
Long still;
Energy analysis;
Hot wastewater utilisation;
WASTE HEAT;
SOLAR-STILL;
DESALINATION;
ENERGY;
EXERGY;
DRIVEN;
DESIGN;
EARTH;
D O I:
10.1080/01430750.2020.1818128
中图分类号:
TE [石油、天然气工业];
TK [能源与动力工程];
学科分类号:
0807 ;
0820 ;
摘要:
Water, which is used as a cooling agent in various thermal power-based industries, is utilised for the extraction of heat from numerous equipments. Extracted energy need to be discharged in ambient by using chiller/cooling devices for the recirculation of water. The utilisation of this discharged energy for distillation can enhance the overall efficiency of such industries. Proposed double slope long still (DSLS) can be utilised in enlarge scale in between the discharge and cooling/chiller units, for the utilisation of energy present in the hot wastewater to get distillate. Experimental and numerical evaluations have been carried out and reported in this manuscript. It has been observed that the evaporative heat transfer coefficient gets reduced by 64.39% from the inlet to the exit of DSLS. Whereas the energy fractions viz. evaporative, radiative and convective are reduced and increased by 18.38% and 89.80% & 92.18%, respectively. The theoretical results are in good agreement with the experiments.
引用
收藏
页码:3266 / 3274
页数:9
相关论文