Analysis of building plumbing system flushing practices and communications

被引:8
作者
Ragain, Lisa [1 ]
Masters, Sheldon [2 ]
Bartrand, Timothy A. [2 ]
Clancy, Jennifer L. [3 ]
Whelton, Andrew J. [4 ,5 ]
机构
[1] Metropolitan Washington Council Govt, 777 North Capitol St NE 300, Washington, DC 20002 USA
[2] Corona Environm Consulting LLC, 4012 Ridge Ave, Philadelphia, PA 19129 USA
[3] Environm Sci Policy & Res Inst, 4012 Ridge Ave, Philadelphia, PA 19129 USA
[4] Purdue Univ, Div Environm & Ecol Engn, 550 Stadium Mall Dr, W Lafayette, IN 47907 USA
[5] Purdue Univ, Lyles Sch Civil Engn, 550 Stadium Mall Dr, W Lafayette, IN 47907 USA
关键词
drinking water; flushing; guidance; readability; HUMAN EXPOSURE; WATER; READABILITY; CONTAMINATION; CHEMICALS; INDOOR; AIR;
D O I
10.2166/wh.2019.024
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Drinking water distribution system contamination incidents can prompt public agencies and drinking water utilities to issue do-not-drink and do-not-use advisories. After the contaminant is cleared from distribution mains, consumers are often directed to flush their plumbing. However, little validated guidance and few evaluated communications strategies are available on using flushing to decontaminate building water systems. Additionally, limited data support the effectiveness of current practices and recommendations. In this study, expert elicitation was used to assess existing flushing guidance and develop validated flushing guidance and communications for single-family residences. The resulting guidance recommends progressively opening all cold-water taps from the closest to point of entry to the furthest and allowing the water to run for at least 20 minutes. Hot-water taps should be opened progressively and run for at least 75 minutes. The guidance language and format conformed to grade-level and readability scores within recommended health communication ranges. The readability of eight other flushing guidance documents was also evaluated for contamination incidents from 2008-2015. Seven were written at a 10th-12th grade level, above the 6th-7th grade level recommended for health communications.
引用
收藏
页码:196 / 203
页数:8
相关论文
共 42 条
  • [21] Lindell M.K., 2018, HDB DISASTER RES, P449, DOI DOI 10.1007/978-3-319-63254-4_22
  • [22] Community Needs Assessment After Microcystin Toxin Contamination of a Municipal Water Supply - Lucas County, Ohio, September 2014
    McCarty, Carolyn L.
    Nelson, Leigh
    Eitniear, Samantha
    Zgodzinski, Eric
    Zabala, Amanda
    Billing, Laurie
    DiOrio, Mary
    [J]. MMWR-MORBIDITY AND MORTALITY WEEKLY REPORT, 2016, 65 (35): : 925 - 929
  • [23] Volatilization of chemicals from tap water to indoor air from contaminated water used for showering
    Moya, J
    Howard-Reed, C
    Corsi, RL
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (14) : 2321 - 2327
  • [24] *NAT RES COUNC, 2006, DRINK WAT DISTR SYST
  • [25] National Institutes of Health, 2013, WRIT EAS TO READ HLT
  • [26] Ogino C.H., 2012, OPFLOW, V38, P10, DOI [10.5991/opf.2012.38.0014, DOI 10.5991/OPF.2012.38.0014]
  • [27] Subtleties of human exposure and response to chemical mixtures from spills
    Phetxumphou, Katherine
    Dietrich, Andrea M.
    Shanaiah, Narasimhamurthy
    Smiley, Elizabeth
    Gallagher, Daniel L.
    [J]. ENVIRONMENTAL POLLUTION, 2016, 214 : 618 - 626
  • [28] Raucher R., 2014, IDENTIFYING GAPS UND
  • [29] Rosen J., 2014, WV TAP FINAL REPORT
  • [30] An evaluation of the readability of drinking water quality reports: a national assessment
    Roy, Siddhartha
    Phetxumphou, Katherine
    Dietrich, Andrea M.
    Estabrooks, Paul A.
    You, Wen
    Davy, Brenda M.
    [J]. JOURNAL OF WATER AND HEALTH, 2015, 13 (03) : 645 - 653