Blood pressure in Danish children during general anaesthesia: Hypotension in a paediatric population observational (HIPPO) study

被引:4
作者
Clausen, Nicola G. [1 ]
Filipovic, Maja [2 ]
de Pater, Gerrit H. [3 ]
Zickerman, Caroline [4 ]
Ydemann, Mogens [2 ]
机构
[1] Odense Univ Hosp, Sect Paediat Anaesthesia, Anaesthesiol & Intens Care, Odense, Denmark
[2] Rigshosp, Dept Neuroanesthesiol & Intens Care, Copenhagen, Denmark
[3] Haukeland Hosp, Dept Anesthesiol & Intens Care, Bergen, Norway
[4] Umea Univ, Dept Surg & Perioperat Sci, Anesthesiol & Intens Care Med, Umea, Sweden
关键词
SEVOFLURANE ANESTHESIA; INFANTS; OXYGENATION; PERFUSION; YOUNGER; COHORT; IMPACT;
D O I
10.1111/aas.13662
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background In Denmark, thousands of infants and children require general anaesthesia annually. Hypotension during general anaesthesia might reduce cerebral blood flow and oxygen delivery to the brain. Safe lower limits of blood pressure are ill defined. TheHypotension in Paediatric Populations Observationalstudy objective was to assess blood pressure in Danish children during general anaesthesia. Methods This study is a prospective observational multicentre study. Primary outcomes were mean arterial blood pressures in children aged 0-12 years. Lowest mean arterial blood pressure, intervention thresholds to increase blood pressure and type of intervention were secondary outcomes. Premature infants and children scheduled for cardio-thoracic surgery were excluded. Blood pressures were measured by oscillometry or invasively. Results In total, 726 patients were included. In children < 1 year, median arterial pressure was 51 mm Hg, (interquartile range; 43-58) and increased to 58 mm Hg (interquartile range; 52-65) for 12-year-old children. In 32 patients, 49 actions were taken to modulate blood pressure. Pre-induction blood pressures were recorded for 29%. Conclusion This study presents pragmatic, multicentre, prospectively collected observations of blood pressure in children undergoing general anaesthesia in usual practice. In the youngest infants, variability in blood pressure appears to be large. Measurement of blood pressure is recommended during every general anaesthesia and in children of all ages. Safe ranges of blood pressure remain to be defined.
引用
收藏
页码:1453 / 1459
页数:7
相关论文
共 15 条
  • [11] Impact of sevoflurane anesthesia on cerebral blood flow in children younger than 2years
    Rhondali, Ossam
    Mahr, Aurelie
    Simonin-Lansiaux, Sabine
    De Queiroz, Mathilde
    Rhzioual-Berrada, Khalid
    Combet, Sylvie
    Cejka, Jean-Christophe
    Chassard, Dominique
    [J]. PEDIATRIC ANESTHESIA, 2013, 23 (10) : 946 - 951
  • [12] Effects of moderate and severe arterial hypotension on intracerebral perfusion and brain tissue oxygenation in piglets
    Ringer, S. K.
    Clausen, N. G.
    Spielmann, N.
    Ohlerth, S.
    Schwarz, A.
    Weiss, M.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2018, 121 (06) : 1308 - 1315
  • [13] Perioperative Hypotension in Infants: Insights From the GAS Study
    Vutskits, Laszlo
    Skowno, Justin
    [J]. ANESTHESIA AND ANALGESIA, 2017, 125 (03) : 719 - 720
  • [14] Ensuring safe anaesthesia for neonates, infants and young children: what really matters
    Weiss, M.
    Hansen, T. G.
    Engelhardt, T.
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 2016, 101 (07) : 650 - 652
  • [15] Intraoperative blood pressure and cerebral perfusion: strategies to clarify hemodynamic goals
    Williams, Monica
    Lee, Jennifer K.
    [J]. PEDIATRIC ANESTHESIA, 2014, 24 (07) : 657 - 667