Coronary Stent Implantation Technique: Prolonged Inflation Time Maximizes Stent Expansion

被引:0
|
作者
Saha, Mrinal [1 ]
Poliacikova, Petra [1 ]
de Belder, Adam [1 ]
Holmberg, Stephen [1 ]
Clarke, Michael [1 ]
Rajani, Ronak [1 ]
Hildick-Smith, David [1 ]
机构
[1] Brighton & Sussex Univ Hosp, Sussex Cardiac Ctr, Brighton, E Sussex, England
关键词
stent balloon inflation; minimal luminal diameter; SIROLIMUS-ELUTING STENT; UNDEREXPANSION; THROMBOSIS; RECOIL;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. To determine whether longer periods of stent balloon inflation result in greater minimal luminal diameter (MLD) as measured by quantitative coronary analysis (QCA), and to determine whether measured size correlated with that predicted by pressure-diameter nomograms. Methods. Seventy-four stents were implanted in 52 patients. Stent acquisitions at a steady inflation pressure were taken at 10 s, 30 s, and 60 s. The stent MLD at each of these intervals was measured by QCA. Comparisons were made between (1) stent diameter obtained at these time intervals; and (2) nomogram-predicted pressure-related stent diameters. Results. Measured stent size increased significantly between each time point measured, with the most marked increment in size (0.15 +/- 0.02 mm) observed between 10 s and 30 s (P<.0001), with a smaller but still significant increment between 30 s and 60 s (0.06 +/- 0.02 mm; P=.0034). Although there was good correlation between measured size and expected size at 10 s and 30 s (r(2) = 0.60 and 0.58, respectively), the correlation at 60 s inflation was strongest (r(2) = 0.65). Conclusions. Longer durations of stent inflation increase MLD. A minimum duration of 30 seconds is recommended. However, even after 60 s, the MLD does not match the nomogram-derived expected diameter. J INVASIVE CARDIOL 2013;25(1):28-31
引用
收藏
页码:28 / 31
页数:4
相关论文
共 50 条
  • [31] Optimal Duration of Dual Antiplatelet Therapy After Coronary Stent Implantation
    Witberg, Guy
    Lev, Eli
    Kornowsisi, Ran
    AMERICAN JOURNAL OF CARDIOLOGY, 2015, 116 (10) : 1631 - 1636
  • [32] Safety and effectiveness of sirolimus-eluting stent implantation for in-stent restenosis of the unprotected left main coronary artery
    Kim, Hyun-Sook
    Kim, Young-Hak
    Lee, Seung-Whan
    Park, Duk-Woo
    Lee, Cheol Whan
    Hong, Myeong-Ki
    Kim, Jae-Joong
    Park, Seong-Wook
    Park, Seung-Jung
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 124 (01) : 118 - 120
  • [33] Significant Association of Coronary Artery Calcification in Stent Delivery Route With Restenosis After Sirolimus-Eluting Stent Implantation
    Mori, Shumpei
    Yasuda, Satoshi
    Kataoka, Yu
    Morii, Isao
    Kawamura, Atsushi
    Miyazaki, Shunichi
    CIRCULATION JOURNAL, 2009, 73 (10) : 1856 - 1863
  • [34] Update on interventional cardiology: outcome according to stent type and implantation technique
    Luscher, Thomas F.
    EUROPEAN HEART JOURNAL, 2016, 37 (45) : 3359 - 3361
  • [35] Acute coronary syndrome is an independent risk factor for late incomplete stent apposition after sirolimus-eluting stent implantation
    Zhang Rui-yan
    Du Run
    Zhu Zheng-bin
    Zhang Qi
    Hu Jian
    Lue An-kang
    Zhang Jian-sheng
    Shen Wei-feng
    CHINESE MEDICAL JOURNAL, 2008, 121 (24) : 2504 - 2508
  • [36] Independent predictors of in-stent restenosis after drug-eluting stent implantation for ostial right coronary artery lesions
    Watanabe, Yusuke
    Takagi, Kensuke
    Naganuma, Toru
    Kawamoto, Hiroyoshi
    Fujino, Yusuke
    Ishiguro, Hisaaki
    Tahara, Satoko
    Kurita, Naoyuki
    Hosawa, Koji
    Nakamura, Shotaro
    Nakamura, Sunao
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 240 : 108 - 113
  • [37] New Stent Implantation for Recurrences After Stenting for In-Stent Restenosis Implications of a Third Metal Layer in Human Coronary Arteries
    Alfonso, Fernando
    Garcia, Javier
    Perez-Vizcayno, Maria-Jose
    Hernando, Lorenzo
    Hernandez, Rosana
    Escaned, Javier
    Jimenez-Quevedo, Pilar
    Banuelos, Camino
    Macaya, Carlos
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (11) : 1036 - 1038
  • [38] Stent thrombosis following bare-metal stent implantation:: success of emergency percutaneous coronary intervention and predictors of adverse outcome
    Wenaweser, P
    Rey, C
    Eberli, FR
    Togni, M
    Tüller, D
    Locher, S
    Remondino, A
    Seiler, C
    Hess, OM
    Meier, B
    Windecker, S
    EUROPEAN HEART JOURNAL, 2005, 26 (12) : 1180 - 1187
  • [39] A history of early stent thrombosis is associated with prolonged clot lysis time
    Pankiw-Bembenek, Oksana
    Zalewski, Jaroslaw
    Goralczyk, Tadeusz
    Undas, Anetta
    THROMBOSIS AND HAEMOSTASIS, 2012, 107 (03) : 513 - 520
  • [40] Problems of long-term antiplatelet therapy after coronary stent implantation
    Kubica, Aldona
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2009, 5 (03): : 158 - 161