Coronary Stent Implantation Technique: Prolonged Inflation Time Maximizes Stent Expansion

被引:0
|
作者
Saha, Mrinal [1 ]
Poliacikova, Petra [1 ]
de Belder, Adam [1 ]
Holmberg, Stephen [1 ]
Clarke, Michael [1 ]
Rajani, Ronak [1 ]
Hildick-Smith, David [1 ]
机构
[1] Brighton & Sussex Univ Hosp, Sussex Cardiac Ctr, Brighton, E Sussex, England
关键词
stent balloon inflation; minimal luminal diameter; SIROLIMUS-ELUTING STENT; UNDEREXPANSION; THROMBOSIS; RECOIL;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. To determine whether longer periods of stent balloon inflation result in greater minimal luminal diameter (MLD) as measured by quantitative coronary analysis (QCA), and to determine whether measured size correlated with that predicted by pressure-diameter nomograms. Methods. Seventy-four stents were implanted in 52 patients. Stent acquisitions at a steady inflation pressure were taken at 10 s, 30 s, and 60 s. The stent MLD at each of these intervals was measured by QCA. Comparisons were made between (1) stent diameter obtained at these time intervals; and (2) nomogram-predicted pressure-related stent diameters. Results. Measured stent size increased significantly between each time point measured, with the most marked increment in size (0.15 +/- 0.02 mm) observed between 10 s and 30 s (P<.0001), with a smaller but still significant increment between 30 s and 60 s (0.06 +/- 0.02 mm; P=.0034). Although there was good correlation between measured size and expected size at 10 s and 30 s (r(2) = 0.60 and 0.58, respectively), the correlation at 60 s inflation was strongest (r(2) = 0.65). Conclusions. Longer durations of stent inflation increase MLD. A minimum duration of 30 seconds is recommended. However, even after 60 s, the MLD does not match the nomogram-derived expected diameter. J INVASIVE CARDIOL 2013;25(1):28-31
引用
收藏
页码:28 / 31
页数:4
相关论文
共 50 条
  • [1] Impact of the Balloon Inflation Time and Pattern on the Coronary Stent Expansion
    Skowronski, Jaroslaw
    Wolny, Rafal
    Jastrzebski, Jan
    Tyczynski, Pawel
    Szlazak, Karol
    Pregowski, Jerzy
    Mintz, Gary S.
    Lizewska, Karolina
    Swieszkowski, Wojciech
    Chmielak, Zbigniew
    Witkowski, Adam
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2019, 2019
  • [2] Impact of a Prolonged Delivery Inflation Time for Optimal Drug-Eluting Stent Expansion
    Kawasaki, Tomohiro
    Koga, Hisashi
    Serikawa, Takeshi
    Orita, Yoshiya
    Ikeda, Shinsuke
    Mito, Takahiro
    Gotou, Yoshitaka
    Shintani, Yoshiaki
    Tanaka, Atsushi
    Tanaka, Hidenori
    Fukuyama, Takaya
    Koga, Nobuhiko
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 73 (02) : 205 - 211
  • [3] Better stent expansion by two-time inflation of stent balloon and its responsible mechanism
    Iwamoto, Yumiko
    Okamoto, Mitsunori
    Hashimoto, Masaki
    Fukuda, Yukihiro
    Iwamoto, Akimichi
    Iwasaki, Toshitaka
    Kinoshita, Hiroki
    Kihara, Yasuki
    JOURNAL OF CARDIOLOGY, 2012, 59 (02) : 160 - 166
  • [4] Effect of balloon inflation time on expansion of sirolimus-eluting stent
    Asano, Tatsuhiko
    Kobayashi, Yoshio
    Fukushima, Kenichi
    Iwata, Yo
    Kitahara, Hideki
    Ishio, Naoki
    Nakayama, Takashi
    Kuroda, Nakabumi
    Komuro, Issei
    HEART AND VESSELS, 2009, 24 (05) : 335 - 339
  • [5] Improved stent expansion with prolonged compared with short balloon inflation: A meta-analysis
    Saad, Marwan
    Bavineni, Mahesh
    Uretsky, Barry F.
    Vallurupalli, Srikanth
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 92 (05) : 873 - 880
  • [6] Biomechanical Aspects of Potential Stent Malapposition at Coronary Stent Implantation
    Schmidt, W.
    Behrens, P.
    Schmitz, K. -P.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 6, 2009, 25 : 136 - 139
  • [7] Stent expansion in calcified coronary chronic total occlusions: The impact of different stent platforms
    Scarparo, Paola
    Schermers, Thom
    Improta, Riccardo
    Kardys, Isabella
    Wilschut, Jeroen
    Daemen, Joost
    Nuis, Rutger-Jan
    Den Dekker, Wijnand K. K.
    Van Mieghem, Nicolas M. M.
    Diletti, Roberto
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2023, 102 (03) : 451 - 463
  • [8] Incomplete Stent Apposition after Coronary Stent Implantation: Myth or Reality?
    Rathore, Sudhir
    Terashima, Mitsuyasu
    Habara, M.
    Kinoshita, Yoshihisa
    Nasu, Kenya
    Katoh, Osamu
    Suzuki, Takahiko
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2009, 22 (04) : 341 - 349
  • [9] Ten-Year Clinical Outcomes of Late-Acquired Stent Malapposition After Coronary Stent Implantation
    Lee, Seung-Yul
    Ahn, Jung-Min
    Mintz, Gary S.
    Hong, Sung-Jin
    Ahn, Chul-Min
    Park, Duk-Woo
    Kim, Jung-Sun
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Park, Seung-Jung
    Hong, Myeong-Ki
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2020, 40 (01) : 288 - 295
  • [10] Coronary artery stent fracture with in-stent restenosis and aneurysm formation: Diagnosis and successful treatment with graft stent implantation
    Stambuk, Kresimir
    Pavlovic, Nikola
    Gabric, Ivo Darko
    Krcmar, Tomislav
    Trbusic, Matias
    Manola, Sime
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 148 (02) : 253 - 255