Comparison Over Time of Vault in Chinese Eyes Receiving Implantable Contact Lenses With or Without a Central Hole

被引:18
作者
Cao, Xinfang [1 ]
Wu, Weiliang [2 ]
Wang, Yang [1 ]
Xie, Chen [1 ]
Shen, Ye [1 ]
机构
[1] Zhejiang Univ, Dept Ophthalmol, Affiliated Hosp 1, Coll Med, 79 Qingchun Rd, Hangzhou 310003, Zhejiang, Peoples R China
[2] Zhejiang Univ, Coll Med, Childrens Hosp, Dept Orthoped, Hangzhou, Zhejiang, Peoples R China
关键词
PHAKIC INTRAOCULAR-LENS; ULTRASOUND BIOMICROSCOPY; COLLAMER LENS; MYOPIC EYES; FOLLOW-UP; CATARACT; PRESSURE; POSITION; ASTIGMATISM; MODERATE;
D O I
10.1016/j.ajo.2016.09.016
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the longitudinal vault changes after implantation of a posterior chamber phakic intraocular lens (pIOL) (Visian implantable contact lens) with (ICL V4c) and without (ICL V4) a central artificial hole for moderate to high myopia in Chinese eyes. DESIGN: Retrospective case series. METHODS: This study comprised 78 eyes implanted with the ICL V4c model and 82 eyes implanted with the ICL V4 model at our department by the same surgeon. The time course of the postoperative pIOL vault changes was quantitatively assessed using ultrasound biomicroscopy over 6 months. RESULTS: There was a trend toward a decrease in all measures of central vault, peripheral vault, and the endothelium anterior pIOL distance for both central hole pIOL and conventional pIOL over time, although the variance was not statistically significant (all P > .05). There were no significant between-group differences in the amount of the pIOL central vault, peripheral vault, or the endothelium anterior pIOL distance at any time point after surgery (all P > .05). CONCLUSIONS: The time course of the central hole pIOL vault changes is essentially equivalent to that of the conventional pIOL vault, suggesting that the presence of the central hole did not significantly affect the pIOL position. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:111 / 117
页数:7
相关论文
共 30 条
  • [11] Ultrasound Biomicroscopy of Anterior Segment Accommodative Changes with Posterior Chamber Phakic Intraocular Lens in High Myopia
    Du, Chixin
    Wang, Jianhua
    Wang, Xiaoyu
    Dong, Ying
    Gu, Yangshun
    Shen, Ye
    [J]. OPHTHALMOLOGY, 2012, 119 (01) : 99 - 105
  • [12] Changes in objective vault and effect on vision outcomes after implantable Collamer lens implantation: 1-year follow-up
    Du, Gai-Ping
    Huang, Yi-Fei
    Wang, Li-Qiang
    Wang, Da-Jiang
    Guo, Hui-Ling
    Yu, Ji-Feng
    Gong, Yu-Bo
    Song, Jing
    Huang, Hou-Bing
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 (02) : 153 - 160
  • [13] Ciliary sulcus diameters at different anterior chamber depths in highly myopic eyes
    Gao, Jian
    Liao, Rong-Feng
    Li, Ning
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (07) : 1011 - 1016
  • [14] Implantable contact lens for moderate to high myopia - Relationship of vaulting to cataract formation
    Gonvers, M
    Bornet, C
    Othenin-Girard, P
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (05) : 918 - 924
  • [15] Intraocular pressure during the early postoperative period after 100 consecutive implantations of posterior chamber phakic intraocular lenses with a central hole
    Gonzalez-Lopez, Felix
    Bilbao-Calabuig, Rafael
    Mompean, Blas
    de Rojas, Victoria
    Luezas, Jorge
    Reza Djodeyre, Mohammad
    Beltran, Jaime
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (12) : 1859 - 1863
  • [16] Intraocular Pressure after Implantation of the Visian Implantable Col lamer Lens With CentraFLOW Without Iridotomy
    Higueras-Esteban, Alejandro
    Ortiz-Gomariz, Amanda
    Gutierrez-Ortega, Ramon
    Villa-Collar, Cesar
    Abad-Montes, Juan P.
    Fernandes, Paulo
    Gonzalez-Meijome, Jose M.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (04) : 800 - 805
  • [17] Phakic Intraocular Lens Implantation for the Correction of Myopia A Report by the American Academy of Ophthalmology
    Huang, David
    Schallhorn, Steven C.
    Sugar, Alan
    Farjo, Ayad A.
    Majmudar, Parag A.
    Trattler, William B.
    Tanzer, David J.
    [J]. OPHTHALMOLOGY, 2009, 116 (11) : 2244 - 2258
  • [18] Comparative Study of 2 Types of Implantable Collamer Lenses, 1 With and 1 Without a Central Artificial Hole
    Huseynova, Tukezban
    Ozaki, Shu
    Ishizuka, Tatsuya
    Mita, Mariko
    Tomita, Minoru
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (06) : 1136 - 1143
  • [19] Comparison of vault after implantation of posterior chamber phakic intraocular lens with and without a central hole
    Kamiya, Kazutaka
    Shimizu, Kimiya
    Ando, Wakako
    Igarashi, Akihito
    Iijima, Kei
    Koh, Ayaka
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (01) : 67 - 72
  • [20] Changes in vaulting and the effect on refraction after phakic posterior chamber intraocular lens implantation
    Kamiya, Kazutaka
    Shimizu, Kimiya
    Kawamorita, Takushi
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (09) : 1582 - 1586