Agreement between vector analysis and body composition measurements by four types of bioelectrical impedance technology in hemodialysis patients

被引:3
作者
Espinosa-Cuevas, Angeles [1 ]
Ch-Duran, Larisa-Ximena [2 ]
Atilano-Carsi, Ximena [1 ]
Gonzalez-Ortiz, Ailema [3 ]
Ramos-Acevedo, Samuel [2 ]
Lopez-Cisneros, Sonia [1 ]
Correa-Rotter, Ricardo [1 ]
Vanessa Miranda-Alatriste, Paola [1 ]
机构
[1] Inst Nacl Ciencias Med & Nutr Salvador Zubiran, Nephrol & Mineral Metab Dept, Mexico City, DF, Mexico
[2] Univ Iberoamer, Dept Hlth Sci, Puebla, Mexico
[3] Inst Nacl Pediat, Translat Res Ctr, Mexico City, DF, Mexico
关键词
Bioimpedance vector analysis; Bioimpedance analysis; Body composition; Agreement; Hemodialysis; CHRONIC KIDNEY-DISEASE; X-RAY ABSORPTIOMETRY; BIOIMPEDANCE ANALYSIS; HEART-FAILURE; ANALYSIS BIVA; ANTHROPOMETRY; MALNUTRITION; INFLAMMATION; MORTALITY; WOMEN;
D O I
10.20960/nh.04005
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background: the differences in bioelectrical impedance vector analysis (BIVA) results from different analyzers that use different bioelectrical impedance analysis (BIA) measurement technologies are not known. This study aimed to identify the degree of agreement between the BIVA results of four different BIA measurement techniques and to evaluate the degree of agreement between their estimates of fat-free mass (FFM) and fat mass (FM) and those determined by the gold-standard method of dual-energy X-ray absorptiometry (DEXA) in a subgroup of patients without overhydration.Methods: a cross-sectional study was conducted with hemodialysis (HD) patients with end-stage renal disease (ESRD) aged 18 to 65 years. BIA was measured with four different techniques: spectroscopic (BIA-BIS), multifrequency (BIA-MF), single-frequency (BIA-SF), and segmental multifrequency (BIA-MS) techniques. The differences and concordance between the components of the BIA (resistance, reactance, and phase angle) of the four devices were analyzed. Patients with a normal hydration status were identified, and concordance between FM and FFM measurements with each impedance device and DEXA was observed only in these patients. Results: thirty patients were included. The concordance between the components of BIA ranged from good to excellent (phase angle: intraclass correlation coefficient (ICC) = 0.82, 95 % confidence interval (CI): 0.77-0.93; resistance: ICC = 0.98, 95 % CI: 0.92-0.99). The overall concordance for BIVA diagnosis between the analyzers was substantial for hydration (k = 0.71, 95 % CI: 0.71-0.72) and for body tissues (k = 0.68, 95 % CI: 0.67-0.68). Bland-Altman plots showed the lowest bias between BIA-BIS and DEXA for both FM and FFM. Conclusions: the agreement among the four devices was good for diagnosis by BIVA. The BIA-BIS analyzer and DEXA had the lowest bias for both FFM and FM, although with higher limits of agreement. The lowest limits of agreement were found with the BIA-MS analyzer
引用
收藏
页码:1047 / 1057
页数:11
相关论文
共 41 条
[1]   Update on Inflammation in Chronic Kidney Disease [J].
Akchurin, Oleh M. ;
Kaskel, Frederick .
BLOOD PURIFICATION, 2015, 39 (1-3) :84-92
[2]  
Alvero-Cruz J., 2011, Revista Andaluza de medicina del deporte, V4, P167
[3]   Diagnostic validation and prognostic significance of the Malnutrition-Inflammation Score in nondialyzed chronic kidney disease patients [J].
Amparo, Fernanda C. ;
Kamimura, Maria A. ;
Molnar, Miklos Z. ;
Cuppari, Lilian ;
Lindholm, Bengt ;
Amodeo, Celso ;
Carrero, Juan J. ;
Cordeiro, Antonio C. .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2015, 30 (05) :821-828
[4]   Comparison between dual-energy x-ray absorptiometry and bioelectrical impedance for body composition measurements in adults with chronic kidney disease: A cross-sectional, longitudinal, multi-treatment analysis [J].
Bellafronte, Natalia Tomborelli ;
Diani, Luisa Maria ;
Vega-Piris, Lorena ;
Barril Cuadrado, Guillermina ;
Chiarello, Paula Garcia .
NUTRITION, 2021, 82
[5]   Bioimpedance vector analysis in stable chronic heart failure patients: Level of agreement between single and multiple frequency devices [J].
Bernal-Ceballos, Fernanda ;
Wacher-Rodarte, Niels H. ;
Orea-Tejeda, Arturo ;
Hernandez-Gilsoul, Thierry ;
Castillo-Martinez, Lilia .
CLINICAL NUTRITION ESPEN, 2021, 43 :206-211
[6]   Advanced body composition assessment: from body mass index to body composition profiling [J].
Borga, Magnus ;
West, Janne ;
Bell, Jimmy D. ;
Harvey, Nicholas C. ;
Romu, Thobias ;
Heymsfield, Steven B. ;
Leinhard, Olof Dahlqvist .
JOURNAL OF INVESTIGATIVE MEDICINE, 2018, 66 (05) :887-895
[7]   Concordance between muscle mass assessed by bioelectrical impedance analysis and by dual energy X-ray absorptiometry: a cross-sectional study [J].
Buckinx, Fanny ;
Reginster, Jean-Yves ;
Dardenne, Nadia ;
Croisiser, Jean-Louis ;
Kaux, Jean-Francois ;
Beaudart, Charlotte ;
Slomian, Justine ;
Bruyere, Olivier .
BMC MUSCULOSKELETAL DISORDERS, 2015, 16
[8]   Global Prevalence of Protein-Energy Wasting in Kidney Disease: A Meta-analysis of Contemporary Observational Studies From the International Society of Renal Nutrition and Metabolism [J].
Carrero, Juan J. ;
Thomas, Fridtjof ;
Nagy, Kristof ;
Arogundade, Fatiu ;
Avesani, Carla M. ;
Chan, Maria ;
Chmielewski, Michal ;
Cordeiro, Antottio C. ;
Espinosa-Cuevas, Angeles ;
Fiaccadori, Enrico ;
Guebre-Egziabher, Fitsum ;
Hand, Rosa K. ;
Hung, Adriana M. ;
Ikizler, Talat A. ;
Johansson, Lina R. ;
Kalantar-Zadeh, Kamyar ;
Karupaiah, Tilakavati ;
Lindholm, Bengt ;
Marckmann, Peter ;
Mafra, Denise ;
Parekh, Rulan S. ;
Park, Jongha ;
Russo, Sharon ;
Saxena, Anita ;
Sezer, Siren ;
Teta, Daniel ;
Ter Wee, Pieter M. ;
Verseput, Cecile ;
Wang, Angela Y. M. ;
Xu, Hong ;
Lu, Yimin ;
Molnar, Miklos Z. ;
Kovesdy, Csaba P. .
JOURNAL OF RENAL NUTRITION, 2018, 28 (06) :380-392
[9]   Assessment of hydration status using bioelectrical impedance vector analysis in critical patients with acute kidney injury [J].
da Rosa Hise, Ana Claudia ;
Gonzalez, Maria Cristina .
CLINICAL NUTRITION, 2018, 37 (02) :695-700
[10]  
Espinosa-Cuevas MD, 2007, REV INVEST CLIN, V59, P15