Impact Of Diffuser Width On The Performance Of AP1000 Reactor Coolant Pump

被引:1
作者
Yuan, Danqing [1 ]
Yan, Hua [1 ]
Wang, Peipei [1 ]
机构
[1] Jiangsu Univ, Sch Energy & Power Engn, Zhenjiang, Peoples R China
来源
ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2 | 2012年 / 516-517卷
关键词
AP1000 Reactor Coolant Pump; Spherical Diffuser; Numerical Simulation;
D O I
10.4028/www.scientific.net/AMR.516-517.921
中图分类号
O414.1 [热力学];
学科分类号
摘要
For the problem of incapable to determine the width of spherical diffuser, four groups of spherial diffusers with different width were designed by using the speed coefficient method. Numerical investigation of internal flow in the nuclear coolant pumps with these diffusers was made based on ANSYS-CFX software. Aimed at the efficiency, ditribution of pressure and velocity vector on the meridian plane of each volute scheme was analysised emphatically. By comparing the performance curves of the coolant pumps predicted by the numerical simulation, we can draw that the head and efficiency of pump decreased as the increasing of diffuser width and performanced worst at the width of d=1.7R, then the performance no longer changes when diffuser width continue to reduce.
引用
收藏
页码:921 / 925
页数:5
相关论文
共 8 条
  • [1] Guan Xingfan, 1987, THEORY DESIGN PUMP
  • [2] Koai K L, 1990, P INT COMPR ENG C PU, P50
  • [3] [梁武科 LIANG Wuke], 2008, [动力工程, Journal of Power Engineering], V28, P600
  • [4] Qin Wu, 2007, PUMP TECHNOLOGY, V3, P1
  • [5] [吴治将 WU Zhijiang], 2005, [流体机械, Fluid Machinery], V33, P15
  • [6] Decontamination of the reactor coolant pump in Maanshan nuclear power plant
    Yang, IJ
    Teng, MY
    Huan, WI
    Sun, YL
    [J]. NUCLEAR ENGINEERING AND DESIGN, 1996, 167 (01) : 91 - 97
  • [7] Yuan Chunyuan, 2008, T CHINESE SOC AGR MA, V39-3, P52
  • [8] Zhang Peng, 2006, ENERGY CONSERVATION, V5, P25