A bioreactor with an electro-responsive elastomeric membrane for mimicking intestinal peristalsis

被引:21
作者
Cei, Daniele [1 ,2 ]
Costa, Joana [1 ,2 ,3 ]
Gori, Giulia [1 ,2 ]
Frediani, Gabriele [4 ]
Domenici, Claudio [5 ]
Carpi, Federico [6 ]
Ahluwalia, Arti [1 ,2 ]
机构
[1] Univ Pisa, Res Ctr E Piaggio, I-56126 Pisa, Italy
[2] Univ Pisa, Dept Informat Engn, I-56126 Pisa, Italy
[3] IVTech Srl, Via Bagnaia 414, I-55054 Massarosa, Italy
[4] Queen Mary Univ London, Sch Engn Mat Sci, Mile End Rd, London E1 4NS, England
[5] CNR, Inst Clin Physiol, Via G Moruzzi 1, I-56124 Pisa, Italy
[6] Univ Florence, Dept Ind Engn, Via S Marta 3, I-50139 Florence, Italy
基金
欧盟地平线“2020”;
关键词
dielectric elastomer actuator; bioreactor; in vitro model; intestinal contraction; artificial muscle; STRETCHING SYSTEM; STRAIN SYSTEM; IN-VITRO; CELL; DEFORMATION; ACTUATORS; CULTURE;
D O I
10.1088/1748-3190/12/1/016001
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study describes an actuated bioreactor which mimics the pulsatile contractile motion of the intestinal barrier using electro-responsive elastomers as smart materials that undergo deformation upon electrical stimulation. The device consists of an annular dielectric elastomer actuator working as a radial artificial muscle able to rhythmically contract and relax a central cell culture well. The bioreactor maintained up to 4 h of actuation at a frequency of 0.15 Hz and a strain of 8%-10%, to those of the cyclic contraction and relaxation of the small intestine. In vitro tests demonstrated that the device was biocompatible and cell-adhesive for Caco-2 cells, which formed a confluent monolayer following 21 days of culture in the central well. In addition, cellular adhesion and cohesion were maintained after 4 h of continuous cyclic strain. These preliminary results encourage further investigations on the use of dielectric elastomer actuation as a versatile technology that might overcome the limitations of commercially available pneumatic driving systems to obtain bioreactors that can cyclically deform cell cultures in a biomimetic fashion.
引用
收藏
页数:8
相关论文
共 42 条
[1]   Microfabrication and characterization of an array of dielectric elastomer actuators generating uniaxial strain to stretch individual cells [J].
Akbari, S. ;
Shea, H. R. .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2012, 22 (04)
[2]   An array of 100 μm x 100 μm dielectric elastomer actuators with 80% strain for tissue engineering applications [J].
Akbari, Samin ;
Shea, Herbert R. .
SENSORS AND ACTUATORS A-PHYSICAL, 2012, 186 :236-241
[3]  
Bashkin J. S., 2009, BIOMEDICAL APPL ELEC, P395
[4]   Paradigms for mechanical signal transduction in the intestinal epithelium - Category: molecular, cell, and developmental biology [J].
Basson, MD .
DIGESTION, 2003, 68 (04) :217-225
[5]   A cell strain system for small homogeneous strain applications [J].
Bottlang, M ;
Simnacher, M ;
Schmitt, H ;
Brand, RA ;
Claes, L .
BIOMEDIZINISCHE TECHNIK, 1997, 42 (11) :305-309
[6]   Advances in Dielectric Elastomers for Actuators and Artificial Muscles [J].
Brochu, Paul ;
Pei, Qibing .
MACROMOLECULAR RAPID COMMUNICATIONS, 2010, 31 (01) :10-36
[7]   Techniques for mechanical stimulation of cells in vitro: a review [J].
Brown, TD .
JOURNAL OF BIOMECHANICS, 2000, 33 (01) :3-14
[8]  
Carpi F, 2008, DIELECTRIC ELASTOMERS AS ELECTROMECHANICAL TRANSDUCERS: FUNDAMENTALS, MATERIALS, DEVICES, MODELS AND APPLICATIONS OF AN EMERGING ELECTROACTIVE POLYMER TECHNOLOGY, P1
[9]  
Carpi F, 2010, WORLD C MED PHYS BIO, V25/10
[10]  
Carpi F., 2009, BIOMEDICAL APPL ELEC, P1