Comparison of ultrasound-guided versus blind glenohumeral injections: a cadaveric study

被引:55
作者
Patel, Deepan N. [1 ]
Nayyar, Samir [1 ]
Hasan, Saqib [1 ]
Khatib, Omar [1 ]
Sidash, Stanislav [1 ]
Jazrawi, Laith M. [1 ]
机构
[1] NYU, Div Sports Med, Hosp Joint Dis, New York, NY USA
关键词
Glenohumeral; injection; shoulder; ultrasound guided; cadaveric; accuracy; time assessment; INTRAARTICULAR INJECTION; ACCURACY; SHOULDER; JOINT; ARTHROGRAPHY; PLACEMENT;
D O I
10.1016/j.jse.2011.11.026
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Intra-articular glenohumeral (GH) injections are important for diagnostic and therapeutic purposes. It has been suggested that ultrasound guided injections are more accurate than blind or freehand injections. This study assessed the accuracy of ultrasound-guided GH injections compared with freehand injections in fresh cadavers. Methods: The study used 80 shoulder specimens from fresh cadavers. Ultrasound guidance was used to inject radiopaque contrast in 40 shoulders, and freehand technique was used in the remaining 40. All injections were performed by 2 surgeons (A and B) through a posterior approach. After the injections, radiographs were obtained of the specimens to assess the accuracy of the injections. Results: Sixty-six of 80 (82.5%) injections were accurately administered into the GH joint. Ultrasound-guided injections were accurate in 37 of 40 specimens (92.5%) compared with freehand injections, which were accurate in only 29 of 40 specimens (72.5%; P=.02). Both surgeons independently had higher accuracy using ultrasound-guidance compared with the freehand technique (surgeon A: 90% vs 65%, P=0.058; surgeon B: 95% vs 80%, P=0.15). The average time for injections was 52 seconds by the freehand technique and 166 seconds using ultrasound guidance (P<0.001). Conclusions: The data from this cadaveric study suggest that ultrasound-guided injections are more accurate at reaching the GH joint than freehand injections. The ultrasound-guided injections took substantially longer to administer. Once familiar with the technique, surgeons can expect improved accuracy and efficacy of GH joint injections using ultrasound guidance in the clinical setting. Level of evidence: Basic Science Study, Anatomic Study. (C) 2012 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:1664 / 1668
页数:5
相关论文
共 12 条
  • [1] BUTTERS KP, 1988, ORTHOP CLIN N AM, V19, P755
  • [2] CICAK N, 1992, J ULTRAS MED, V11, P135
  • [3] Accuracy of anterior glenohumeral injections: a cadaver study
    Esenyel, Cem Zeki
    Ozturk, Kahraman
    Demirhan, Mehmet
    Sonmez, Mesut
    Kahraman, Sinan
    Esenyel, Meltem
    Ozbaydar, Mehmet Ugur
    Senel, Berna
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (03) : 297 - 300
  • [4] Comparison of the accuracy of steroid placement with clinical outcome in patients with shoulder symptoms
    Eustace, JA
    Brophy, DP
    Gibney, RP
    Bresnihan, B
    FitzGerald, O
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 1997, 56 (01) : 59 - 63
  • [5] Hanchard N, 2006, J RHEUMATOL, V33, P1143
  • [6] KERLAN RK, 1989, CLIN SPORT MED, V8, P541
  • [7] NEVIASER RJ, 1983, CLIN ORTHOP RELAT R, P63
  • [8] Sethi PM, 2006, ORTHOPEDICS, V29, P149, DOI 10.3928/01477447-20060201-01
  • [9] Accuracy of anterior intra-articular injection of the glenohumeral joint
    Sethi, PM
    Kingston, S
    Elattrache, N
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (01) : 77 - 80
  • [10] Accuracy of glenohumeral joint injections: comparing approach and experience of provider
    Tobola, Allison
    Cook, Chad
    Cassas, Kyle J.
    Hawkins, Richard J.
    Wienke, Jeffrey R.
    Tolan, Stefan
    Kissenberth, Michael J.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (07) : 1147 - 1154