Noninvasive measurement of fluorophore concentration in turbid media with a simple fluorescence/reflectance ratio technique

被引:53
|
作者
Weersink, R
Patterson, MS
Diamond, K
Silver, S
Padgett, N
机构
[1] Photon Res Ontario, Biophoton Facil, Toronto, ON M5G 2M9, Canada
[2] McMaster Univ, Hamilton, ON L8V 5C2, Canada
[3] Hamilton Reg Canc Ctr, Hamilton, ON L8V 5C2, Canada
关键词
D O I
10.1364/AO.40.006389
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Measurement of the concentration of fluorescent compounds in turbid media is difficult because the absorption and multiple scattering of excitation and emission of light has a large effect on the detected fluorescence. For surface measurements with optical fibers we demonstrate by experiments and numerical simulation that this effect can be minimized by measurement of the fluorescence at one source-detector distance, the diffusely reflected excitation light at a second distance, and with the ratio of these two signals as an indicator of fluorophore concentration. For optical properties typical of soft tissue in the red and the near infrared the optimum performance is obtained by measurement of fluorescence at 0.65 mm and reflectance at 1.35 mm. This choice reduces the rms error in fluorophore concentration to 14.6% over a wide range of absorption and scattering coefficients. (C) 2001 Optical Society of America.
引用
收藏
页码:6389 / 6395
页数:7
相关论文
共 50 条
  • [21] Noninvasive determination of the optical properties of two-layered turbid media from time-resolved reflectance measurements
    Kienle, A
    Glanzmann, T
    Wagnières, G
    van den Bergh, H
    BIOMEDICAL SENSORS, FIBERS, AND OPTICAL DELIVERY SYSTEMS, PROCEEDINGS, 1999, 3570 : 20 - 27
  • [22] Fluorescence and diffuse reflectance provide similar accuracy in recovering fluorophore concentration at short source-detector separations
    Roccabruna, Jacob R.
    Bridger, Karina G.
    Baran, Timothy M.
    JOURNAL OF MODERN OPTICS, 2022, 69 (12) : 699 - 704
  • [23] Quantification of fluorophore concentration in tissue-simulating media by fluorescence measurements with a single optical fiber
    Diamond, KR
    Patterson, MS
    Farrell, TJ
    APPLIED OPTICS, 2003, 42 (13) : 2436 - 2442
  • [24] A simple measurement of the pH of root apoplast by the fluorescence ratio method
    Nishiyama, Hiroki
    Ohya, Tomoyuki
    Tanoi, Keitaro
    Nakanishi, Tomoko M.
    PLANT ROOT, 2008, 2 : 3 - 6
  • [25] Instrument for Measurement of Optical Parameters of Turbid Media by Using Diffuse Reflectance of Laser With Oblique Incidence Angle
    Juttula, Harri J.
    Kananen, Timo P.
    Makynen, Anssi J.
    2013 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2013, : 1130 - 1134
  • [26] Instrument for Measurement of Optical Parameters of Turbid Media by Using Diffuse Reflectance of Laser With Oblique Incidence Angle
    Juttula, Harri J.
    Kananen, Timo P.
    Makynen, Anssi J.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2014, 63 (05) : 1301 - 1309
  • [27] A SIMPLE TECHNIQUE FOR OBJECTIVE MEASUREMENT AND EVALUATION OF SPERM MOTILITY AND CONCENTRATION
    MALEIKA, F
    SCHAFFER, E
    LAURITZEN, C
    ARCHIVES OF ANDROLOGY, 1980, 5 (01): : 6 - 6
  • [28] Optoacoustic technique for continuous, noninvasive measurement of total hemoglobin concentration: An in vivo study
    Petrova, IY
    Prough, DS
    Petrov, YY
    Brecht, HPF
    Svensen, CH
    Olsson, J
    Dey, DJ
    Esenaliev, RO
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 2059 - 2061
  • [29] Comparison of NIR/RED ratio and first derivative of reflectance in estimating algal-chlorophyll concentration: A case study in a turbid reservoir
    Han, LH
    Rundquist, DC
    REMOTE SENSING OF ENVIRONMENT, 1997, 62 (03) : 253 - 261
  • [30] Measurement of particle-size distribution and concentration in heterogeneous turbid media with multispectral diffuse optical tomography
    Li, CQ
    Jiang, HB