Noninvasive measurement of fluorophore concentration in turbid media with a simple fluorescence/reflectance ratio technique

被引:53
作者
Weersink, R
Patterson, MS
Diamond, K
Silver, S
Padgett, N
机构
[1] Photon Res Ontario, Biophoton Facil, Toronto, ON M5G 2M9, Canada
[2] McMaster Univ, Hamilton, ON L8V 5C2, Canada
[3] Hamilton Reg Canc Ctr, Hamilton, ON L8V 5C2, Canada
关键词
D O I
10.1364/AO.40.006389
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Measurement of the concentration of fluorescent compounds in turbid media is difficult because the absorption and multiple scattering of excitation and emission of light has a large effect on the detected fluorescence. For surface measurements with optical fibers we demonstrate by experiments and numerical simulation that this effect can be minimized by measurement of the fluorescence at one source-detector distance, the diffusely reflected excitation light at a second distance, and with the ratio of these two signals as an indicator of fluorophore concentration. For optical properties typical of soft tissue in the red and the near infrared the optimum performance is obtained by measurement of fluorescence at 0.65 mm and reflectance at 1.35 mm. This choice reduces the rms error in fluorophore concentration to 14.6% over a wide range of absorption and scattering coefficients. (C) 2001 Optical Society of America.
引用
收藏
页码:6389 / 6395
页数:7
相关论文
共 20 条
[1]   A COMPARISON OF FLUORESCENCE METHODS USED IN THE PHARMACOKINETIC STUDIES OF ZN(II)PHTHALOCYANINE IN MICE [J].
BIOLO, R ;
JORI, G ;
KENNEDY, JC ;
NADEAU, P ;
POTTIER, R ;
REDDI, E ;
WEAGLE, G .
PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1991, 53 (01) :113-118
[2]   CLINICAL PHARMACOKINETIC STUDIES OF TETRA(META-HYDROXYPHENYL)CHLORIN IN SQUAMOUS-CELL CARCINOMA BY FLUORESCENCE SPECTROSCOPY AT 2 WAVELENGTHS [J].
BRAICHOTTE, D ;
SAVARY, JF ;
GLANZMANN, T ;
WESTERMANN, P ;
FOLLI, S ;
WAGNIERES, G ;
MONNIER, P ;
VANDENBERGH, H .
INTERNATIONAL JOURNAL OF CANCER, 1995, 63 (02) :198-204
[3]  
Braichotte DR, 1996, LASER SURG MED, V19, P340, DOI 10.1002/(SICI)1096-9101(1996)19:3<340::AID-LSM10>3.0.CO
[4]  
2-8
[5]   Monitoring photosensitizer concentration by use of a fiber-optic probe with a small source-detector separation [J].
Canpolat, M ;
Mourant, JR .
APPLIED OPTICS, 2000, 39 (34) :6508-6514
[6]  
DOIRON DR, 1995, P SOC PHOTO-OPT INS, V2396, P312, DOI 10.1117/12.208418
[7]   NONINVASIVE FLUORESCENCE DETECTION OF HEPATIC AND RENAL FUNCTION [J].
Dorshow, Richard B. ;
Bugaj, Joseph E. ;
Burleigh, B. Daniel ;
Duncan, James R. ;
Johnson, Michael A. ;
Jones, William B. .
JOURNAL OF BIOMEDICAL OPTICS, 1998, 3 (03) :340-345
[8]  
FRISOLI JK, 1993, CANCER RES, V53, P5954
[9]   Diffuse radiation in the galaxy [J].
Henyey, LG ;
Greenstein, JL .
ASTROPHYSICAL JOURNAL, 1941, 93 (01) :70-83
[10]   A diffusion theory model of spatially resolved fluorescence from depth-dependent fluorophore concentrations [J].
Hyde, DE ;
Farrell, TJ ;
Patterson, MS ;
Wilson, BC .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02) :369-383