Time is Money! Influence on Operating Theater and Sterilization Times of Patient-specific Cutting Guides and Single-use Instrumentation for Total Knee Arthroplasty: A Full Factorial Design of 136 Patients

被引:0
作者
Teissier, Victoria [1 ,3 ]
Biau, David [1 ]
Hamadouche, Moussa [1 ]
Talon, Damien [2 ]
Anract, Philippe [1 ]
机构
[1] Univ Paris, Hop Cochin, APHP, Dept Orthopaed Surg, Paris, France
[2] Cochin Teaching Hosp, Dept Pharm, Paris, France
[3] Cochin Teaching Hosp, 27 Rue Faubourg St Jacques, F-75014 Paris, France
来源
ARTHROPLASTY TODAY | 2022年 / 18卷
关键词
Arthroplasty; Single-use; Patient-specific; Efficiency; CONVENTIONAL INSTRUMENTATION; HIP; MULTICENTER; OUTCOMES; BENEFIT; BLOCKS; TKA;
D O I
10.1016/j.artd.2022.09.004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Patient-specific cutting guides (PSGs) and single-use disposable instrumentation (SUI) have emerged as potential beneficial innovations for total knee arthroplasty. The aim of this study was to evaluate the impact of PSG and SUI for total knee arthroplasty on operating room (OR) and sterilization times.Methods A monocentric, prospective, interventional, full factorial design study, including 136 patients, compared patient-specific (PSG, n = 68) to conventional cutting guides (n = 68) and SUI (n = 68) to conventional instrumentation (CVI, n = 68). In the OR, we recorded the number of instrument trays, operating time, and room occupancy time. In the central sterile services department, the total sterilization duration was assessed. The primary outcome was operating time and sterilization duration. Secondary outcomes were difference in the number of trays, Oxford Knee Score, and postoperative mechanical axis.Results The median operating time was 80 minutes (Q1-Q3: 73-90) and was significantly increased for SUI compared to that for CVI (+5 minutes, P = .0072). The median sterilization duration was 1261 minutes (Q1-Q3: 934-1603). It was significantly in favor of SUI (936 minutes) over CVI (1565 minutes) (+629 minutes, P < .0001). The total number of instrument trays was 404 for 136 patients: 252 for CVI and 152 for SUI (P < .0001) and 189 for PSG and 215 for conventional cutting guides (P = .0006). There was no significant difference in OKS (P = .86) nor in the postoperative alignment which was between 177 degrees and 183 degrees (75% patients, P = .24).Conclusions SUI lowers the number of instrument trays and sterilization duration. PSG is not associated with significant OR or sterilization time reduction. The use of SUI could reduce the risk of noncompliance of instrument trays.
引用
收藏
页码:95 / 102
页数:8
相关论文
共 27 条
  • [11] Logistical and Economic Advantages of Sterile-Packed, Single-Use Instruments for Total Knee Arthroplasty
    Goldberg, Tyler D.
    Maltry, John A.
    Ahuja, Mukesh
    Inzana, Jason A.
    [J]. JOURNAL OF ARTHROPLASTY, 2019, 34 (09) : 1876 - +
  • [12] Functional outcome and alignment in computer-assisted and conventionally operated total knee replacements
    Gothesen, O.
    Espehaug, B.
    Havelin, L. I.
    Petursson, G.
    Hallan, G.
    Strom, E.
    Dyrhovden, G.
    Furnes, O.
    [J]. BONE & JOINT JOURNAL, 2014, 96B (05) : 609 - 618
  • [13] Learning curve in navigated total knee replacement. A multi-centre study comparing experienced and beginner centres
    Jenny, Jean-Yves
    Miehlke, Rolf K.
    Giurea, Alexander
    [J]. KNEE, 2008, 15 (02) : 80 - 84
  • [14] Patient-Specific CT-Based Instrumentation versus Conventional Instrumentation in Total Knee Arthroplasty: A Prospective Randomized Controlled Study on Clinical Outcomes and In-Hospital Data
    Kotela, Andrzej
    Lorkowski, Jacek
    Kucharzewski, Marek
    Wilk-Franczuk, Magdalena
    Sliwinski, Zbigniew
    Franczuk, Boguslaw
    Legosz, Pawel
    Kotela, Ireneusz
    [J]. BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [15] Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030
    Kurtz, Steven
    Ong, Kevin
    Lau, Edmund
    Mowat, Fionna
    Halpern, Michael
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (04) : 780 - 785
  • [16] Single-Use Instrumentation, Cutting Blocks, and Trials Decrease Contamination during Total Knee Arthroplasty: A Prospective Comparison of Navigated and Nonnavigated Cases
    Mont, Michael A.
    Johnson, Aaron J.
    Issa, Kimona
    Pivec, Robert
    Blasser, Kurt E.
    McQueen, David
    Puri, Lalit
    Dethmers, Daniel A.
    Miller, David W.
    Ireland, Philip H.
    Shurman, John R.
    Bonutti, Petter
    [J]. JOURNAL OF KNEE SURGERY, 2013, 26 (04) : 285 - 290
  • [17] Assessment of mobility after multi-level surgery for cerebral palsy
    Graham, H. K.
    Harvey, A.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (08): : 993 - 994
  • [18] The cost-effectiveness of computer-assisted navigation in total knee arthroplasty
    Novak, Erik J.
    Silverstein, Marc D.
    Bozic, Kevin J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (11) : 2389 - 2397
  • [19] Are Patient-specific Cutting Blocks Cost-effective for Total Knee Arthroplasty?
    Nunley, Ryan M.
    Ellison, Bradley S.
    Ruh, Erin L.
    Williams, Brandon M.
    Foreman, Keith
    Ford, Adrienne D.
    Barrack, Robert L.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (03) : 889 - 894
  • [20] Is TKA Using Patient-specific Instruments Comparable to Conventional TKA? A Randomized Controlled Study of One System
    Roh, Yoon Whan
    Kim, Tae Woo
    Lee, Sahnghoon
    Seong, Sang Cheol
    Lee, Myung Chul
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (12) : 3988 - 3995