Correlating Tissue Response with Anatomical Location of mTBI Using a Human Head Finite Element Model under Simulated Blast Conditions

被引:0
|
作者
Harrigan, T. P. [1 ]
Roberts, J. C. [1 ]
Ward, E. E. [1 ]
Merkle, A. C. [1 ]
机构
[1] Johns Hopkins Univ, Appl Phys Lab, Laurel, MD USA
关键词
TBI; Head; Finite; Element; Model; TRAUMATIC BRAIN-INJURY; DISRUPTION;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Mild traumatic brain injury (mTBI) has recently been shown to include deficits in cognitive function that have been correlated to changes in tissue within regions of the white matter in the brain. These localized regions show decreased anisotropy in water diffusivity, which are thought to be related to local mechanical damage. However, a specific link to mechanical factors and tissue changes in these regions has not been made. This study is an initial attempt at such a correlation. A human head finite element model, verified against experimental data under simulated blast loading conditions, was used to estimate strains within regions in the brain that are correlated to functional deficits. Strain values from the most anterior and posterior extent of the corpus callosum (the rostrum and the splenium), the right and left anterior and posterior limb of the internal capsule (ALIC and PLIC), and the left cingulum bundle were calculated under frontal blast loading at overpressure intensities below those typically known to cause injury. Strain peaks of approximately 1 percent were noted in regions associated with cognitive brain injury, indicating that loading conditions which involve higher pressures could raise strains to significant levels.
引用
收藏
页码:18 / 21
页数:4
相关论文
共 50 条
  • [1] Pelvic Response of a Total Human Body Finite Element Model During Simulated Injurious Under Body Blast Impacts
    Weaver, Caitlin M.
    Guleyupoglu, Berkan
    Miller, Anna N.
    Kleinberger, Michael
    Stitzel, Joel D.
    ASCE-ASME JOURNAL OF RISK AND UNCERTAINTY IN ENGINEERING SYSTEMS PART B-MECHANICAL ENGINEERING, 2021, 7 (02):
  • [2] Evaluating thoracolumbar spine response during simulated underbody blast impact using a total human body finite element model
    Somasundaram, K.
    Zhang, L.
    Sherman, D.
    Begeman, P.
    Lyu, D.
    Cavanaugh, J. M.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 100
  • [3] Head and brain response to blast using sagittal and transverse finite element models
    Singh, Dilaver
    Cronin, Duane S.
    Haladuick, Tyler N.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2014, 30 (04) : 470 - 489
  • [4] A COMPARATIVE STUDY OF THE HUMAN BODY FINITE ELEMENT MODEL UNDER BLAST LOADINGS
    Tan, X. G.
    Kannan, R.
    Przekwas, Andrzej J.
    INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 2: BIOMEDICAL AND BIOTECHNOLOGY, 2013, : 829 - 836
  • [5] Brain response to primary blast wave using validated finite element models of human head and advanced combat helmet
    Zhang, Liying
    Makwana, Rahul
    Sharma, Sumit
    FRONTIERS IN NEUROLOGY, 2013, 4
  • [6] Study on the influence of different interface conditions on the response of finite element human head models under occipital impact loading
    Aomura, S
    Fujiwara, S
    Ikoma, T
    JSME INTERNATIONAL JOURNAL SERIES C-MECHANICAL SYSTEMS MACHINE ELEMENTS AND MANUFACTURING, 2003, 46 (02) : 583 - 593
  • [7] RESPONSE OF POST-MORTEM HUMAN HEAD UNDER PRIMARY BLAST LOADING CONDITIONS-EFFECT OF BLAST OVERPRESSURES
    Ganpule, Shailesh
    Salzar, Robert
    Chandra, Namas
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 3A, 2014,
  • [8] Assessment of structural response of an existing structure under blast load using finite element analysis
    Ibrahim, Yasser E.
    Nabil, Marwa
    ALEXANDRIA ENGINEERING JOURNAL, 2019, 58 (04) : 1327 - 1338
  • [9] Regional Strain Response of an Anatomically Accurate Human Finite Element Head Model Under Frontal Versus Lateral Loading
    Rooks, Tyler F.
    Chancey, Valeta Carol
    Baisden, Jamie L.
    Yoganandan, Narayan
    MILITARY MEDICINE, 2023, 188 : 420 - 427
  • [10] Characteristics of Bone-Conduction Devices Simulated in a Finite-Element Model of a Whole Human Head
    Chang, You
    Stenfelt, Stefan
    TRENDS IN HEARING, 2019, 23