Stopped-flow Light Scattering Analysis of Red Blood Cell Glycerol Permeability

被引:1
|
作者
Gena, Patrizia [1 ]
Portincasa, Piero [2 ]
Matera, Sabino [1 ]
Sonntag, Yonathan [3 ]
Rutzler, Michael [3 ,4 ]
Calamita, Giuseppe [1 ]
机构
[1] Univ Bari Aldo Moro, Dept Biosci Biotechnol & Biopharmaceut, Bari, Italy
[2] Univ Bari Aldo Moro, Med Sch, Dept Biomed Sci & Human Oncol, Clin Med A Murri, Bari, Italy
[3] Lund Univ, Dept Biochem & Struct Biol, Lund, Sweden
[4] ApoGlyx AB, Malmo, Sweden
来源
BIO-PROTOCOL | 2020年 / 10卷 / 16期
关键词
Stopped-flow light scattering; Erythrocytes; Glycerol membrane permeability; Aquaglyceroporins; Aquaporin inhibitors; OSMOTIC WATER PERMEABILITY; MICE LACKING AQUAPORIN-1; TRANSPORT; MEMBRANE; CHANNEL; PROTEIN; RECONSTITUTION; EXPRESSION; ENDOSOMES;
D O I
10.21769/BioProtoc.3723
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Stopped-Flow Light Scattering (SFLS) is a method devised to analyze the kinetics of fast chemical reactions that result in a significant change of the average molecular weight and/or in the shape of the reaction substrates. Several modifications of the original stopped-flow system have been made leading to a significant extension of its technical applications. One of these modifications allows the biophysical characterization of the water and solute permeability of biological and artificial membranes. Here, we describe a protocol of SFLS to measure the glycerol permeability of isolated human red blood cells (RBCs) and evaluate the pharmacokinetics properties (selectivity and potency) of isoform-specific inhibitors of AQP3, AQP7 and AQP9, three mammalian aquaglyceroporins allowing transport of glycerol across membranes. Suspensions of RBCs (1% hematocrit) are exposed to an inwardly directed gradient of 100 mM glycerol in a SFLS apparatus at 20 degrees C and the resulting changes in scattered light intensity are recorded at a monochromatic wavelength of 530 nm for 120 s. The SFLS apparatus is set up to have a dead time of 1.6-ms and 99% mixing efficiency in less than 1 ms. Data are fitted to a single exponential function and the related time constant (tau, seconds) of the cell-swelling phase of light scattering corresponding to the osmotic movement of water that accompanies the entry of glycerol into erythrocytes is measured. The coefficient of glycerol permeability (P-gly, cm/s) of RBCs is calculated with the following equation: P-gly = 1/[(S/V)tau] where tau (s) is the fitted exponential time constant and S/V is the surface-to-volume ratio (cm(-1)) of the analyzed RBC specimen. Pharmacokinetics of the isoform-specific inhibitors of AQP3, AQP7 and AQP9 are assessed by evaluating the extent of RBC P-gly values resulting after the exposure to serial concentrations of the blockers.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Numerical analysis of oxygen uptake processes by red blood cells in stopped-flow measurements: Effects of cell shape, membrane permeability and unstirred layer
    Amiri, Farhad A.
    Zhang, Junfeng
    MEDICAL ENGINEERING & PHYSICS, 2023, 121
  • [2] KINETIC AND MECHANISTIC ANALYSIS OF PROTHROMBIN-MEMBRANE BINDING BY STOPPED-FLOW LIGHT-SCATTERING
    WEI, GJ
    BLOOMFIELD, VA
    RESNICK, RM
    NELSESTUEN, GL
    BIOCHEMISTRY, 1982, 21 (08) : 1949 - 1959
  • [3] Ribosome formation from subunits studied by stopped-flow and Rayleigh light scattering
    Antoun A.
    Pavlov M.Y.
    Tenson T.
    Ehrenberg M.
    Biological Procedures Online, 2004, 6 (1) : 35 - 54
  • [4] STUDIES OF THE DIFFUSION BOUNDARY-LAYER AROUND THE RED BLOOD-CELL IN A STOPPED-FLOW APPARATUS
    WILLIAMS, JB
    KUTCHAI, H
    BIOPHYSICAL JOURNAL, 1985, 47 (02) : A160 - A160
  • [5] Stopped-flow dynamic light scattering as a method to monitor compaction during protein folding
    K. Gast
    Angela Nöppert
    Marlies Müller-Frohne
    Dietrich Zirwer
    Gregor Damaschun
    European Biophysics Journal, 1997, 25 : 211 - 219
  • [6] STOPPED-FLOW APPARATUS WITH LIGHT-SCATTERING DETECTION AND ITS APPLICATION TO BIOCHEMICAL REACTIONS
    RIESNER, D
    BUENEMAN.H
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1973, 70 (03) : 890 - 893
  • [7] FLUORESCENCE STOPPED-FLOW AND TEMPERATURE-JUMP STUDIES OF ANION TRANSPORT IN THE RED-BLOOD-CELL MEMBRANE
    DIX, JA
    VERKMAN, AS
    CANTLEY, LC
    SOLOMON, AK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1980, 179 (MAR): : 23 - COLL
  • [8] AN APPARATUS FOR STOPPED-FLOW X-RAY-SCATTERING
    BERTHETCOLOMINAS, C
    BOIS, JM
    CUILLEL, M
    SEDITA, J
    VACHETTE, P
    REVUE DE PHYSIQUE APPLIQUEE, 1984, 19 (09): : 769 - 772
  • [9] Stopped-flow, classical, and dynamic light scattering analysis of matrix protein binding to nucleocapsids of vesicular stomatitis virus
    Lyles, DS
    McKenzie, MO
    Hantgan, RR
    BIOCHEMISTRY, 1996, 35 (20) : 6508 - 6518
  • [10] SCATTERING OF LIGHT BY A RED BLOOD CELL
    Borovoi, A. G.
    Naats, E. I.
    Oppel, U. G.
    JOURNAL OF BIOMEDICAL OPTICS, 1998, 3 (03) : 364 - 372