A grating-based optical readout method for microcantilever biosensor

被引:2
|
作者
Wen, Feng [1 ,3 ]
Zhao, Yuejin [1 ]
Yu, Xiaomei [2 ]
Gong, Cheng [1 ]
Yang, Jiancheng [2 ]
机构
[1] Beijing Inst Technol, Sch Optoelect, Beijing 100081, Peoples R China
[2] Peking Univ, Inst Microelect, Natl Key Lab Sci & Technol Micro Nano Fabricat, Beijing 100871, Peoples R China
[3] North Univ China, Natl Key Lab Elect Measurement Technol, Taiyuan 030051, Peoples R China
来源
OPTIK | 2014年 / 125卷 / 01期
关键词
Reflecting grating; Microcantilever; Diffraction; Feedback balancing; CCD; SENSOR;
D O I
10.1016/j.ijleo.2013.06.031
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
For measuring the deflections of the microcantilever biosensor, a reflective grating microcantilevers based on SDI were designed and fabricated, a high precision optical readout approach based on diffraction spectrum balancing feedback control was presented. The diffraction spectrum image was collected by a 12-bit digital area array monochrome CCD. According to the sum gray value of the image which subtracted each other at the balancing position and bending position to control a high precision motorized rotation stage revolve make the sum gray value remained in the balancing position always, then the motorized rotation stage revolving angle is just the cantilever bend angle. The resolution of motorized rotation stage is 35 x 10(-6) deg, the system practical measurement resolution is 1 x 10(-4) deg, that is to say, for a length of 250 mu m microcantilever, the tip measure resolution is up to 0.043 nm. Measurement results clearly demonstrate that this reflective grating microcantilever biosensor and this read out method have a great potential for biological and chemical applications. (C) 2013 Elsevier GmbH. All rights reserved.
引用
收藏
页码:84 / 88
页数:5
相关论文
共 50 条
  • [1] A GRATING-BASED PLASMON BIOSENSOR WITH HIGH RESOLUTION
    Luo, Z.
    Suyama, T.
    Xu, X.
    Okuno, Y.
    PROGRESS IN ELECTROMAGNETICS RESEARCH-PIER, 2011, 118 : 527 - 539
  • [2] GRATING-BASED ACCELERATION SENSORS WITH OPTICAL INTERFEROMETRIC READOUT AND CLOSED-LOOP CONTROL
    Williams, Randall P.
    Hall, Neal A.
    Avenson, Brad D.
    2019 20TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS & EUROSENSORS XXXIII (TRANSDUCERS & EUROSENSORS XXXIII), 2019, : 507 - 510
  • [3] A grating microcantilever biosensor based on diffraction spectrum feedback balanced
    Wen, Feng
    Zhao, Yuejin
    Yu, Xiaomei
    NANO-BIO SENSING, IMAGING, AND SPECTROSCOPY, 2013, 8879
  • [4] Optical readout method based on a narrow-strip filter for microcantilever array sensing
    Gong, Cheng
    Hui, Mei
    Dong, Liquan
    Zhao, Yuejin
    Yu, Xiaomei
    Liu, Xiaohua
    OPTICS LETTERS, 2012, 37 (07) : 1187 - 1189
  • [5] Fabrication techniques for grating-based optical devices
    Lim, MH
    Murphy, TE
    Ferrera, J
    Damask, JN
    Smith, HI
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1999, 17 (06): : 3208 - 3211
  • [6] Grating-based optical fiber corrosion sensors
    Greene, JA
    Jones, ME
    Duncan, PG
    Kozikowski, CL
    Bailey, TA
    May, RG
    Murphy, KA
    SMART SENSING, PROCESSING, AND INSTRUMENTATION - SMART STRUCTURES AND MATERIALS 1997, 1997, 3042 : 260 - 266
  • [7] Study on a Plasmonic Tilted Fiber Grating-Based Biosensor for Calmodulin Detection
    Chen, Xiaoyong
    Jiang, Jie
    Zhang, Nan
    Lin, Wenwei
    Xu, Pin
    Sun, Jinghua
    BIOSENSORS-BASEL, 2021, 11 (06):
  • [8] Optical readout method for microcantilever array sensing and its sensitivity analysis
    Miao, Zhengyu
    Zhang, Qingchuan
    Guo, Zheying
    Wu, Xiaoping
    Chen, Dapeng
    OPTICS LETTERS, 2007, 32 (06) : 594 - 596
  • [9] Accurate characterization of Bragg grating-based optical devices
    Rahman, BMA
    Plura, M
    Gomoluch, JM
    Grattan, KTV
    FIBER OPTIC SENSOR TECHNOLOGY AND APPLICATIONS, 1999, 3860 : 77 - 88
  • [10] Optical fiber random grating-based multiparameter sensor
    Xu, Yanping
    Lu, Ping
    Gao, Song
    Xiang, Dao
    Lu, Ping
    Mihailov, Stephen
    Bao, Xiaoyi
    OPTICS LETTERS, 2015, 40 (23) : 5514 - 5517