Effect of the interface condition on the bond between flax FRP tube and coconut fibre reinforced concrete composites

被引:14
|
作者
Chen, Jiaxin [1 ]
Chouw, Nawawi [1 ]
机构
[1] Univ Auckland, Dept Civil & Environm Engn, Auckland Mail Ctr,Private Bag 92019, Auckland 1142, New Zealand
关键词
Natural fibre reinforced composite; Flax FRP tube confinement; Various surface conditions; Interface bond; Pust-out test; TUBULAR CFDST MEMBERS; PUSH-OUT TESTS; SEISMIC BEHAVIOR; NATURAL FIBERS; HIGH-STRENGTH; STEEL BEAMS; SHEAR; CONNECTIONS; COLUMNS; IMPACT;
D O I
10.1016/j.conbuildmat.2018.01.152
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper addresses an experimental study on the bond of flax fibre reinforced polymer confined coconut fibre reinforced concrete composite. Four different conditions of the interface between the flax fibre reinforced polymer and coconut fibre reinforced concrete were considered. Twelve cylindrical specimens were fabricated and push-out tests were performed. Test results show that the mechanically bonded interface highly enhanced the bond between the polymer and concrete core. In addition, an equation was developed based on the experimental data to estimate the slippage resistance provided by the mechanically interface. The failure modes of all type of specimens will also be discussed. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:597 / 604
页数:8
相关论文
共 13 条
  • [1] Behavior and analytical modeling of natural flax fibre-reinforced polymer tube confined plain concrete and coir fibre-reinforced concrete
    Yan, Libo
    Chouw, Nawawi
    JOURNAL OF COMPOSITE MATERIALS, 2013, 47 (17) : 2133 - 2148
  • [2] Interface properties and their effect on the mechanical performance of flax fibre thermoplastic composites
    Woigk, W.
    Fuentes, C. A.
    Rion, J.
    Hegemann, D.
    van Vuure, A. W.
    Dransfeld, C.
    Masania, K.
    COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2019, 122 : 8 - 17
  • [3] Bond between TRM versus FRP composites and concrete at high temperatures
    Raoof, Saad M.
    Bournas, Dionysios A.
    COMPOSITES PART B-ENGINEERING, 2017, 127 : 150 - 165
  • [4] INTERFACE BOND BEHAVIOUR BETWEEN CIRCULAR STEEL TUBE AND LIGHTWEIGHT AGGREGATE CONCRETE
    Fu, Z. Q.
    Ge, H. B.
    Ji, B. H.
    Chen, J. J.
    ADVANCED STEEL CONSTRUCTION, 2018, 14 (03): : 424 - 437
  • [5] Bond between FRP composites and concrete: Assessment of design procedures and analytical models
    D'Antino, Tommaso
    Pellegrino, Carlo
    COMPOSITES PART B-ENGINEERING, 2014, 60 : 440 - 456
  • [6] Interface Bond Improvement of Sisal Fibre Reinforced Polylactide Composites with Added Epoxy Oligomer
    Hao, Mingyang
    Wu, Hongwu
    Qiu, Feng
    Wang, Xiwen
    MATERIALS, 2018, 11 (03)
  • [7] Effect of graphene oxide fibre surface modification on low-velocity impact and fatigue performance of flax fibre reinforced composites
    Javanshour, F.
    Prapavesis, A.
    Lahtonen, K.
    Pournoori, N.
    Parnanen, T.
    Kanerva, M.
    Van Vuure, A. W.
    Sarlin, E.
    COMPOSITES PART C: OPEN ACCESS, 2023, 11
  • [8] Bond performance between FRP tubes and seawater sea sand concrete after exposure to seawater condition
    Bazli, Milad
    Zhao, Xiao-Ling
    Raman, R. K. Singh
    Bai, Yu
    Al-Saadi, Saad
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 265
  • [9] Interface bond between FRP sheets and concrete substrates: properties, numerical modeling and roles in member behaviour
    Ueda, T
    Dai, JG
    PROGRESS IN STRUCTURAL ENGINEERING AND MATERIALS, 2005, 7 (01) : 27 - 43
  • [10] The bond behavior of the interface between high-strength concrete-filled double-skin steel tube
    Liu, Xiao
    Huang, Dongdong
    Hou, Xinyu
    Yu, Shuming
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 226