Individual A-Scan Signal Normalization Between Two Spectral Domain Optical Coherence Tomography Devices

被引:11
作者
Chen, Chieh-Li [1 ,2 ]
Ishikawa, Hiroshi [1 ,2 ]
Wollstein, Gadi [1 ]
Ling, Yun [3 ]
Bilonick, Richard A. [1 ,3 ]
Kagemann, Larry [1 ,2 ]
Sigal, Ian A. [1 ,2 ,4 ]
Schuman, Joel S. [1 ,2 ,4 ]
机构
[1] Univ Pittsburgh, Sch Med, Dept Ophthalmol, UPMC Eye Ctr,Eye & Ear Inst,Ophthalmol & Visual S, Pittsburgh, PA 15261 USA
[2] Univ Pittsburgh, Dept Bioengn, Swanson Sch Engn, Pittsburgh, PA 15261 USA
[3] Univ Pittsburgh, Grad Sch Publ Hlth, Dept Biostat, Pittsburgh, PA 15261 USA
[4] Univ Pittsburgh, Sch Med, McGowan Inst Regenerat Sci, Pittsburgh, PA 15261 USA
基金
美国国家卫生研究院;
关键词
optical coherence tomography; image analysis; comparability; NERVE-FIBER LAYER; ATTENUATION COEFFICIENT; QUANTITATIVE-ANALYSIS; TIME-DOMAIN; THICKNESS; OCT; INSTRUMENTS; AGREEMENT; GLAUCOMA; IMAGES;
D O I
10.1167/iovs.12-11484
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. We developed a method to normalize optical coherence tomography (OCT) signal profiles from two spectral-domain (SD) OCT devices so that the comparability between devices increases. METHODS. We scanned 21 eyes from 14 healthy and 7 glaucoma subjects with two SD-OCT devices on the same day, with equivalent cube scan patterns centered on the fovea (Cirrus HD-OCT and RTVue). Foveola positions were selected manually and used as the center for registration of the corresponding images. A-scan signals were sampled 1.8 mm from the foveola in the temporal, superior, nasal, and inferior quadrants. After oversampling and rescaling RTVue data along the Z-axis to match the corresponding Cirrus data format, speckle noise reduction and amplitude normalization were applied. For comparison between normalized A-scan profiles, mean absolute difference in amplitude in percentage was measured at each sampling point. As a reference, the mean absolute difference between two Cirrus scans on the same eye also was measured. RESULTS. The mean residual of the A-scan profile amplitude was reduced significantly after signal normalization (12.7% vs. 6.2%, P < 0.0001, paired t-test). All four quadrants also showed statistically significant reduction (all P < 0.0001). Mean absolute difference after normalization was smaller than the one between two Cirrus scans. No performance difference was detected between health and glaucomatous eyes. CONCLUSIONS. The reported signal normalization method successfully reduced the A-scan profile differences between two SD-OCT devices. This signal normalization processing may improve the direct comparability of OCT image analysis and measurement on various devices.
引用
收藏
页码:3463 / 3471
页数:9
相关论文
共 23 条
[1]   Comparison of Retinal Nerve Fiber Layer Thickness Measurement Bias and Imprecision across Three Spectral-Domain Optical Coherence Tomography Devices [J].
Buchser, Nancy M. ;
Wollstein, Gadi ;
Ishikawa, Hiroshi ;
Bilonick, Richard A. ;
Ling, Yun ;
Folio, Lindsey S. ;
Kagemann, Larry ;
Noecker, Robert J. ;
Albeiruti, Eiyass ;
Schuman, Joel S. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (07) :3742-3747
[2]   Special Requirements for Electronic Health Record Systems in Ophthalmology [J].
Chiang, Michael F. ;
Boland, Michael V. ;
Brewer, Allen ;
Epley, K. David ;
Horton, Mark B. ;
Lim, Michele C. ;
McCannel, Colin A. ;
Patel, Sayjal J. ;
Silverstone, David E. ;
Wedemeyer, Linda ;
Lum, Flora .
OPHTHALMOLOGY, 2011, 118 (08) :1681-1687
[3]  
DICOM Standards Committee, PROP COLL DICOM INT
[4]   State-of-the-art retinal optical coherence tomography [J].
Drexler, Wolfgang ;
Fujimoto, James G. .
PROGRESS IN RETINAL AND EYE RESEARCH, 2008, 27 (01) :45-88
[5]   Automated retinal shadow compensation of optical coherence tomography images [J].
Fabritius, Tapio ;
Makita, Shuichi ;
Hong, Yongjoo ;
Myllyla, Risto ;
Yasuno, Yoshiaki .
JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (01)
[6]   Optical Coherence Tomography: History, Current Status, and Laboratory Work [J].
Gabriele, Michelle L. ;
Wollstein, Gadi ;
Ishikawa, Hiroshi ;
Kagemann, Larry ;
Xu, Juan ;
Folio, Lindsey S. ;
Schuman, Joel S. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (05) :2425-2436
[7]   Three dimensional optical coherence tomography imaging: Advantages and advances [J].
Gabriele, Michelle L. ;
Wollstein, Gadi ;
Ishikawa, Hiroshi ;
Xu, Juan ;
Kim, Jongsick ;
Kagemann, Larry ;
Folio, Lindsey S. ;
Schuman, Joel S. .
PROGRESS IN RETINAL AND EYE RESEARCH, 2010, 29 (06) :556-579
[8]   Shadow Removal and Contrast Enhancement in Optical Coherence Tomography Images of the Human Optic Nerve Head [J].
Girard, Michael J. A. ;
Strouthidis, Nicholas G. ;
Ethier, C. Ross ;
Mari, Jean Martial .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (10) :7738-7748
[9]   OPTICAL COHERENCE TOMOGRAPHY OF THE HUMAN RETINA [J].
HEE, MR ;
IZATT, JA ;
SWANSON, EA ;
HUANG, D ;
SCHUMAN, JS ;
LIN, CP ;
PULIAFITO, CA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (03) :325-332
[10]  
Huang Y, 2013, INVEST OPHTH VIS SCI, V53, P2133