Silver surface enrichment in ancient coins studied by micro-PIXE

被引:30
作者
Ager, F. J. [1 ,2 ]
Moreno-Suarez, A. I. [1 ,2 ]
Scrivano, S. [1 ]
Ortega-Feliu, I. [1 ]
Gomez-Tubio, B. [1 ,3 ]
Respaldiza, M. A. [1 ,4 ]
机构
[1] Univ Seville, CSIC J Andalucia, Ctr Nacl Aceleradores, C Thomas Alva Edison 7, Seville 41092, Spain
[2] Univ Seville, Dept Fis Aplicada 1, Seville 41092, Spain
[3] Univ Seville, Dept Fis Aplicada 3, Seville 41092, Spain
[4] Univ Seville, Dept Fis Atom Mol & Nucl, Seville 41092, Spain
关键词
PIXE; Nuclear microprobe; Roman silver coins; Silver enrichment; Silver-copper alloys; XRF;
D O I
10.1016/j.nimb.2012.12.037
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The surface enrichment of archeological silver-copper alloys, either intentional or due to corrosion processes, has been known for many years. The most used non-destructive techniques, such as particle-induced X-ray emission (PIXE) and X-ray fluorescence (XRF) are surface techniques, with penetration depths typically ranging from a few microns to a few tens of microns. Therefore, these techniques could produce results which are not representative of the bulk composition of the alloy. In order to gain insight into the silver enrichment process and the effects on the data obtained with these techniques, a set of silver roman denarii were cross sectioned and analyzed at the Centro Nacional de Aceleradores micro-PIXE facility. Elemental maps show silver surface enriched layers up to 250 mu m thick. Besides, silver-enriched surface layers are not found for alloys with 96-98 wt.% Ag. (C)12 Elsevier B.V. All rights reserved.
引用
收藏
页码:241 / 244
页数:4
相关论文
共 17 条
[1]  
Ager F. J., 2009, NUCL INSTRUM METH B, P429
[2]  
[Anonymous], WINQXAS QUANT XRAY A
[3]   Silver surface enrichment controlled by simultaneous RBS for reliable PIXE analysis of ancient coins [J].
Beck, L. ;
Alloin, E. ;
Berthier, C. ;
Reveillon, S. ;
Costa, V. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (10) :2320-2324
[4]   Silver surface enrichment of silver-copper alloys:: a limitation for the analysis of ancient silver coins by surface techniques [J].
Beck, L ;
Bosonnet, S ;
Réveillon, S ;
Eliot, D ;
Pilon, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 226 (1-2) :153-162
[5]   A modular system for XRF and XRD applications consisting of a microfocus X-ray source and different capillary optics [J].
Bjeoumikhov, A ;
Langhoff, N ;
Rabe, J ;
Wedell, R .
X-RAY SPECTROMETRY, 2004, 33 (04) :312-316
[6]   The Guelph PIXE software package IV [J].
Campbell, J. L. ;
Boyd, N. I. ;
Grassi, N. ;
Bonnick, P. ;
Maxwell, J. A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (20) :3356-3363
[7]  
Cope L.H ., 1972, METHODS CHEM M ETALL, P261
[8]  
Crawford M.H., 1982, ROMAN REPUBLICAN COI
[9]   CNA:: The first accelerator-based IBA facility in Spain [J].
García-López, J ;
Ager, FJ ;
Rank, MB ;
Madrigal, FJ ;
Ontalba, MA ;
Respaldiza, MA ;
Ynsa, MD .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 161 :1137-1142
[10]   X-ray Fluorescence analytical criteria to assess the fineness of ancient silver coins: Application on Ptolemaic coinage [J].
Kantarelou, Vasiliki ;
Ager, Francisco Jose ;
Eugenidou, Despoina ;
Chaves, Francisca ;
Andreou, Alexandros ;
Kontou, Elena ;
Katsikosta, Niki ;
Respaldiza, Miguel Angel ;
Serafin, Patrizia ;
Sokaras, Dimosthenis ;
Zarkadas, Charalambos ;
Polikreti, Kyriaki ;
Karydas, Andreas Germanos .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (9-10) :681-690