Characterization of the Mechanism and Substrate of Atrial Tachycardia Using Ultra-High-Density Mapping in Adults With Congenital Heart Disease: Impact on Clinical Outcomes

被引:19
|
作者
Mantziari, Lilian [1 ]
Butcher, Charles [1 ]
Shi, Rui [1 ]
Kontogeorgis, Andrianos [1 ]
Opel, Aaisha [1 ]
Chen, Zhong [1 ]
Haldar, Shouvik [1 ]
Panikker, Sandeep [1 ]
Hussain, Wajid [1 ]
Jones, David Gareth [1 ]
Gatzoulis, Michael A. [1 ]
Markides, Vias [1 ]
Ernst, Sabine [1 ]
Wong, Tom [1 ]
机构
[1] Royal Brompton & Harefield NHS Fdn Trust, London, England
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2019年 / 8卷 / 04期
关键词
ablation; atrial tachycardia; congenital heart disease; electrophysiology mapping; high density mapping; substrate mapping; ABLATION; ARRHYTHMIAS; MANAGEMENT; SYSTEM;
D O I
10.1161/JAHA.118.010535
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Atrial tachycardia (AT) is common in patients with adult congenital heart disease and is challenging to map and ablate. We used ultra-high-density mapping to characterize the AT mechanism and investigate whether substrate characteristics are related to ablation outcomes. Methods and Results-A total of 50 ATs were mapped with ultra-high-density mapping in 23 procedures. Patients were followed up for up to 12 months. Procedures were classified to group A if there was 1 single AT induced (n=12) and group B if there were >= 2 ATs induced (n=11 procedures). AT mechanism per procedure was macro re-entry (n=10) and localized re-entry (n=2) in group A and multiple focal (n=6) or multiple macro re-entry (n=5) in group B. Procedure duration, low voltage area (0.05-0.5 mV), and low voltage area indexed for volume were higher in group B (159 [147-180] versus 412 [352-420] minutes, P<0.001, 22.6 [12.2-29.8] versus 54.2 [51.1-61.6] cm(2), P=0.014 and 0.17 [0.12-0.21] versus 0.26 [0.23-0.27] cm(2)/mL, P=0.024 accordingly). Dense scar (<0.05 mV) and atrial volume were similar between groups. Acute success and freedom from arrhythmia recurrence were worse in group B (100% versus 77% P=0.009 and 11.3, CI 9.8-12.7 versus 4.9, CI 2.2-7.6 months, log rank P=0.004). Indexed low voltage area >= 0.24 cm(2)/mL could predict recurrence with 100% sensitivity and 77% specificity (area under the curve 0.923, P=0.007). Conclusions-Larger low voltage area but not dense scar is associated with the induction of multiple focal or re-entry ATs, which are subsequently associated with longer procedure duration and worse acute and midterm clinical outcomes.
引用
收藏
页数:17
相关论文
共 23 条
  • [21] Outcome of ventricular tachycardia catheter ablation in ischemic heart disease patients using a high-density mapping substrate-based approach: A prospective cohort study
    da Silva, Gustavo Lima
    Cortez-Dias, Nuno
    Carpinteiro, Luis
    Pinto, Fausto J.
    de Sousa, Joao
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2022, 41 (04) : 325 - 335
  • [22] Impact of a high-density grid catheter on long-term outcomes for structural heart disease ventricular tachycardia ablation
    Proietti, Riccardo
    Dowd, Rory
    Gee, Lim Ven
    Yusuf, Shamil
    Panikker, Sandeep
    Hayat, Sajad
    Osman, Faizel
    Patel, Kiran
    Salim, Handi
    Aldhoon, Bashar
    Foster, Will
    Merghani, Ahmed
    Kuehl, Michael
    Banerjee, Prithwish
    Lellouche, Nicolas
    Dhanjal, Tarvinder
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 62 (03) : 519 - 529
  • [23] Impact of a high-density grid catheter on long-term outcomes for structural heart disease ventricular tachycardia ablation
    Riccardo Proietti
    Rory Dowd
    Lim Ven Gee
    Shamil Yusuf
    Sandeep Panikker
    Sajad Hayat
    Faizel Osman
    Kiran Patel
    Handi Salim
    Bashar Aldhoon
    Will Foster
    Ahmed Merghani
    Michael Kuehl
    Prithwish Banerjee
    Nicolas Lellouche
    Tarvinder Dhanjal
    Journal of Interventional Cardiac Electrophysiology, 2021, 62 : 519 - 529