Amperometric detection of salivary α-amylase on screen-printed carbon electrodes as a simple and inexpensive alternative for point-of-care testing

被引:41
作者
Garcia, Paulo T. [1 ]
Guimaraes, Luiza N. [1 ]
Dias, Anderson A. [1 ]
Ulhoa, Cirano J. [2 ]
Coltro, Wendell K. T. [1 ,3 ]
机构
[1] Univ Fed Goias, Inst Quim, Campus Samambaia, BR-74690900 Goiania, Go, Brazil
[2] Univ Fed Goias, Inst Ciencias Biol, BR-74690900 Goiania, Go, Brazil
[3] Inst Nacl Ciencia & Tecnol Bioanalit, BR-13083970 Campinas, SP, Brazil
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2018年 / 258卷
关键词
Biomarker; Electrochemical detection; Clinical diagnosis; Maltose; Point-of-carea; MICROFLUIDIC DEVICES; STRESS; URINE; PERFORMANCE; BIOSENSOR; GLUCOSE; IMMUNOSENSOR; IMMUNOASSAY; VALIDATION; COMPLEXES;
D O I
10.1016/j.snb.2017.11.068
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study describes the amperometric detection of salivary alpha-amylase (sAA) in human saliva samples using screen-printed carbon electrodes (SPCE). The proposed method was based on the indirect determination of sAA in a sequence of two chemical reactions. Basically, the first reaction is the hydrolysis of starch by sAA to produce maltose. Then, the generated reducing sugar promotes the conversion of [Fe(CN)(6)](3-) into [Fe(CN)(6)](4-) in a second reaction. Different parameters, such as pH, reaction time, sAA volume and starch concentration were thoroughly optimised. The best electrochemical response was found using 5 mmol L-1 NaOH (pH = 12), reaction time of 20 min, sAA volume of 15 mu L and 0.5% (w/v) starch. The analytical performance revealed good linear correlation for sAA concentration levels between 100 and 1200 U mL(-1). The achieved limit of detection (LOD) and sensitivity values were 1.1 U mL(-1) and 10.7 mu A/(log U mL(-1)), respectively. The proposed electrochemical sensor exhibited great selectivity. The amperometric response for sAA was recorded in the presence of different glucose levels( 0.01-0.10 mmol L-1) and no noticeable change was observed. The feasibility of the proposed method was investigated through the determination of sAA levels in five human saliva samples. The concentration levels found ranged between 182.8 and 1117.1 U mL(-1) and presented accuracy between 90 and 97%. The method reported herein emerges as a simple, inexpensive, portable, reliable and powerful tool for rapid point-of-care testing (POCT). (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:342 / 348
页数:7
相关论文
共 61 条
  • [1] Hypertriglyceridemic Pancreatitis Caused by the Oral Contraceptive Agent Estrostep
    Abraham, Mary
    Mitchell, Jennifer
    Simsovits, Debra
    Gasperino, James
    [J]. JOURNAL OF INTENSIVE CARE MEDICINE, 2015, 30 (05) : 303 - 307
  • [2] Voltammetric Lead Determination in Aviation Fuel Samples Using a Screen-Printed Gold Electrode and Batch-Injection Analysis
    Almeida, Eduardo S.
    Richter, Eduardo M.
    Munoz, Rodrigo A. A.
    [J]. ELECTROANALYSIS, 2016, 28 (03) : 633 - 639
  • [3] Salivary alpha-amylase response to acute psychosocial stress: The impact of age
    Almela, Mercedes
    Hidalgo, Vanesa
    Villada, Carolina
    van der Meij, Leander
    Espin, Laura
    Gomez-Amor, Jesus
    Salvador, Alicia
    [J]. BIOLOGICAL PSYCHOLOGY, 2011, 87 (03) : 421 - 429
  • [4] [Anonymous], ANALYST
  • [5] [Anonymous], RSC ADV
  • [6] [Anonymous], CHINESE J ANAL CHEM
  • [7] [Anonymous], 2016, CURR DIABETES REP, DOI DOI 10.1007/S11892-016-0794-7
  • [8] [Anonymous], 2015, CRITICAL REV FOOD SC, DOI DOI 10.1016/J.CARBPOL.2011.01.002
  • [9] Clinical applications of amylase: Novel perspectives
    Azzopardi, Ernest
    Lloyd, Catherine
    Teixeira, Sofia Rodrigues
    Conlan, R. Steven
    Whitaker, Iain S.
    [J]. SURGERY, 2016, 160 (01) : 26 - 37
  • [10] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF ALPHA-AMYLASES FROM GERMINATING WHEAT AND COMPLEXES WITH THE ALPHA-AMYLASE INHIBITOR FROM BARLEY
    BATTERSHELL, VG
    HENRY, RJ
    [J]. JOURNAL OF CEREAL SCIENCE, 1990, 12 (01) : 73 - 81