Cardiac Output Monitoring by Pulse Contour Analysis, the Technical Basics of Less-Invasive Techniques

被引:38
作者
Grensemann, Joern [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Intens Care Med, Ctr Anesthesiol & Intens Care Med, Hamburg, Germany
关键词
hemodynamics; cardiac output; monitoring; physiologic; pulse contour analyses; waveform analysis; arterial wave property; RECORDING ANALYTICAL METHOD; PULMONARY-ARTERY CATHETER; TRANSPULMONARY THERMODILUTION; FLOTRAC/VIGILEO SYSTEM; DYNAMIC-RESPONSE; TRACK CHANGES; FAST FLUSH; PRESSURE; VALIDATION; THERAPY;
D O I
10.3389/fmed.2018.00064
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Routine use of cardiac output (CO) monitoring became available with the introduction of the pulmonary artery catheter into clinical practice. Since then, several systems have been developed that allow for a less-invasive CO monitoring. The so-called "non-calibrated pulse contour systems" (PCS) estimate CO based on pulse contour analysis of the arterial waveform, as determined by means of an arterial catheter without additional calibration. The transformation of the arterial waveform signal as a pressure measurement to a CO as a volume per time parameter requires a concise knowledge of the dynamic characteristics of the arterial vasculature. These characteristics cannot be measured non-invasively and must be estimated. Of the four commercially available systems, three use internal databases or nomograms based on patients' demographic parameters and one uses a complex calculation to derive the necessary parameters from small oscillations of the arterial waveform that change with altered arterial dynamic characteristics. The operator must ensure that the arterial waveform is neither over-nor under-dampened. A fast-flush test of the catheter-transducer system allows for the evaluation of the dynamic response characteristics of the system and its dampening characteristics. Limitations to PCS must be acknowledged, i.e., in intra-aortic balloon-pump therapy or in states of low-or high-systemic vascular resistance where the accuracy is limited. Nevertheless, it has been shown that a perioperative algorithm-based use of PCS may reduce complications. When considering the method of operation and the limitations, the PCS are a helpful component in the armamentarium of the critical care physician.
引用
收藏
页数:6
相关论文
共 40 条
  • [1] Impact of Systemic Vascular Resistance on the Accuracy of the Pulsioflex Device
    Biais, Matthieu
    Mazocky, Elodie
    Stecken, Laurent
    Pereira, Bruno
    Sesay, Musa
    Roullet, Stephanie
    Quinart, Alice
    Sztark, Francois
    [J]. ANESTHESIA AND ANALGESIA, 2017, 124 (02) : 487 - 493
  • [2] Goal-directed haemodynamic therapy during elective total hip arthroplasty under regional anaesthesia
    Cecconi, Maurizio
    Fasano, Nicola
    Langiano, Nicola
    Divella, Michele
    Costa, Maria G.
    Rhodes, Andrew
    Della Rocca, Giorgio
    [J]. CRITICAL CARE, 2011, 15 (03):
  • [3] The effectiveness of right heart catheterization in the initial care of critically ill patients
    Connors, AF
    Speroff, T
    Dawson, NV
    Thomas, C
    Harrell, FE
    Wagner, D
    Desbiens, N
    Goldman, L
    Wu, AW
    Califf, RM
    Fulkerson, WJ
    Vidaillet, H
    Broste, S
    Bellamy, P
    Lynn, J
    Knaus, WA
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11): : 889 - 897
  • [4] Validation of a new arterial pulse contour-based cardiac output device
    de Waal, Eric E. C.
    Kalkman, Cor J.
    Rex, Steffen
    Buhre, Wolfgang F.
    [J]. CRITICAL CARE MEDICINE, 2007, 35 (08) : 1904 - 1909
  • [5] Radial artery pressure monitoring underestimates central arterial pressure during vasopressor therapy in critically ill surgical patients
    Dorman, T
    Breslow, MJ
    Lipsett, PA
    Rosenberg, JM
    Balser, JR
    Almog, Y
    Rosenfeld, BA
    [J]. CRITICAL CARE MEDICINE, 1998, 26 (10) : 1646 - 1649
  • [6] Comparison between an uncalibrated pulse contour method and thermodilution technique for cardiac output estimation in septic patients
    Franchi, F.
    Silvestri, R.
    Cubattoli, L.
    Taccone, F. S.
    Donadello, K.
    Romano, S. M.
    Giomarelli, P.
    McBride, W. T.
    Scolletta, S.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2011, 107 (02) : 202 - 208
  • [7] Frank O., 1899, Z BIOL-MUNICH, V37, P483
  • [8] DIRECT BLOOD-PRESSURE MEASUREMENT - DYNAMIC-RESPONSE REQUIREMENTS
    GARDNER, RM
    [J]. ANESTHESIOLOGY, 1981, 54 (03) : 227 - 236
  • [9] Cardiac output monitoring by pressure recording analytical method in cardiac surgery
    Giomarelli, P
    Biagioli, B
    Scolletta, S
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 26 (03) : 515 - 520
  • [10] Gopal S, 2014, MINERVA ANESTESIOL, V80, P314