In vivo evaluation of a new hybrid graft using retrograde visceral perfusion for thoracoabdominal aortic repair in an animal model

被引:3
作者
Wipper, Sabine [1 ]
Sandhu, Harleen K. [2 ]
Kolbel, Tilo [3 ]
Estrera, Anthony L. [2 ]
Trepte, Constantin [4 ]
Behem, Christoph [4 ]
Miller, Charles C., III [2 ]
Debus, E. Sebastian [3 ]
机构
[1] Med Univ Innsbruck, Dept Vasc Surg, Anischstr 35, A-6020 Innsbruck, Austria
[2] McGovern Med Sch UTHlth, Dept Cardiothorac & Vasc Surg, Houston, TX USA
[3] Univ Heart Ctr Hamburg Eppendorf, Dept Vasc Med, Hamburg, Germany
[4] Univ Hosp Hamburg Eppendorf, Dept Anaesthesiol, Hamburg, Germany
关键词
SPIDER technique; hybrid aortic repair; Thoracoflo; thoracoabdominal aortic repair; TAAA; ANEURYSM REPAIR; OUTCOMES;
D O I
10.1016/j.xjtc.2022.07.022
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The SPIDER technique for hybrid thoracoabdominal aortic aneurysm repair can avoid thoracotomy and extracorporeal circulation. To improve technical feasibility and safety, the new Thoracoflo graft, consisting of a proximal stent graft connected to a 7-branched abdominal prosthesis, was evaluated in a pig model for technical feasibility testing, before implantation in humans. Methods: Retroperitoneal exposure of the infradiaphragmatic aorta, including visceral and renal arteries, was performed in 7 pigs (75-85 kg). One iliac branch was temporarily attached to the distal aorta to maintain retrograde visceral and an-tegrade iliac perfusion after deployment of the thoracic stent graft segment (SPI-DER technique). The proximal stent-grafted segment was deployed in the thoracic aorta via direct aortic puncture over the wire without fluoroscopy. The graft was deaired before flow via the iliac side branch to the visceral and iliac ar-teries was established. Visceral, renal, and lumbar arteries were subsequently su-tured to the corresponding side branches of the graft. Technical feasibility, operating and clamping time, blood flow, and tissue perfusion in the related organs were evaluated before implantation and after 3 and 6 hours using transit-time flow measurement and fluorescent microspheres. Final angiography or postprocedural computed tomography angiography were performed.Results: Over-the-wire graft deployment was successful in 6 animals without he-modynamic alteration (P 1/4 n.s.). In 1 pig, the proximal stent graft section migrated as the guidewire was not removed, as recommended, before release of the proximal fixation wire. Angiography and computed tomography scan confirmed successful graft implantation and transit-time flow measurement confirmed good visceral and iliac blood flow. Fluorescent microspheres confirmed good spinal cord perfu-sion.Conclusions: Over-the-wire implantation of the Thoracoflo graft using the SPIDER technique is feasible in a pig model. No fluoroscopy was required. For safe implan-tation, it is mandatory to follow the single steps of implantation. (JTCVS Techniques 2022;15:1-8)
引用
收藏
页码:1 / 8
页数:8
相关论文
共 19 条
  • [1] Open repair of intact thoracoabdominal aortic aneurysms in the American College of Surgeons National Surgical Quality Improvement Program
    Bensley, Rodney P.
    Curran, Thomas
    Hurks, Rob
    Lo, Ruby C.
    Wyers, Mark C.
    Hamdan, Allen D.
    Chaikof, Elliot L.
    Schermerhorn, Marc L.
    [J]. JOURNAL OF VASCULAR SURGERY, 2013, 58 (04) : 894 - 900
  • [2] Extent II repair of thoracoabdominal aortic aneurysm secondary to chronic dissection
    Coselli, Joseph S.
    LeMaire, Scott A.
    Weldon, Scott A.
    [J]. ANNALS OF CARDIOTHORACIC SURGERY, 2012, 1 (03) : 394 - 397
  • [3] Reversed Frozen Elephant Trunk Technique to Treat a Type II Thoracoabdominal Aortic Aneurysm
    Debus, E. Sebastian
    Koelbel, Tilo
    Wipper, Sabine
    Diener, Holger
    Reiter, Beate
    Detter, Christian
    Tsilimparis, Nikolaos
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2017, 24 (02) : 277 - 280
  • [4] Feasibility Study of a Novel Thoraco-abdominal Aortic Hybrid Device (SPIDER-graft) in a Translational Pig Model
    Debus, Eike S.
    Koelbel, Tilo
    Dupree, Anna
    Daum, Guenter
    Sandhu, Harleen L.
    Manzoni, Daniel
    Wipper, Sabine H.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2018, 55 (02) : 196 - 205
  • [5] The SPIDER Graft: A New Hybrid Device for Thoraco-abdominal Aortic Repair
    Debus, Eike Sebastian
    Koelbel, Tilo
    Wipper, Sabine
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2019, 57 (04) : 588 - 588
  • [6] Outcomes of Open Repair for Chronic Descending Thoracic Aortic Dissection
    Estrera, Anthony L.
    Jan, Azam
    Sandhu, Harleen
    Shalhub, Sherene
    Medina-Castro, Mario
    Nguyen, Tom C.
    Azizzadeh, Ali
    Charlton-Ouw, Kristofer
    Miller, Charles C.
    Safi, Hazim J.
    [J]. ANNALS OF THORACIC SURGERY, 2015, 99 (03) : 786 - 794
  • [7] Pulmonary complications after descending thoracic and thoracoabdominal aortic aneurysm repair: Predictors, prevention, and treatment
    Etz, Christian D.
    Di Luozzo, Gabriele
    Bello, Ricardo
    Luehr, Maximilian
    Khan, Muhammad Z.
    Bodian, Carol A.
    Griepp, Randall B.
    Plestis, Konstadinos A.
    [J]. ANNALS OF THORACIC SURGERY, 2007, 83 (02) : S870 - S876
  • [8] Preoperative percutaneous coronary intervention in patients undergoing open thoracoabdominal and descending thoracic aneurysm repair
    Girardi, Leonard N.
    Rabotnikov, Yury
    Avgerinos, Dimitrios V.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 147 (01) : 163 - 168
  • [9] VALIDATION OF FLUORESCENT-LABELED MICROSPHERES FOR MEASUREMENT OF REGIONAL ORGAN PERFUSION
    GLENNY, RW
    BERNARD, S
    BRINKLEY, M
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (05) : 2585 - 2597
  • [10] Outcomes after thoracoabdominal aortic aneurysm repair using hypothermic circulatory arrest
    Kouchoukos, Nicholas T.
    Kulik, Alexander
    Castner, Catherine F.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (03) : S139 - S141