Pulsed Eddy Current Response to General Corrosion in Concrete Rebar

被引:6
作者
Eddy, Ian [1 ]
Underhill, P. R. [2 ]
Morelli, J. [1 ]
Krause, T. W. [2 ]
机构
[1] Queens Univ, Dept Phys Engn Phys & Astron, 99 Univ Ave, Kingston, ON K7L 3N6, Canada
[2] Royal Mil Coll Canada Kingston, Dept Phys & Space Sci, 13 Gen Crerar Crescent, Kingston, ON K7K 7B4, Canada
来源
JOURNAL OF NONDESTRUCTIVE EVALUATION, DIAGNOSTICS AND PROGNOSTICS OF ENGINEERING SYSTEMS | 2020年 / 3卷 / 04期
基金
加拿大自然科学与工程研究理事会;
关键词
concrete rebar inspection; general rebar corrosion; pulsed eddy current; electromagnetic testing; continuous and periodic condition assessment; eddy current; electromagnetics; structural engineering; testing methodologies;
D O I
10.1115/1.4047851
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Corrosion of carbon steel rebar in concrete structures, such as highway bridges and buildings, has a direct impact on their structural integrity since the rebar provides the tensile strength within the structure. Rebar strength depends on the remaining effective radius of a given rod. Long-time decay up to 0.1 s, in the transient response of pulsed eddy current (PEC), was examined as a potential method to quantify general corrosion in ferromagnetic rebar. The transient response of a coaxial solenoidal drive-receive coil pair, oriented parallel to the rebar axis, was analyzed over a range of distances into the concrete (liftoff) and rebar radii. At long times, the single exponential decay constant was largely independent of liftoff. A power law relationship for the characteristic decay time, consistent with long-time diffusion of electromagnetic fields into a rod, was observed. The intercept of a best-fit line to measured voltage decay decreased exponentially with liftoff and maintained a measurable response up to 110 mm distance for a 25 mm (1 in.) diameter rebar. This exponential decay was present in 22 mm (7/8 in.), 19 mm (3/4 in.), and 15 mm (5/8 in.) samples as well. Reported results demonstrate the potential for PEC to quantify remaining cross-sectional area of rebar in concrete structures.
引用
收藏
页数:5
相关论文
共 35 条
[1]  
Alberta C., 2016, A Guide for Durable Residential Concrete Flatwork 2016 Revision
[2]  
[Anonymous], 2020, Advantages and Disadvantages of Hydrogen Energy | Boiler Guide
[3]   EDDY-CURRENT METHOD FOR MEASURING THE RESISTIVITY OF METALS [J].
BEAN, CP ;
DEBLOIS, RW ;
NESBITT, LB .
JOURNAL OF APPLIED PHYSICS, 1959, 30 (12) :1976-1980
[4]  
Boysen Earl., 2011, NANOTECHNOLOGY DUMMI, V2nd
[5]   Pulsed Eddy Current Inspection of Support Structures in Steam Generators [J].
Buck, Jeremy A. ;
Underhill, Peter Ross ;
Mokros, Sarah G. ;
Morelli, Jordan E. ;
Babbar, Vijay K. ;
Lepine, Brian ;
Renaud, Joe ;
Krause, Thomas W. .
IEEE SENSORS JOURNAL, 2015, 15 (08) :4305-4312
[6]  
Cecco V. S., 1981, AECL 7523, V1, P163
[7]  
Corrosionpedia, 2018, REB CORR
[8]   Transient response of a driver-pickup coil probe in transient eddy current testing [J].
Desjardins, D. ;
Krause, T. W. ;
Clapham, L. .
NDT & E INTERNATIONAL, 2015, 75 :8-14
[9]  
Desjardins D., 2015, Analytical Modeling for Transient Probe Response in Eddy Current Testing, P1
[10]   Pulsed Eddy Current Response to Liftoff in Different Sizes of Concrete Embedded Rebar [J].
Eddy, I. C. ;
Underhill, P. R. ;
Morelli, J. ;
Krause, T. W. .
2019 IEEE SENSORS, 2019,