Ex vivo surface and mechanical properties of coated orthodontic archwires

被引:79
作者
Elayyan, Firas
Silikas, Nick [2 ]
Bearn, David [1 ]
机构
[1] Univ Dundee, Sch Dent, Dundee DD1 4HN, Scotland
[2] Univ Manchester, Sch Dent, Manchester M13 9PL, Lancs, England
关键词
D O I
10.1093/ejo/cjn057
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study examined the mechanical and physical properties of retrieved coated nickel-titanium (NiTi) archwires compared with unused samples. Ultraesthetic (TM) 0.016 inch coated archwires (G & Wire Company) were investigated. Ten as-received wires were subjected to a three-point bending test using conventional and self-ligating bracket systems. Surface roughness of the coating was measured with a contact stylus profilometer. Optical and scanning electron microscopes were used to assess surface topography. Ten archwires were used in vivo for a period of between 4 and 6 weeks. Retrieved archwires were subjected to the same tests. The percentage of the remaining coating was calculated using digital photography. Coated archwires were used in vivo for a mean period of 33 days. Differences between the mean values of the as-received and retrieved archwires were determined using t-tests. In the three-point bending test, with conventional elastomeric ligation, retrieved wires produced a lower unloading force (P < 0.001). Both retrieved and as-received coated archwires produced zero values of unloading force when deflected for 4 mm. When tested using a self-ligating bracket system, retrieved and as-received coated archwires produced the same amount of force (P > 0.05). With surface profilometry, all measured roughness parameters (except R-sm) had greater surface roughness for the retrieved coated archwires (P < 0.05). Under microscopy, retrieved coated archwires showed discolouration, ditching, and delamination. Only 75 per cent of the coating was present in retrieved coated archwires. Retrieved coated archwires produced lower unloading force values than as-received coated archwires with conventional ligation. Surface roughness of coated archwires increased after use. Coated archwires have a low aesthetic value, with 25 per cent of the coating lost within 33 days in vivo.
引用
收藏
页码:661 / 667
页数:7
相关论文
共 17 条
  • [1] Surface roughness of orthodontic wires via atomic force microscopy, laser specular reflectance, and profilometry
    Bourauel, C
    Fries, T
    Drescher, D
    Plietsch, R
    [J]. EUROPEAN JOURNAL OF ORTHODONTICS, 1998, 20 (01) : 79 - 92
  • [2] Surface characterization of retrieved NiTi orthodontic archwires
    Eliades, T
    Eliades, G
    Athanasiou, AE
    Bradley, TG
    [J]. EUROPEAN JOURNAL OF ORTHODONTICS, 2000, 22 (03) : 317 - 326
  • [3] The frictional behavior of coated guiding archwires
    Husmann P.
    Bourauel C.
    Wessinger M.
    Jäger A.
    [J]. Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2002, 63 (3): : 199 - 211
  • [4] MECHANICAL-PROPERTIES AND CLINICAL-APPLICATIONS OF ORTHODONTIC WIRES
    KAPILA, S
    SACHDEVA, R
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1989, 96 (02) : 100 - 109
  • [5] Krishnan V, 2004, ANGLE ORTHOD, V74, P825
  • [6] EFFECTS OF SURFACE-ROUGHNESS ON THE COEFFICIENTS OF FRICTION IN MODEL ORTHODONTIC SYSTEMS
    KUSY, RP
    WHITLEY, JQ
    [J]. JOURNAL OF BIOMECHANICS, 1990, 23 (09) : 913 - 925
  • [7] Kusy RP, 1997, ANGLE ORTHOD, V67, P197
  • [8] KUSY RP, 1988, ANGLE ORTHOD, V58, P33
  • [9] Lim K. F., 1994, Clinical Materials, V16, P63, DOI 10.1016/0267-6605(94)90099-X
  • [10] THE SUPER-ELASTIC PROPERTY OF THE JAPANESE NITI ALLOY WIRE FOR USE IN ORTHODONTICS
    MIURA, F
    MOGI, M
    OHURA, Y
    HAMANAKA, H
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1986, 90 (01) : 1 - 10