Low Radiation Dose with Triple-Rule-Out CT Angiography in Diagnosis of Acute Chest Pain

被引:0
作者
Liu, Jianhua [1 ]
Huang, Sa [1 ]
Zhang, Jichang [2 ]
Yuan, Qinghai [1 ]
机构
[1] Ji Lin Univ, Hosp 2, Dept Radiol, Changchun, Peoples R China
[2] Ji Lin Univ, Hosp 2, Dept Cardiol, Changchun, Peoples R China
关键词
Acute chest pain; CT Angiography; Triple-rule-out; Radiation dose; ECG-gating; Pitch; EMERGENCY-DEPARTMENT PATIENTS; TOMOGRAPHY CORONARY-ANGIOGRAPHY; TUBE CURRENT MODULATION; DUAL-SOURCE CT; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; MYOCARDIAL-INFARCTION; MULTISLICE CT; RECONSTRUCTION; RISK;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Acute chest pain (ACP) is one of the most common reasons in adults regarding visits to the emergency department (ED). The triple-rule-out CTA (TRO CTA) is feasible to evaluate ACP in the ED and potentially lead to earlier triage. However, just a few patients with ACP were evaluated with the protocol of TRO CTA, one of the major reasons which preclude the TRO CTA to be a routine diagnostic tool is the associated radiation dose. Herein we review the variety of techniques which can reduce the radiation dose during TRO CTA. With reasonable application of those techniques, the radiation dose can be reduced obviously, and the patients suffered from ACP will benefit from TRO CTA with techniques of reducing radiation dose.
引用
收藏
页码:47 / 50
页数:4
相关论文
共 50 条
  • [1] Triple-Rule-Out CT Angiography for Evaluation of Acute Chest Pain and Possible Acute Coronary Syndrome
    Halpern, Ethan J.
    RADIOLOGY, 2009, 252 (02) : 332 - 345
  • [2] Triple-rule-out dual-source CT angiography of patients with acute chest pain: Dose reduction potential of 100 kV scanning
    Krissak, Radko
    Henzler, Thomas
    Prechel, Anne
    Reichert, Miriam
    Gruettner, Joachim
    Sueselbeck, Tim
    Schoenberg, Stefan O.
    Fink, Christian
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (12) : 3691 - 3696
  • [3] Estimation of radiation exposure of retrospective gated and prospective triggered 128-slice triple-rule-out CT angiography
    Ketelsen, Dominik
    Fenchel, Michael
    Thomas, Christoph
    Buchgeister, Markus
    Boehringer, Nadine
    Tsiflikas, Ilias
    Kaempf, Michael
    Claussen, Claus D.
    Heuschmid, Martin
    ACTA RADIOLOGICA, 2011, 52 (07) : 762 - 766
  • [4] ‘Triple-rule-out’ CT angiography for clinical decision making and early triage of acute chest pain patients: use of 320-multislice CT angiography
    Eltabbakh A.R.
    Dawoud M.A.
    Langer M.
    Moharm M.A.
    Hamdy E.A.
    Hamisa M.F.
    Egyptian Journal of Radiology and Nuclear Medicine, 50 (1)
  • [5] Evaluation of Acute Chest Pain in the Emergency Department "Triple Rule-Out" Computed Tomography Angiography
    Yoon, Yeonyee E.
    Wann, Samuel
    CARDIOLOGY IN REVIEW, 2011, 19 (03) : 115 - 121
  • [6] Residents' Performance in the Interpretation of On-Call "Triple-Rule-Out" CT Studies in Patients with Acute Chest Pain
    Garrett, K. Gabriel
    De Cecco, Carlo N.
    Schoepf, U. Joseph
    Silverman, Justin R.
    Krazinski, Aleksander W.
    Geyer, Lucas L.
    Lewis, Alex J.
    Headden, Gary F.
    Ravenel, James G.
    Suranyi, Pal
    Meinel, Felix G.
    ACADEMIC RADIOLOGY, 2014, 21 (07) : 938 - 944
  • [7] Diagnostic performance of a low dose triple rule-out CT angiography using SAFIRE in emergency department
    Si-Mohamed, S.
    Greffier, J.
    Bobbia, X.
    Larbi, A.
    Delicque, J.
    Khasanova, E.
    Beregi, J. -P.
    Macri, F.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2017, 98 (12) : 881 - 891
  • [8] Contrast material and radiation dose reduction strategy for triple-rule-out cardiac CT angiography: feasibility study of non-ECG-gated low kVp scan of the whole chest following coronary CT angiography
    Kidoh, Masafumi
    Nakaura, Takeshi
    Nakamura, Shinichi
    Namimoto, Tomohiro
    Nozaki, Toshimitsu
    Sakaino, Naritsugu
    Harada, Kazunori
    Yamashita, Yasuyuki
    ACTA RADIOLOGICA, 2014, 55 (10) : 1186 - 1196
  • [9] Coronary CT angiography in emergency department patients with acute chest pain: triple rule-out protocol versus dedicated coronary CT angiography
    Lee, Hwa Yeon
    Yoo, Seung Min
    White, Charles S.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (03) : 319 - 326
  • [10] Low-dose triple-rule-out using 320-row-detector volume MDCT - less contrast medium and lower radiation exposure
    Durmus, Tahir
    Rogalla, Patrik
    Lembcke, Alexander
    Muehler, Matthias R.
    Hamm, Bernd
    Hein, Patrick A.
    EUROPEAN RADIOLOGY, 2011, 21 (07) : 1416 - 1423